In-Tank Return Line Filters RFM Series
LOW PRESSURE FILTERS RFM Series
X / 12 - V - - L24. Filter Type. RFM. = In-Tank Return Line Filter. Element Media. ON. = Optimicron®. |
Return Line Filter RFM with 2-Hole Mounting
MODEL CODE (also order example). 2.1. COMPLETE FILTER: TANK-TOP VERSION. Filter type. RFM. Filter material. ®. ®. Operating pressure. |
Filters for Hydraulic and Lube Oil
Return Line Mobile Indicators - I29; Differential Pressure Mobile RFM page D20. In-tank low cost high performance mobile filters – Sizes 75 90 |
HYDRAULIC AND LUBE OIL FILTERS RFM Series
RFM Series. Low Pressure In-Tank Return Line Filters – 145 psi • up to 300 gpm RFM filters are constructed of polyamide plastic housing and lid. |
Return Line Filter RFM with 2-Hole Mounting - Tank-top versions
connection for a clogging indicator. (Important: For RFM 75 to 185 please state mounting position for indicator!) 1.2 FILTER ELEMENTS. HYDAC filter elements |
Filters
Differential Pressure Indicators - H21; Return Line Mobile Indicators - H29; so that the desired filter series data sheet can be found with ease. |
Return Line Filter RFM with 2-Hole Mounting - Tank-top versions
connection for a clogging indicator. (Important: for RFM 75 to 195 please state mounting position for indicator!) 1.2 FILTER ELEMENTS. HYDAC filter elements |
Return Line Filter RFM
As tank-top or in-tank filter. 1.6 SPECIAL MODELS AND. ACCESSORIES. Connections for filling the hydraulic. ? system via return line element. (RFM 330 and |
Return Line Filter RFM with 4-Hole Mounting
Tank-top filter. 1.6 SPECIAL MODELS AND. ACCESSORIES. ? Connections for filling the hydraulic system via return line element. (RFM 330 and above). |
The NEWEST Product Offering from HYDAC Filters for Complete
accessories like gauges in-tank filters |
Return Line Filter RFM with 4-Hole Mounting
(return line indication) Pressure setting of the clogging indicator 2 bar (others on request) Bypass cracking pressure 3 bar (others on request) Symbol for hydraulic systems RFM 75 Tank-top mounted versions: up to 850 l/min up to 10 bar RFM 90 RFM 150 RFM 165 RFM 185 RFM 210 RFM 270 RFM 330 RFM 500 RFM 661 RFM 851 E 7 106 1 2/11 16 RFM 600 |
Return Line Filter RFM with 2-Hole Mounting
In-Tank Return Line Filters 145 psi • up to 224 gpm Features The compact and lightweight design make RFM filters especially suitable for mobile applications RFM filters are constructed of polyamide plastic housing and lid RFM 90/150/210/270 drop in replacement for “Tank Topper” filters |
Return Line Filter RFM with 2-Hole Mounting - HydroWhale
Return Line Filter RFM with 2-Hole Mounting 1 1 3TECHNICAL SPECIFICATIONS 1 1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations They consist of a filter head (with 2-hole flange) filter bowl and a screw-on cover plate Standard equipment: with bypass valve |
In-Tank Return Line Filters RFM Series - physicsprincetonedu
In-Tank Return Line Filters RFM Series Pressures to 145 psi • Flows to 224 gpm • Port Sizes 1” 11/ 2” and 2 1/ 2” APPLICATION • HYDAC RFM In-tank Return Line Filters are designed for use on hydraulic power units machine tools plastics injection molding equipment mobile equipment and hydraulic test equipment • These filters |
Tanktopper Series I II & III - Parker Hannifin
Tank Mounted Return Line Filters Tanktopper Series I II & III SPECIFICATION CONTINUED (D) 4xM8 (Min 100mm) (3 94) MAX OIL LEVEL Free element clearance 0 3 (H) Second port optional 111 Mounting hole +0 5 0 (Min 100mm) (3 94) MAX OIL LEVEL (0°-max 30°) 4x9 ON PITCH CIRCLE Ø145 Torque-load max 8 Nm (5 70) ISO 228 G1/ 8 (BSP) * For filter |
Return Line Filter RFM with 4-Hole Mounting - Airline Hyd
Return Line Filter RFM with 4-Hole Mounting 219 E 7 106 1 1/04 15 1 TECHNICAL SPECIFICATIONS 1 1 FILTER HOUSING Construction The fi lter housings are designed in accordance with international regulations They consist of a fi lter head (with 4-hole fl ange) fi lter bowl and a screw-on cover plate |
RFM Series - hidrafluidcom
In-Tank Return Line Filters 145 psi • up to 224 gpm Features The compact and lightweight design make RFM filters especially suitable for mobile applications RFM filters are constructed of polyamide plastic housing and lid RFM 90/150/210/270 drop in replacement for “Tank Topper” filters |
LO RESSUR ILTERS RFM Series - Airline Hyd
• RFM filters are constructed of polyamide plastic housing and lid • RFM 90/150/210/270 drop in replacement for “Tank Topper” filters • Sizes 50 - 851 aluminum alloy is water tolerant - anodization is not required for water based fluids (HWBF) |
Hydraulic Return Line Filters - Alexis Filters
