SRA/SRA LT/SRA HT Ni-Cd Batteries

SRA/SRA LT/SRA HT Ni-Cd Batteries. Installation and operating instructions. A battery delivered discharged and filled may be stored for many years before it 



SRA Ni-Cd battery

SRA Saft's brand new range of Ni-Cd railway batteries for auxiliary SRA - Medium power solutions. SRA Standard. SRA LT. SRA HT. - 30°C to + 50°C.



SRA Ni-Cd battery

SRA LT enables a smaller battery size to support the required load profile in low temperatures while SRA HT offers superior.



Batteries ferroviaires Saft

Saft enrichit constamment sa gamme de batteries ferroviaires Ni-Cd et SRA. SRA LT. SRA HT. Caractéristique principale. 70 à 520 Ah. 75 à 375 Ah.



Batteries ferroviaires Saft

Saft enrichit constamment sa gamme de batteries ferroviaires Ni-Cd et SRA. SRA LT. SRA HT. Caractéristique principale. 70 à 520 Ah. 75 à 375 Ah.



Cell topping-up equipment for Ni-Cd batteries (DC)

Ni-Cd batteries (DC) Battery charger (120 / 230 V) + plugs ... SRA HT. 150 175



Batteries ferroviaires Saft

Saft enrichit constamment sa gamme de batteries ferroviaires Ni-Cd et SRA. SRA LT. SRA HT. Caractéristique principale. 70 à 520 Ah. 75 à 375 Ah.



Cell topping-up equipment for Ni-Cd batteries (AC)

Ni-Cd batteries (AC) battery. Use insulated tools. Electrolyte is harmful to skin and ... SRA HT. 150 175



Cell topping-up equipment for Ni-Cd batteries (DC)

Ni-Cd batteries (DC) battery. Use insulated tools. Electrolyte is harmful to skin and ... SRA HT. 150 175



Saft rail batteries

SRA Standard/LT/HT. MRX. Onboard. Trackside. Backup. Engine starting. Regenerative traction. Infrastructure support. Ni-Cd S / PBE block battery. Ni-Cd S 

SRA Ni-Cd battery

The medium power backup batter

y for railway applications SRA, Saft's brand new range of Ni-Cd railway batteries for auxiliary backup applications, is the latest development in our ongoing new product investment programme to meet evolving customer needs. Designed to perform in extreme conditions, SRA comes in three versions: SRA Standard for use between - 30°C to + 50°C, SRA LT for low temperatures (- 50°C to + 40°C) and SRA HT for high temperatures (- 20°C to + 65°C). Having specific ranges for cold and hot climates give the possibility to optimize the solution in extreme temperatures. SRA's optimized electrical performance, extremely compact cells and very high energy density provide the ideal basis for battery systems that are lighter in weight and occupy less onboard space. Furthermore SRA is fully compatible with Saft's well established range of standardized railway battery systems, with the same fast and easy maintenance procedures.

SRA - Performance and reliability

in desert heat or arctic cold

SRA - for when the going gets tough

SRA Ni-Cd battery - The medium power backup battery for railway applications2

Saft moves ahead

with the railway industry

Saft has over 60 years of experience

in delivering onboard energy backup solutions for railway applications with a key emphasis on reliability, safety and security. Saft's full spectrum of services range from supplying individual batteries right through to operating as a global supplier of fully integrated, turnkey battery systems for both new-build and replacement projects.

SRA - Medium power solutions

SRA Standard

SRA LT

SRA HT

- 30°C to + 50°C - 50°C to + 40°C - 20°C to + 65°C

75-375 Ah

75-375 Ah

70-350 Ah

Operating temperature rangeCapacity range

SRA Ni-Cd battery - The medium power backup battery for railway applications3

Optimize your battery's performance

for extreme temperatures Even in the most extreme conditions, SRA ensures continuous operation of auxiliary systems critical for passenger safety. •SRA are designed for discharge levels of 2C 5

A continuous

and 5C 5

A peak

•SRA's optimized performance eliminates the need to oversize the battery

Free up your onboard space

and save weight SRA's compact design provides an overall 30% reduction in volume and weight compared with a standard Ni-Cd battery. •Enables optimized system design for very high energy density •Cost benefits include more space for passengers and improved fuel efficiency due to lower overall weight

Create the ideal battery

for your specific needs SRA is highly resistant to the shocks and vibrations encountered in railway applications and offers complete flexibility in term of capacity, containers and maintenance systems. •Choose your capacity:

Single cell capacities range from 70 to 375 Ah

•Choose your container:Available in various plastic (FRpp, FR, P) and stainless steel containers •Choose your maintenance system:

Optional centralized water filling system

Standard cell design integrates perfectly

into your battery system SRA cells are a perfect match with Saft's railway battery systems. • Direct fitting within standard systems • Customized battery boxes also available Batteries can be integrated into bespoke trays designed to suit specific applications.

SRA LT

Discharge at Ccurrent rate at different temperatures C e l l v o l t a g e V

Capacity (%Cn)

1.35 1.30 1.25 1.20 1.15 1.10 1.05 1.00 0.95 0.90 0.85

0102030405060708090100110

+20°C-20°C-40°C

SRA HT

Discharge at C current rate at different temperatures C e l l v o l t a g e V

Capacity (%Cn)

1.35 1.30 1.25 1.20 1.15 1.10 1.05 1.00 0.95 0.90 0.85

0102030405060708090100110

+60°C-20°C

SRA Standard

Discharge at C current rate at different temperatures C e l l v o l t a g e V

Capacity (%Cn)

1.35 1.30 1.25 1.20 1.15 1.10 1.05 1.00 0.95 0.90 0.85

0102030405060708090100110

+40°C-20°C
2,7 3,6 3,9 4,7 4,9 6,1 6,5 7,3 8,8 10,2 10,5 11,8 12,2 307
307
307
307
307
343
343
343
343
343
343
343
343
90
90
90
91
91
170
170
170
170
170
170
170
170
SRA Ni-Cd battery - The medium power backup battery for railway applications4

SRA FRpp physical characteristics

Saft railway batteries conform to all major quality, safety and environmental standards

1/Flame arrester vent cap

2/Large electrolyte reserve

3/Sintered positive electrode

4/Separator

5/Plastic bonded negative electrode

6/Container

SRA

Standard

75
90
110
125
140
160
190
220
260
280
310
340
375
75
90
110
125
140
160
190
220
260
280
310
340
375
61
86
86
104
104
78
78
87
103
117
quotesdbs_dbs25.pdfusesText_31
[PDF] Batteries pour chaque usage et application

[PDF] batteries pour ordinateur portable - Anciens Et Réunions

[PDF] BATTERIES SHIDO LITHIUM ION - Anciens Et Réunions

[PDF] Batteries SRX Ni-Cd

[PDF] Batteries stationnaires étanches au plomb à recombinaison de - France

[PDF] batteries tableau d`affectations vl - Porsche

[PDF] batteries tashima power-plus - Anciens Et Réunions

[PDF] Batteries-ENERSYS

[PDF] Batteries… Tout l`art de stocker l`énergie - Anciens Et Réunions

[PDF] Batterietrennschalter

[PDF] batters cookie dough pâte à biscuits - Anciens Et Réunions

[PDF] Battersea Power Station FR - Gestion De Projet

[PDF] battery backup module 12/24 - Anciens Et Réunions

[PDF] Battery Backup System Système de secours à

[PDF] Battery Charger - Sterling Power Products - Le Style Et La Mode