The KRIWAN INT511 air flow monitor controls air-flow velocities over a range of. 0.28 m/s in accordance with the calorimetric principle. The switching point ...
Functional description. The KRIWAN INT511 air flow monitor monitors air flow speeds in the range of 0.2-8m/s according to the calorimetric principle (with
Jun 23 2003 flow monitor is used to monitor air flows in ventilation and air- conditioning systems
Der KRIWAN INT511 Luft- stromwächter überwacht nach dem kalorimetrischen Prinzip. Luftstromgeschwindigkeiten im. Bereich von 028 m/s. Mittels eines ...
Measuring and Monitoring the Air Flow and Pressure. Sensor for recording the air currents and differential pressure in air ducts. INT511 Flow Monitors.
Apr 2 2015 INT511/24. Flow monitors with voltage-free contact outputs are used for air velocity moni- toring in ventilation and air conditioning ...
Airflow Lufttechnik. Alfa Laval. Alre-IT Regeltechnik. ARI-Armaturen. Armatherm. A-M-Systeme. B-Control. BELIMO. B.E.G.. Briem Steuerungstechnik. Bürkert.
Airflow ? Alfa Laval ? Alre ? A-M-Systeme ? Armatherm ? Ari ? Afriso schaltung auf eine DDC oder ein Monitoring-System stehen analoge 0-10V- ...
Airflow Lufttechnik. Alfa Laval. Alre-IT Regeltechnik. ARI-Armaturen. Armatherm. A-M-Systeme. B-Control. BELIMO. B.E.G.. Briem Steuerungstechnik. Bürkert.
124X1092 Guide Xhead Air &Exh Efi / Prowadnik wodzika. 124X1092 Temperature - Oil fuel
Apr 26 2019 · The KRIWAN INT511 air flow monitor controls air-flow velocities over a range of 0 2 8 m/s in accordance with the calorimetric principle The switching point can be set within the adjustment range using a built-in potentiometer (left stop corresponds to the minimum sensitivity)
INT511 Product description The KRIWAN INT511 air ? ow monitor monitors the speed of air ? ows using the calorimetric principle The sensor operates having compensated for temperature The switching point can be set/selected in the monitoring area using the inte-grated potentiometer
The KRIWAN air ? ow sensor INT510 registers the air ? ow speed and outputs an analogue temperature-compensated DC 0 10V signal for further processing Technical speci? cations Electrical connection DC 24V ±20 Permitted ambient temperature -5°C +60°C Max current consumption 25mA Sensing range 0 2 1m/s (curve A)
AIRGARD® AIR FLOW MONITORS MODELS 350-CEM AND 315-BSC SPECIFICATIONS Alnor Products TSI Incorporated Visit our website at www alnor com for more information USA Tel: +1 800 874 2811 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 P/N 5001499 Rev C ©201Printed in U S A 7 TSI Incorporated
Mount the airflow monitor by means of the mounting clamp provided Diameter of the mounting hole for the unit: 24 mm If mounting is to be airtight use the gasket provided The sensing head must be completely immersed into the airflow and should be in the range of the highest flow velocity if possible Installation depth: min 32 mm max 120 mm