[PDF] BD BD EmeraldTM with BD™ Blunt





Previous PDF Next PDF



BD

BD EmeraldTM with BD™ Blunt Fill Needle Pregnancy & lactation: Although no studies have been conducted no ... For general purpose use.



The goal is simple: the best possible outcome

While all of BD's regional Anaesthesia products are high quality Incidence of PDPH by needle type: BD™ Whitacre vs. ... Syringes for use with pumps.



BD

actions that combine to help us achieve our purpose of Helping all Reducing material in the BD emerald™ syringe portfolio by up to 30%1.



Prospective randomized comparison of cerebrospinal fluid

spinal anaesthesia using 27G Quincke-type needles. Notably PDPH is a common and ... A 3-ml syringe (BD Emerald™ Syringe Luer Slip



Data set compilation of Alerts and Recalls

11?/05?/2020 8. AUS. Recall 06/05/16. Philips. Electronics. Australia. Ltd. MobileDiagnost wDR 2 all software versions affected. (diagnostic x-ray system).



medichoice-catalog-2016.pdf

Single patient use. Item No. Holder Needle Webster 5 Inch Disposable Non-Sterile ... Light Examination Multi-Purpose Mobile 30 Inch Flexible Neck.



Innovation for Sustainability in Sheep and Goats

Innovation and multi-actor cross-border cooperation in central Pyrenees to improve sustainability of local sheep breeds: PIRINNOVI project – B. Lahoz 



The Essentials of Contraceptive Technology

of pregnancy for all users taken together whether or not they use the important purpose of family planning counseling is to help the.



2019 Surveys Catalog

Only the CAP makes such an extensive use of scientific committees and experts. The purpose of this study is to benchmark opioid urine drug testing ...



DESCEMET MEMBRANE ENDOTHELIAL KERATOPLASTY

WELL CONCEIVED: THE ACCESSORIES. · Low additional costs through compatible standard accessories: G-38610. SINGLE-USE SYRINGE. BD EMERALD™.

Medication Delivery Solutions

Product Catalogue

bd.com/en-uk BD is among the world's leading suppliers of medical devices and a leading innovator in medication management devices - from preparation to injection and infusion. In 1906 the Company built the first-ever facility in the U.S. to manufacture needles and syringes. In recent years - particularly given our merger with CareFusion in 2015 and Bard in 2017 - the complementary nature of BD, CareFusion and Bard capabilities make the new, combined company stronger and more relevant than ever before in medication management.

Our History

With more than 118 years of history, BD has built a strong culture of innovation that has strengthened its leadership and partnerships with healthcare facilities. A pioneer in healthcare worker safety, BD offers products featuring safety technologies to protect healthcare workers from needlestick injuries and exposure to hazardous drugs. An expert in vascular access management and care BD provides a complete and evidence-based set of solutions from catheter insertion to removal, and everything in between. To answer the needs of patients and healthcare workers BD also provides healthcare industries with the right products and solutions. We believe in quality Because you can only partner with reliable suppliers, BD has a commitment to high quality products and processes. BD has a global quality policy valid for all our manufacturing sites, design centres, legal manufacturers and sales offices. All our manufacturing sites, distribution centres, design centres and legal manufacturers are certified according to ISO 13485. Our products are designed, developed and manufactured according to worldwide standards, guidelines and legislation. Within BD we have common computerised systems for core quality processes such as document control, labelling, change control, comply surveillance, CAPA and audits. Our different product categories comply with the standard applicable to them, ISO 10555, ISO 6009, ISO 7886, and are always mentioned in the declaration of conformity of the products. The labelling complies with EN980, EN1041 and ISO 15223. The packaging of the products is developed and maintained according to ISO 11607. The design, development and manufacturing apply the risk management activities per ISO

14971 and we perform biocompatibility testing of raw

material and final product in accordance with ISO 10993.

Customer-oriented BD has Quality and Regulatory

departments to provide the mandatory support and communication.

Welcome to Medication

Delivery Solutions (MDS)

BD has one single and relentless purpose: Advancing the world of health. This is how we make a difference, this is our work and this is our passion.

