MRI-Ready Systems Manual
JUDE MEDICAL Accent Accent MRI Assurity MRI Durata Ellipse Endurity Endurity MRI Fortify Assura IsoFlex Optisure Quadra Assura Quadra Assura MP Quartet Tendril Tendril MRI and the nine-squares symbol are trademarks and service marks of St Jude Medical Inc and its related companies © 2016 St Jude Medical Inc |
Users Manual
MRI Status Endurity™ Core PM1152 Single-chamber pulse generator IS-1 MR Conditional Endurity™ PM1160 Single-chamber pulse generator IS-1 Untested Endurity™ PM1162 Single-chamber pulse generator IS-1 MR Conditional Zenus™ PM1170 Single-chamber pulse generator IS-1 Untested Endurity MRI™ PM1172 Single-chamber pulse |
What is the endurity cardiac pacemaker system?
The Endurity Cardiac Pacemaker System (Models PM1162, PM2162; St. Jude Medical, Inc., St. Paul, MN) been designed and tested for performance of an MRI examination using a 1.5-T (Tesla) field-st More ... Conditional 5 More... Endurity Cardiac Pacemaker System, St. Jude Medical More...
What if the MRI settings are not enabled?
If the MRI Settings are not enabled and the patient is ready for the MRI scan, enable the settings with the handheld device. To enable the MRI Settings: 1. the handheld device over the implanted pulse generator. The handheld device should be touching the patient's clothing directly over the implanted pulse generator.
What is the MRI ready system manual?
Download the MRI Ready Systems Manual or MRI Ready Leadless System Manual to review how data will be handled by each system. The MRI parameter settings are selected at the physician's discretion. The default MRI parameter settings are automatically stored in the Abbott MR Conditional device.
What are the MRI scan parameters for St Jude Medical MR conditional system?
When performing an MRI scan on a patient with a St. Jude Medical MR Conditional system, the following scan parameters must be followed. Table 2. MRI scan parameters 1.5 Tesla/64 MHz excitation frequency (hydrogen atom). 1.5 Tesla/64 MHz excitation frequency (hydrogen atom). 1.5 Tesla/64 MHz excitation frequency (hydrogen atom).
Confirm MRI Readiness
To look up your patient’s system, use the Product Searchtool to determine whether your patient’s device and leads (if applicable) are safe for an MRI. Based on the country you select, you can choose the device and lead combination (if applicable) to get scan parameters. If a device is not shown in the list, it is not MR Conditional. Alternatively,
Select The Correct Scan Parameters
Download the MRI Ready Systems Manual or MRI Ready Leadless System Manualto check the MRI scan parameter tables for the applicable scan and identify the settings for RF Transmit Conditions and scan regions. Be sure to check the lead combination(s) (if applicable) to ensure you select the correct settings. cardiovascular.abbott
Check The MRI Settings Status
CAUTION:Do not bring any external control devices, such as the Merlin Patient Care System (PCS) Programmer, SJM MRI Activator handheld device, or AVEIR Link Module into the scanner magnet room (Zone IV). These devices are considered MR Unsafe. Download the MRI Ready Systems Manual or MRI Ready Leadless System Manualfor details about checking the MR
Perform The Scan and Monitor The Patient
Proper patient monitoring must be provided during the MRI scan. This includes continuous monitoring of the patient's hemodynamic function. Download the MRI Ready Systems Manual or MRI Ready Leadless System Manualfor additional details about patient monitoring. cardiovascular.abbott
Disable The MRI Settings
MRI Settings must be disabled by the patient's device management physician or clinician using the Merlin Programmer, and the AVEIR Link Module for leadless pacemakers. For certain pacemakers, the MRI Activator handheld device may be used. cardiovascular.abbott
Endurity MRI™ - soma medical
Endurity MRI™ Stimulateur cardiaque * Paramètres d'examen IRM SONDE MODÈLE LONGUEURS DE SONDE AIMANT SAR Sonde TENDRIL MRI™ |
Manuel dutilisation - St Jude Medical Product Manuals
Endurity PM1162 Générateur d'impulsions simple chambre IS-1 Compatible IRM sous conditions Endurity MRI PM1172 Générateur d'impulsions simple |
MRI Procedure [OUS Assurity-Endurity 3T MRI] [OUS] [v4]
MRI Procedure Information for the St Jude Medical™ MR Conditional System Device/Lead Combinations for Assurity MRI™ and Endurity MRI™ Devices |
Manuel des systèmes prêts pour lIRM - IRM Compatibilité
Tableau 3 Combinaisons sonde(s)/appareil de systèmes IRM sous conditions 3 T pour les stimulateurs Assurity MRI™ et Endurity MRI™ Modèle d'appareil |
Endurity MRI™ - Sante International
Allows patients to undergo 1 5 T or 3 T MRI scans when to pre-approved MRI settings pre- and post-MRI scan, Endurity MRI™ Pacemaker 46 x 50 x 6 20 |
Endurity MRI™ - Sante International
Allows patients to undergo 1 5 T or 3 T MRI scans when used with MRI (SJM MRI Activator™ device) can be used to program Endurity MRI™ Pacemaker |
SSED Template - FDA
The Assurity MRI and Endurity MRI pacemakers, the Tendril MRI lead, and the MRI Activator (the SJM Brady MRI System) are currently distributed commercially |
MRI-Ready Systems Manual - CARDIOVASCULAR Abbott
JUDE MEDICAL, Accent, Accent MRI, Assurity MRI, Durata, Ellipse, Endurity, Endurity MRI, Fortify Assura, IsoFlex, Optisure, Quadra Assura, Quadra Assura MP, |
PACEMAKERS
MRI Pulse Width 1,0 ms MRI Paced AV Delay 25–120 ms MRI Scan Parameters** Endurity MRI™ Single-chamber Pacemaker PHYSICAL SPECIFICATIONS |