Cryostat Microm HM550 - 388114
To avoid condensation the sliding window is heated when closed. Page 121. 121. Thermo Fisher Scientific. Operation Manual HM550. The microtome
Thermo Scientific Microtome Cryostat Microm HM 525
Only skilled or specially trained personnel must operate the microtome cryostat i.e. placing the specimen onto a chuck
MICROTOME CRYOSTAT HM 525 INSTRUCTION MANUAL
Only skilled or specially trained personnel must operate the microtome cryostat i.e. placing the specimen onto a chuck
Cryostar NX70 Brochure
comfort. confidence. Page 2. Thermo Scientific. CryoStar NX70 Cryostat. Innovative Design.
INSTRUCTION MANUAL MICROTOME CRYOSTAT HM 500 OM
The cryostat has a cooling system to control the temperature of the working area of the microtome and knife carrier as well as to cool the freezing stations for
MICROTOME CRYOSTAT HM 550 Series Options O M V P D
Via a set value input for the specimen head on the control panel the electronics control the thermo-electrical element at any desired temperature between +10°C
Thermo Fisher
ii the microtome must be correctly adjusted and operated. iii This Section lists all the reagents that Thermo specify can be used with the Cryotome cryostat.
Document Number: SuRF-HIS-004.02 Title: Cryostat-Microtome Use
2014. 2. 19. The purpose of this Standard Operating Procedure (SOP) is to describe the current procedure for cryostat-microtome use cleaning and ...
A novel method of sample homogenization with the use of a
2019. 11. 20. microtome-cryostat (Thermo Scienti c USA) cooled to À16. C. (Fig. 1). A piece of a cold sample (2–5. C) was placed on a top of the disc and ...
Cryostat Microm HM550 - 388114
Thermo Fisher Scientific. Operation Manual HM550. Microm HM550. Thermo Scientific. CRYOSTAT MICROTOM incl. options O M V P D. Operation manual – English.
Thermo Scientific Microtome Cryostat Microm HM 525
part of Thermo Fisher Scientific. Otto-Hahn-Str. 1A. 69190 Walldorf / Germany. 387 779 - English. 1. Thermo Scientific. Microtome Cryostat. Microm HM 525.
Thermo Scientific Cryostat Series
Open-top cryostat achieves chamber temperature of -35ºC. • Stainless steel microtome with cross-roller bearings for horizontal/vertical specimen movements.
Thermo Scientific Microtome Cryostat Microm Cryo-Star HM 560
Robert-Bosch-Str. 49. 69190 Walldorf / Germany. 387 500 - English. 1. Thermo Scientific. Microtome Cryostat. Microm Cryo-Star HM 560. INSTRUCTION MANUAL
Thermo Scientific CryoStar NX50 Operator Guide 388149 Issue 2.0
This document is designed for use with the Thermo Scientific CryoStar NX50 cryostat also referred to as the CryoStar NX50 throughout this Guide.
M45010 HM525 NX Brochure .pdf
Intuitive user interface. • Enhanced ergonomics. Thermo Scientific HM525 NX. Cryostat The front of the microtome is a new design which.
Cryostar NX70 Brochure
Thermo Scientific. CryoStar NX70 Cryostat. Innovative Design. • Unique – Rapid Response Temperature Control adjusts quickly to settings changes and
Disposable Blades for Cryostats - Low-Profile Blades
Disposable Blades for Cryostats. MX35 Ultra™ Low-Profile Blade Blades designed for use with cryostats. ... Shandon Premium Disposable Microtome Blades.
MICROTOME CRYOSTAT HM 550 Series Options O M V P D
Avoid permanent touching of metal parts inside the cryostat microtome chamber as frostbite may occur at A thermo-electrical element is coupled with the.