Global reliability

With a global presence in more than 190 countries, BD is a reliable supplier making supply chain excellence a priority to reach delivery expectations from our customers. Our state-of- the-art plants are manufacturing thousands of different high quality products around the world.Sustainability Environmental sustainability is also a key initiative with actions intended to minimise the environmental footprint in our manufacturing. BDs environmental initiatives include the reduction of energy and water consumption, as well as hazardous and non-hazardous waste generation, and an increase renewable energy use.3Welcome to Medication and Procedural Solutions

Infection Prevention7

ChloraPrep™8

Injection - Syringes11

Syringes - 2-Piece Technology12

Syringes - 3-Piece Technology13

BD Discardit™ II - 2-Piece Syringe 14

BD Plastipak™ - 3-Piece Syringe15

BD Emerald™ - 3-Piece Syringe16

BD Plastipak™ - 3-Piece Syringe,

1 ml low dosage17

BD UniVia™ Syringes Oral / Enteral18

BD™ Convenience Pack19

Injection - Needles21

BD Microlance

TM

3-Needles23

BD Nokor™ Admix Needles24

Injection - Safety Systems26

BD™ Blunt Fill and Blunt Filter Needles28

BD Emerald

TM with BD™ Blunt Fill Needle28

BD Eclipse™ Safety Needle

with SmartSlip™ Technology29

BD Integra™ Syringes with Detachable,

Retracting Needle30

IV Catheters33

BD Vialon™ Biomaterial35

BD Instaflash™ Technology36

BD Venflon™ Peripheral

Ported IV Catheter37

BD Venflon™ Pro IV Catheter38

BD Venflon™ Pro Safety39

BD Insyte™ Peripheral IV Catheters40

BD Insyte™ Autoguard™

Peripheral Safety IV Catheters41

BD Insyte™ Autoguard™ BC

with Blood Control Technology42

BD Cathena™ Non-ported IV Catheter43

BD Saf-T-Intima™ Integrated Safety IV

Catheter System44

BD Nexiva™ Closed IV Catheter System45

BD Nexiva™ Diffusics™47

BD Angiocath™ Peripheral IV Catheter48

BD Insyte-N™ Peripheral IV Catheters49

BD Insyte-N™ Autoguard™

Peripheral Safety IV Catheters50

BD Neoflon™Peripheral IV Catheters51

BD Neoflon™ Pro Safety

Peripheral IV Catheter52

Contents

5Contents

Primary and Secondary Sets59

ARD Sets60

Needle-free IV Sets61

Basic Gravity Sets62

Flow Controller IV Sets65

Open/Pressure Sets66

Secondary Sets67

Burette Sets68

Blood Sets69

Irrigations Sets70

Extension Sets and

Accessories72

DI Range - Macrobore PVC73

DH and DP Range73

PA Range - Macrobore PVC74

PB Range - Macrobore PE/PVC74

PE Range - Macrobore PVC-free75

Extension Sets Light Resistant75

Syringe Pump Extenstion Sets76

TIVA Sets77

Long Extension Sets78

Short Extension Sets79

BD Connecta™ Stopcocks80

3V Stopcocks80

In-line Filters81

Caps82

Accessories83

Needle-free Connectors85

BD Q-Syte™87

SmartSite™87

MaxZero™ 88

NeutraClear™89

Arterial Catheters54

BD Insyte-A™ Arterial Catheter55

BD™ Arterial Cannula with

BD Flowswitch™ One-Way Stopcock55

BD™ Arterial Needle

for Seldinger Technique56

BD™ Single Wall Puncture (M/P)

Procedure Needle57

Speciality Products104

Regional Block Needles105

Specialty Needle105

Quincke Intradiscal Needle105

Catheta Tray105

Hazardous Drugs

Safety Systems107

BD PhaSeal

™108

Texium™1116Contents

Disinfecting Caps91

BD PureHub™92

Pre-filled Flushing Syringe

for Vascular Access94

BD PosiFlush™ Pre-filled Flushing Syringes95

Anaesthesia Systems97

BD™ Whitacre Pencil-Point Spinal Needles98

BD™ Quincke Spinal Needle100

BD™ Quincke Spinal Needle Introducers 101

Tuohy and Tuohy Weiss Epidural Needles102

Infection Prevention

bd.com/en-uk

BD ChloraPrep

TM Cutaneous solution licensed for disinfection of the skin prior to invasive medical procedures

