[PDF] Single Phase Fixed Output Static Voltage and





Previous PDF Next PDF



5 KVA Solid-state Frequency Converter - 120V 60Hz Input to 220V

Please review specifications and do not order based solely on images. IND-SFC-1P-5KVA-120-60HZ-220-50HZ Frequency Converter message sales@larsonelectronics.



1 KVA Solid-state Frequency Converter - 240V 60Hz Input to 230V

1 KVA Solid-state Frequency Converter - 240V 60Hz Input to 230V 50Hz Output - 1PH - Front Contact us today at 800-369-6671 or message sales@larsonelectronics.



MILITARY & DEFENCE

150kVA Rotating Frequency Converter APOJET AJR. 10kVA Solid State Frequency 12-1500kVA 50/60Hz or 60/50Hz MG-Set. 6. Page 7. Unrivalled after sales service.



FCL-FX SERIES - THREE PHASE - 6 to over 400 kVA

CONVERTING 50 to 60Hz OR 60 to 50Hz. The FCL-3P-S10-FX range of Three Phase Static Frequency Converters /. Changers allows the connection of 60 Hz powered 



Ctg-SPF CVCF 10-1000KVA-19

50Hz ←→ 60Hz 50Hz ←→ 400Hz



UNINTERRUPTIBLE POWER SUPPLY

Possible to operate as 50Hz/60Hz Frequency Converter. Extended Back up time with External Battery Cabinet. ONLINE UPS. DSP Flexipower. 1 Phase In - 1 Phase Out 



Step Wave Converters

Since 1987 FCX Systems



FC-450

Mikasa FC-450 is the high frequency converter for Mikasa high frequency vibrators. The input power supply for this converter is three-phase 380V (50Hz) / 400V ...



Single Phase Fixed Output Static Voltage and

The FCL-S10-FX range of Single Phase Static Frequency Converters / Changers allows the connection of 60 Hz powered equipment to a 50 Hz supply and 50 Hz.



STANDARD

50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz converter from bus when not in use. K2A/K4A AUXILLIARY. With online and standby dry ...



Single Phase Fixed Output Static Voltage and

The FCL-S10-FX range of Single Phase Static Frequency Converters / Changers allows the connection of 60 Hz powered equipment to a 50 Hz supply and 50 Hz.



INGEGRID™ Shore Power Converter

referred: Shore to Ship Cold Ironing



ME1 front.eps

Sales. T : 01424 853464. All Other Departments. F : 01424 852268 ME1 Frequency Converter ... Conversion between 50Hz 60Hz and 400Hz.



UNINTERRUPTIBLE POWER SUPPLY

***Device outputs are optional please contact your sales representative. Possible to operate as 50Hz/60Hz Frequency Converter.



FR-S500 INSTRUCTION MANUAL(BASIC)

where you purchased the inverter or your Mitsubishi sales representative. To change the value to more than 60Hz <50Hz> Pr. 1 "maximum frequency".



Clippers Series 1k-10k

True double conversion. • Output power factor=1. • Output voltage regulation < 1%. • Higher output crest ratio 3:1. • 50Hz/60Hz frequency converter mode.



SAMSUNG COMPRESSOR

Domestic Sales : Tel) +82-31-8062-8177 (Fax : 9316) Inverter Rotary Compressor. 1996 ISO14001 Certified ... 220-240V ~ 50Hz 220V ~ 60Hz.



PowerProTM EF300 Series - Three Phase Input & Output Online

BPC Energy's Frequency Converters are used for converting either 50Hz 60Hz or 400Hz





Shore-To-Ship Power & Smart Ports: Portfolio Overview

Apr 19 2017 Frequency converter technology overview ... 60 Hertz. Frequency on board. 50 Hz. 60 Hz. Container (<140m) ... After sales Service.

Single Phase Fixed Output Static Voltage and

STATICFREQUENCYCONVERTERS /

CHANGERS

WITH VOLTAGE

CONVERSION OPTION

ACSINGLE PHASE

3 kVA - 100 kVA

IGBT SOLID STATE

PWM DESIGN

FIXED OUTPUT

SINGLE PHASE

2 WIRE

FCL-FX SERIES MODELS

CONVERTING50to60HzOR 60to50Hz

100 to 127V / 220 to 240V / 254 to 277V / 346V

+ 400 Hz Output Option for

Aviation & Military Applications

The FCL-S10-FX range of Single Phase Static Frequency Converters / Changers allows the connection of 60 Hz powered equipment to a 50 Hz supply and 50 Hz powered equipment to a 60 Hz supply. Where required, they can convert the supply voltage to a different voltage to match the requirement of the load. Models are also available offering a fixed 400 Hz output - as frequently required in Aviation and Military applications. In addition FCL-S10-FX Frequency Converters keep the load equipment running through utility voltage fluctuations and frequency variations, delivering a stable and clean voltage and frequency supply to the load equipment.