shandon-cryotome-fse-manual.pdf
Welcome to the Thermo Electron Corporation Shandon. Cryotome FE and FSE cryostats. They are designed for the routine sectioning of quick-frozen tissue
![Thermo Scientific Cryostat Series Thermo Scientific Cryostat Series](https://pdfprof.com/Listes/27/16574-27Cryostat_Brochure.pdf.pdf.jpg)
Thermo Scientic Cryostat Series
Clinical/Research/Industrial
World-Class Sections
Unmatched Ergonomics
Leading-Edge Safety
HM 525HM 550 Cryotome FE/FSEHM 560
Recommended UseClinicalClinical/ResearchClinical/ResearchResearch/IndustrialDisinfection UV*
Disinfection
Delivery System*Formalin
Fumigation Disinfection
Delivery System*
Temperature
Controls
€ Chamber€ Peltier€ Chamber€ Peltier€ Object*€ Chamber€ Cryobar€ Object**€ Peltier€ Object€ Knife
Freezing Stations271282
Touch-Screen OperationNoNoYesNo
Motorized handwheelNoYes*NoYes
Overview
of CryostatFeatures
*Optional **FSE only 2The Clinical Environment
The clinical environment is extremely stressful. The average cost of the surgical suite is $20...30 per minute and the College of American Pathologists (CAP) mandates the production of a frozen section slide within eight minutes. The most intuitive user interfaces, accelerated freezing capabilities and leading-edge disinfection systems enable even the most pressured staff member to easily obtain great frozen sections.The Research Environment
High sample volumes and extreme versatility
mean that the cryostat becomes an extension of the user. The ability to handle small samples and esoteric specimens is critical to the researcher.Best-in-class ergonomics, unmatched precision
and reliability, as well as leading-edge safety features ensure that even the most demanding research requirements are fulfilled.Unique Solutions for Unique
Demands in Clinical
and Research LaboratoriesThermo Scientic Microm HM 525
No-stress, intuitive frozen sectioning for the mid-size clinical laboratory is the distinction of the HM 525. Leading-edge precision, an exceptionally smooth handwheel, innovative safety features and unmatched design enable clinicians to deliver at a moments notice.Clinical
Physical SpeciÞcations
Dimensions without handwheel (D x W x H):
30" x 25" x 47" (76 x 64 x 120cm)
Weight: 275lb. (125kg)
Tissue Type Chamber Temp. (°C)
Unìxed Tissue
Brain -12
Liver -14
Lymph Nodes -14
Kidney -16
Spleen -16
Muscle -20
Tissue Type Chamber Temp. (°C)
Unìxed Tissue
Thyroid -20
Skin -25
Breast -25
Breast with Fat -30 or below
Adipose Tissue -30 or below
Fixed Tissue -12 to -17
Suggested Cutting Temperatures for Frozen Tissue
UV Option
Choose any time between
0-300 minutes.
Turn the dial and walk away.
The 36W UV light source does the rest.
1 1 2 2 3 3 3Intuitive, no-stress sectioning
Immediately recognizable controls and
clear, uncluttered design make rapid frozen sections possible without delay.Leading-Edge Precision
A Peltier to -60°C and a cryochamber
reaching -35°C ensure optimal sectioning temperatures. Stepper motor technology and an extra wide anti-roll plate facilitate consistent, artifact-free frozen sections.Safety Without Doubts
A UV option enables surface disinfection
of harmful bacteria, viruses and spores.Automatic specimen retraction and a
mechanical handwheel lock ensure safe chamber access. 4The HM 550 Chamber
Twelve specimen stage stations,
including four cooling to -60ºC.Object cooling head for
independent specimen control to -50ºC.Vacutome gently pulls sections
under the anti-roll plate creating reproduciblewrinkle-free sections. 2 2 5 1 1 3 4Thermo Scientic Microm HM 550
The HM 550 provides a perfect solution for high volume, demanding clinical and research environments.Clinical/Research
3Best-in-Class Sectioning
The Automatic Cryo Approach (ACA)
advances specimens to the knifes edge and stepping motor technology delivers more consistent sections.With a patented vacutome to "atten
sections, Peltier and cryochamber temperature from 0...35°C, best-in-class sectioning is ensured.Low-Fatigue Ergonomics
The HM 550 allows users to sit or stand
and operate controls on the left and right of the arm rests.A convenient LCD display, movable
chamber illumination to reduce glare and the ability to motorize sectioning by foot or hand reduce the fatigue associated with other cryostats.Unmatched Protection
User safety and infection control permeate
the HM 550. The specimen holder always stops in the down position for unimpeded access to the tissue section and an emergency stop is accessible by either foot or control panel.The unique debris removal system and
state-of-the-art disinfection system ensure user safety. 5Debris removal system eliminates
unwanted debris to create a cleaner, safer environment.Disinfection delivery
system "oods the chamber with a3...5 micron mist, disinfecting even
remote areas. 4 5Ergonomically designed control panelsGraphical LCD Menuindicates section count, remaining travel in microns,
number of sections, trim and "ne section thickness and retraction fun ction.Selectable
cutting windowAutomatic Cryo
Approach System (ACS)
quotesdbs_dbs2.pdfusesText_2[PDF] cryptocom coin
[PDF] crystal field theory pdf
[PDF] cse 2221 github
[PDF] cse 2221 osu reddit
[PDF] cse 2221 project 10
[PDF] cse 2221 sequence
[PDF] cse 2221 syllabus
[PDF] cse 2231
[PDF] cse 2321
[PDF] cse2221 homepage
[PDF] cspire
[PDF] cspire customer service contact number
[PDF] cspire customer service email
[PDF] cspire customer service jobs