Sterile antiseptic solution containing a combination of 2% Chlorhexidine gluconate in 70% Isopropyl alcohol

Clear or Tinted (Orange) - In the tinted solution, sterile dye E110 (Sunset Yellow) is introduced upon activation

Different sized applicators for different procedures, both surgical and vascular Flow control helps prevent pooling and promotes even distribution Manufactured sterile - both the solution and applicator are sterile

Single use applicators designed to facilitate proven back and forth application technique, whilst maintaining user asepsis

(ANTT Sterile sponge, designed for comfort, with minimal dermal abrasion8Infection Prevention

FREPP 1.5ml

SEPP 0.67ml

9Infection Prevention

Product CodeSizeCoverageTint/ClearUnits/ BoxNHS Supply Chain code

270449SEPP .67ml5cm x 8cmClear200 applicatorsMRB302

270299FREPP 1.5ml10cm x 13cmClear20 applicatorsMRB303

260407I1.5ml10cm x 13cmClear25 applicatorsMRB561

2704003ml15cm x 15cmClear25 applicatorsMRB306

2704153ml15cm x 15cmTint25 applicatorsMRB494

27070010.5ml25cm x 30cmClear25 applicatorsMRB304

27071510.5ml25cm x 30cmTint25 applicatorsMRB495

27080026ml50cm x 50cmClear1 applicatorMRB305

27081526ml50cm x 50cmTint1 applicatorMRB496

BD ChloraPrep

TM

Applicators

Prescribing Information:

ChloraPrep™ & ChloraPrep with Tint 2% chlorhexidine gluconate w/v / 70% isopropyl alcohol v/v cutaneous solution. Refer to the Summary of Product Characteristics before prescribing.

Presentation:

ChloraPrep

- each applicator contains 0.67ml, 1ml, 1.5ml, 3ml, 10.5ml or 26ml of 20 mg/ ml chlorhexidine & 0.70 ml/ml isopropyl alcohol; ChloraPrep with Tint - each applicator contains 3ml, 10.5ml or 26ml of 20 mg/ml chlorhexidine & 0.70 ml/ ml isopropyl alcohol.

Indication:

Disinfection of skin prior to invasive medical

procedures. Dosage & administration: Applicator volume dependent on invasive procedure being undertaken. May be used for all age groups and patient populations. Use with care in newborn babies and those born prematurely. Applicator squeezed to break ampoule and release antiseptic solution onto sponge. Solution applied by gently pressing sponge against skin and moving back and forth for 30 seconds. The area covered should be allowed to air dry.

Contra-

indications: Patients with known hypersensitivity to ChloraPrep or ChloraPrep with Tint or any of its components, especially those with a history of possible

Chlorhexidine-related allergic reactions.

Warnings and precautions:

Solution

is ?ammable. Do not use electrocautery procedures or other ignition sources until dry. Remove any soaked materials before proceeding with the intervention. Do not use in excessive quantities, allow to pool in patient skin folds or drip on materials in contact with patient skin. Ensure no excess product is present prior to application of occlusive dressing. For external use only on intact skin, do not use on open skin wounds or broken or damaged skin. Over-vigorous use on fragile or sensitive skin or repeated use may lead to local skin reactions. Avoid prolonged skin contact. Avoid contact with eyes, mucous membranes, middle ear and neural tissue. Chlorhexidine may induce hypersensitivity, including generalised allergic reactions and anaphylactic shock. Chlorhexidine-containing products are known causes of anaphylactic reactions during anaesthesia. The symptoms of anaphylactic reactions might be masked in an anesthetized patient. If symptoms of an anaphylactic reaction are detected during anaesthesia, chlorhexidine related allergic reaction should be considered. When chlorhexidine-related allergic reaction during anaesthesia is suspected, other products containing chlorhexidine used during anaesthesia (e.g. IV lines) should be removed. Special precaution should be taken to avoid patient exposure to any other product containing chlorhexidine during the course of the treatment. May cause chemical burns in neonates, with a higher risk in preterm infants and within the rst 2 weeks of life.