RETURN FILTERS IN TANK Return Filters In Tank 51 Q Hydraulic Filters & Accessories for Mobile Engine Applications Service Indicators Performance Curves SAE Flanges PRESSURE GAUGE P171953 (500 01) Scale: -100÷500 kPa (-1÷5 bar) VISUAL PRESSURE GAUGE INDICATOR P171958 (503 01) Setting: 120 kPa (12 bar) ELECTRICAL PRESSURE SWITCH INDICATOR |
BFTTR Tank-Mounted Return Line Filters
Tank Top Return Line Filter up to 160 gpm (605 lpm)-10°F to 230°F (-25°C to 110°C) 43 5 psi (3 bar) 72 5 psi (5 bar) 145 psi (10 bar) Materials of Construction Head and Cover: Filter Bowl: Bypass Valve: Indicator Housing: Seals: Aluminum alloy BFTTR0301 1001 1002 1003 1801 Polyamide material BFTTR0111 1801A 4001 4002 4003 4003A |
Low Pressure Filters - HYDAC Technology Corporation
In-tank return filter made of polyamide-housing and plastic lid-low cost 100 (7) 100 (378) 1 1/2 S HF4R page D36 Meets HF4 automotive specs and uses industry standard-size HF4 spec elements Threaded outlet permits in-line use 145 (10) 211 (800) 3/4 - 2 1/2 S & Vac RKM page D40 Single filter functions as return line and charge pump filter in |
Searches related to in tank return line filters rfm series filetype:pdf
Series RFM = In-Tank Return Line Filter Element Media BN/HC = Betamicron ® (Low Collapse) ECO/N = ECOmicron ® (Low Collapse) MM = Mobilemicron (Low Collapse) W/HC = Wire Screen Size 75 Not available in the SET Style 165 330 500 Type of Mounting Connection S = Inside Tank with shroud for welding and spring for element hold-down |
What are the technical specifications of return line filter RFM?
- 157 E 7.106.13/03.12 Return Line Filter RFM with 2-Hole Mounting 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The ? lter housings are designed in accordance with international regulations. They consist of a ? lter head (with 2-hole ? ange), ? lter bowl and a screw-on cover plate.
What is a tank mounted return line filter?
- Tank mounted return line filter with filter element according to DIN 24550 Features The tank mounted return line filters are designed for instal- lation on fluid tanks. Their function is to separate solid materials from fluids.
What is the RFM all-plastic return line?
- The RFM All-Plastic ? lter provides a cost-effective alternative to the standard RFM product range. This ? lter is an all-plastic version with a simple hose connection as the return line port.
What are the different types of RFM filters?
- Tank-top versions: up to 200 l/min, up to 10 bar In-tank versions: up to 2,600 l/min, up to 10 bar RFM S RFM 90 RFM 150 RFM 165 RFM 185 RFM KIT RFM SET RFM SET www.comoso.com 158 E 7.106.13/03.12 2. MODEL CODE (also order example) 2.1. COMPLETE FILTER: TANK-TOP VERSION Filter type RFM Filter material of element
In-Tank Return Line Filters RFM Series - Airline Hydraulics
HYDAC RFM In-tank Return Line Filters are designed for use on hydraulic power units, machine tools, plastics injection molding equipment, mobile equipment, and hydraulic test equipment These filters are designed to be directly mounted onto the oil reservoir for filtration of solids from hydraulic fluids |
RFM Return Line Filter with 2-Hole Mounting - HYDAC
Tank breather filter built into head on RFM 75 to 195 4-hole flange (see brochure "Return Line Filter RFM with 4-hole mounting") 1 7 SPARE PARTS |
Return Line Filter RFM with 2-Hole Mounting - Comoso Controlled
Tank breather filter built into head on RFM 75 to 185 Line Filter RFM with 4- hole mounting") 1 7 SPARE series consists of a filter cover plate and element |
SPECIAL ORDER FILTERS - LOW PRESSURE RFMS & RFMSet
closed end cap of the cartridge element RFM S RFM Set Series Inside Tank Return Line Filters 145 psi • up to 132 gpm Hydraulic Symbol A B RFM S |
Return Line Filter RFM with 4-Hole Mounting - Hydac
Connections for filling the hydraulic system via return line element (RFM 330 and above) ○ Extension tube on request ○ Tank breather filter built into head on |
Return Line Filter RFM with 4-Hole Mounting - Hydac
Tank-top filter 1 6 SPECIAL MODELS AND ACCESSORIES ○ Connections for filling the hydraulic system via return line element (RFM 330 and above) |
HYDRAULIC AND LUBE OIL FILTERS RFM Series
X / 12 - V - - L24 Filter Type RFM = In-Tank Return Line Filter Element Media BN/HC = Betamicron® |
Preferred stock 12-05 - Hydraulic Controls, Inc
Indicator Trip point set to 29 PSID (2 bar) • Pressure Rating - 145 PSI RFM Series In-Tank Return Line Filters Model Code For Filter Part No Micron Rating |
Low Pressure Filters - CMA/Flodyne/Hydradyne
Low Pressure Filters INNOVATIVE FLUID POWER 62 Model Code RFM BN/ HC 330 B F F 3 D 1 X / 12 - V - - L24 Filter Type RFM = In-Tank Return Line |
LOW PRESSURE FILTERS RFM Series - PowerFlow Fluid Systems
RFM filters are constructed of polyamide plastic housing and lid RFM = In- Tank Return Line Filter Element Media ON = Optimicron® BN/HC = Betamicron ® |