Built upon a dynamic platform, and

Incorporating the latest Pulse Width

Modulated (PWM) inverter and rectifier

controls, their solid-state design means that the static converter'sonly moving parts are the fans used for forced cooling the system.

FEATURES

Wide Range of Power Ratings

Uncomplicated and Simple to Use

Set-Up and Operation

Precise Output Voltage Regulation

Solid State PWM / IGBT Design

Inbuilt Overload Capability

Input & Output Circuit Breakers

Galvanically Isolated with Pure and

Stable Sine Wave Output

Front Display / Control Panel with

Parameter Metering - Output

Frequency, Voltage, Current and

Loading

Compact Floor Standing Enclosures

on Castors

Compliance with International

Standards

2 Year / 24 Month Warranty

Suitable for all load types - Resistive, Inductive & Capacitive (see Ensuring the Correct Sizing - Page 2)

FCL-FX SERIES - THREE PHASE - 3 to 100kVA

GENERAL COMMERCIAL & INDUSTRIAL PRODUCTS

FCL-FX-S10 - 2021-11

© Sinalda UK Limited -ȴE&EO.www.sinalda.com

STATICIGBTPWMDESIGN TOPOLOGY

50Hz INPUT & 60Hz OUTPUTMODELS- VOLTAGE OPTIONS

60Hz INPUT & 50Hz OUTPUTMODELS - VOLTAGE OPTIONS

A FCL-FX Series Fixed Output AC Voltage & Frequency Converter takes the electrical input power at one frequency and voltage and provides an another output voltage and frequency. By design the incoming AC Mains Utility supply is converted by a rectifier into DC. The DC is then feed into an Inverter which produces the required AC output power. The resulting stable and pure sinewave is then passed though a low distortion linear amplifier to achieve the required high power output rating. By utilising crystal oscillation the availability of enhanced frequency stability is ensured. Solid State in basic design, the only moving parts are the fans used to force cool the system.

FCL-S10

ModelInput Voltage * & FrequencyOutput Voltage * & Frequency HL-FX220V or 230V or 240V2 Wire50Hz100V or 110V or 120V or 127V2 Wire60Hz H-FX220V or 230V or 240V2 Wire50Hz220V or 230V or 240V2 Wire60Hz HHX-FX220V or 230V or 240V2 Wire50Hz254V or 265V or 277V or 346V2 Wire60Hz LH-FX100V or 110V or 120V or 127V2 Wire60Hz220V or 230V or 240V2 Wire50Hz HXH-FX254V or 265V or 277V or 346V2 Wire60Hz220V or 230V or 240V2 Wire50Hz L-FX100V or 110V or 120V or 127V2 Wire60Hz100V or 110V or 120V or 127V2 Wire50Hz *Customer to specify required Input & Output Voltage at time of ordering

ENCLOSURES-IP20INDOOR & IP54OUTDOOR

Also available as Three Phase Input / Single Phase

Output Solutions -FCL-3/1P-S10-FX Models

Indoor - IP20 Ingress Protection (Standard)Outdoor - IP54 Ingress Protection (-IP54 Option)

FCL-S10-FX Frequency

Converters presented in

endurable in robust air-cooled

IP20 (BS/EN 60529) / NEMA 1

floor standing steel cubicles, primarily intended for indoor use.

These enclosures offer

removeable panels for ease of installation and servicing and, in addition, lockable front door access is provided.

IP 54 = Dust Protected.

Limited ingress of dust

permitted, but will not interfere with operation of the equipment. Protection against water splashing from all directions. Limited ingress permitted. Models are also available offering a 400HzOutput (or alternative fixed output - 5 to 1000Hz)quotesdbs_dbs7.pdfusesText_5
[PDF] 60hz to 50hz power converter

[PDF] 60s fashion clothes

[PDF] 60x80 pole barn kit

[PDF] 613 area code coverage

[PDF] 64 bus times colchester

[PDF] 64 bus times gloucester to stroud

[PDF] 64 bus times metro transit

[PDF] 64 bus timetable bridgend

[PDF] 64 bus timetable ipswich

[PDF] 64 bus timetable middlesbrough

[PDF] 64 bus timetable winchester to alton

[PDF] 640 875 spngn1 book pdf

[PDF] 65 bus schedule pdf

[PDF] 65 bus times

[PDF] 65 rue nationale 74500 évian les bains france