Pregnancy & lactation:

Although no studies have been conducted, no eects are anticipated as systemic exposure is negligible. Undesirable e?ects:

Very rare; allergic or irritation skin reactions to chlorhexidine, isopropyl alcohol or sunset yellow (E110, present in ChloraPrep with Tint only), including erythema, rash, pruritus and blisters or application site vesicles, other local symptoms have included skin burning sensation, pain and in?ammation. Frequency not known; hypersensitivity including anaphylactic shock, dermatitis, eczema, urticaria, chemical burns in neonates, eyes irritation, hyperaemia, impaired vision, chemical burn and eye injury. Discontinue use at the rst sign of local skin reaction. Cases of anaphylactic reactions have been reported during anaesthesia. Description of selected adverse reactions: There have been isolated spontaneous reports of generalised allergic reactions potentially associated with ChloraPrep solution and have been reported during anaesthesia. In some cases, the patient may have had a pre-existing sensitivity to chlorhexidine. This product may cause a severe allergic reaction. Symptoms may include wheezing/diculty breathing, shock, facial swelling, hives, or rash. Use of ChloraPrep is contra-indicated where patients have shown previous hypersensitivity to chlorhexidine or isopropyl alcohol (see Section Contra-indications). If hypersensitivity or an allergic reaction occurs, stop use and seek medical help right away.

Per applicator costs

(ex VAT) ChloraPrep: 0.67ml (SEPP) - UK £0.30, Ireland €0.39; 1.5ml (FREPP) - UK £0.55, Ireland €0.64; 1.5ml - UK £0.78, Ireland €0.94; 3ml; 3ml - UK £0.85, Ireland €1.06; 10.5ml - UK £2.92, Ireland €3.79; 26ml - - UK £6.50, Ireland €7.96. ChloraPrep with Tint: 3ml - UK £0.89, Ireland €1.09; 10.5ml - UK £3.07, Ireland €3.88; 26ml - UK £6.83, Ireland €8.19 Legal category: UK: GSL. Ireland: Not subject to medical prescription.

Marketing Authorisation Numbers:

ChloraPrep, (UK: PL05920/0002-001;

Ireland: PA2287/001/002) & ChloraPrep with Tint, (UK: PL05920/0003-0001;

Ireland: PA2287/001/001)

Marketing Authorisation Holder:

UK : Becton

Dickinson UK Ltd, 1030 Eskdale Road, Winnersh, Wokingham RG41 5TS, United Kingdom. Ireland : Becton Dickinson France, 11 Rue Aristide Bergès, 38800 Le

Pont de Claix, France

Date of Revision:

May 2020.

Reporting suspected adverse reactions is important to monitor the benet/risk balance of the medicinal product. Reporting forms and information can be found at www.mhra.gov.uk/yellowcard (for UK) and www.hpra.ie (for Ireland). Adverse events should also be reported to BD Freephone number:

For UK

0800 0437

546 or email: CareFusionGB@professionalinformation.co.uk.

For Ireland

: +353

01 4287895/7896 or email: CareFusionIE@professionalinformation.co.uk

bd.com/en-uk

© 2020 BD. BD and the BD Logo are trademarks of Becton, Dickinson and Company.0000CF03715 Issue 1, June 2020

1030 Eskdale Road, Winnersh Triangle, Wokingham, RG41 5TS

BDUK_CustomerService@bd.com

0800 917 8776

Injection - Syringes

bd.com/en-uk 12

Syringes - 2-Piece Technology

Injection - Syringes

2-Piece Design

To ensure leak tightness, the

syringe plunger has a larger diameter than the barrel. At the same time, the syringe barrel has to have thin wall technology to be ?exible enough to accommodate the plunger movement. This requires precision molding of barrel and plunger. The resin formulation used for the barrel is self-lubricating so there is no need for additional lubrication with silicone oil.Graduations

Scale markings typically in

cubic centimetres (cc) or millilitre (ml) units. These units of measure are equivalent.Barrel

Reservoir for holding

liquid, clearly graduated to allow accurate and visual measurement of the syringe contents.Flanges

The “wings" that jut out from

the side of the syringe barrel providing an area or surface for the index nger and middle nger to grasp during aspiration or administration.

Thumb Press

The clinician presses to

push the plunger rod down into the barrel to expel its content

Plunger Rod

A piston-like device

inside the barrel

Concentric Luer Slip Tip:

A friction-t connection that

requires the clinician to insert the tip of the syringe into the needle hub or another attaching device in a push- and-twist manner. This will ensure a connection that is less likely to detach. Simply sliding the attaching device onto the syringe tip will not ensure a secure tting. The anatomy of a 2-piece syringe (without stopper)

Eccentric Luer Slip Tip:

Allows for work requiring closer

proximity to the skin. Generally used for venipunctures and aspiration of ?uids. Also see luer slip instructions. 13

Syringes - 3-Piece Technology

Injection - Syringes

Latex Free Stopper

Prevents leakage of

medication around the plunger and acts as an indicator for measuring the syringe contents (see diagram).Graduations

Scale markings typically in

cubic centimetres (cc) or millilitre (ml) units. These units of measure are equivalent.

On insulin syringes, however,

graduations are displayed in

“units" based on the insulin

concentration prescribed. (Example: U-100 means 100 units of insulin suspended within 1 ml of ?uid. A

3/10 ml insulin syringe will

accommodate up to 30 units when using U-100 insulin).Barrel

Reservoir for holding

liquid, clearly graduated to allow accurate and visual measurement of the syringe contents.Flanges

The “wings" that jut out from

the side of the syringe barrel providing an area or surface for the index nger and middle nger to grasp during aspiration or administration.

Thumb Press

The clinician presses to

push the plunger rod down into the barrel to expel its content

Plunger Rod

A piston-like device

inside the barrel

The anatomy of a 3-piece syringe (with stopper)

Eccentric Luer Slip Tip:

Allows for work requiring closer

proximity to the skin. Generally used for venipunctures and aspiration of ?uids. Also see luer slip instructions.Luer Lock Tip:

Generally used for injections

requiring a secure connection of the syringe to another device. The tip is threaded for a “locking" t, and is compatible with a variety of needles, catheters and other devices.Concentric Luer Slip Tip:

A friction-t connection that

requires the clinician to insert the tip of the syringe into the needle hub or another attaching device in a push- and-twist manner. This will ensure a connection that is less likely to detach. Simply sliding the attaching device onto the syringe tip will not ensure a secure tting.Catheter Tip:

Used for ?ushing (cleaning)

catheters, gastrostomy tubes and other devices. Insert catheter tip securely into catheter or gastrostomy tube.

If leakage occurs, refer to your

facility"s guidelines. • Transparent barrel for good visualization of syringe content

Smooth plunger movement, reduced sliding force

Leak-tight

Accurate graduation suited to user's needs

Retaining ring to prevent accidental plunger rod

withdrawal

Design of finger grip flanges ensures stability

and comfort during injection

Ergonomically designed plunger for single-handed

operation

Sterile, single-use

Natural Rubber Latex is not part of the material

formulation

BD Discardit

II - 2-Piece Syringe

Product CodeCapacity (ml)TipScale (ml)Units/ BoxNHS Supply

Chain Code

3009282Luer slip concentric0.1100FWC247

quotesdbs_dbs25.pdfusesText_31
[PDF] BD Enfants - Activités et sorties du Clas Inserm de Lille - Généalogie

[PDF] BD et dessin vectoriel

[PDF] BD et écologie : une bibliographie - Blog des bibliothèques de Saint - Anciens Et Réunions

[PDF] BD Fr - Morris - Lucky Luke - T70

[PDF] BD Jeunesse - MAIRIE DE FIXIN

[PDF] bd JEUX

[PDF] BD LIGUE DU 19 10 2015 - Terre de Handball – Hauts de France - Conception

[PDF] BD Multimédia - France

[PDF] Bd Périphérique Pte de Vincennes

[PDF] BD PosiFlush - Help Médical

[PDF] BD PRODUCT

[PDF] BD Tryptic Soy Broth (TSB)

[PDF] BD-FIL 2014 - Horaires des dédicaces du vendredi 12 septembre - Festival

[PDF] BD-jeunesse_2015-04

[PDF] BD-S1065_FICHE:Mise en page 1