[PDF] Eliwell-Controller-971-.pdf PAR. DESCRIPTION. RANGE AP1 AP2





Previous PDF Next PDF



eliwell id 971 eliwell id 971

ELIWELL ID 971. INSTRUKCJA OBSŁUGI I MONTAŻU. PRZYCISKI I ICH FUNKCJE. Przycisk "GÓRA". Przycisk "DÓŁ". Zmienia parametry i zwiększa ich wartości. Uruchamia 



Electronic controllers for refrigerating units 961 - 971 - 974 Electronic controllers for refrigerating units 961 - 971 - 974

ELIWELL CONTROLS SRL reserves the right to make any changes or improvements ID971 & ID974: 2 NTC / PTC (Default) input (programmable by parameter H00).



ID 971 LX eng bis ID 971 LX eng bis

Warning: check the power supply specified on the instrument label; for relay and power supply capacities contact the Sales. Office). ID 971 LX. 3/6. Invensys 



ID 971 eng

Warning: check the power supply specified on the instrument label; for relay and power supply capacities contact the Sales. Office). ID 971. 2/4. WWW.100Y.COM.



ID 971 fra

Consulter le. Service commercial pour obtenir les débits des relais et alimentations. ID 971 ID 971 - 230 V. A. Schéma de connexion. Invensys Controls Italy ...



ID 971 LX

www.eliwell.eu · ID 971 LX. Single stage controller for temperature. The ID 971 controllers are devices suitable for applications on normal or low temperature 



ID 971

ZUGANG ZU DEN MENÜS UND. BENUTZUNG. Die Programmierung des Instruments ist in. Menüs organisiert zu denen man gelangt wenn die Taste „set“ gedrückt und 



ID 971 Single stage controller for temperature

Eliwell France. 310 boulevard Charles de Gaulle 92390 Villeneuve la Garenne



ID 971 spa

ACCESO Y USO DE LOS MENÚS. La programación del instrumento está organizada por menús a los cuales se accede presionando y soltando rápida-.



ID 971 LX

Eliwell Controls srl ????????? ?? ????? ????? ??????? ????? ????????? ????????????? ??? ??????????????? ????????? ??? ?????? ?? ?? ??????????????. ??????? 



ID 971

ID 971. Moscow office. 1/5. ID 971. ??????????? ?????????? ??? ???????????. ????????? ? «?????????????? ???????». ????????? ????????????.



ID 971 LX

ID 971 LX. Moscow office. 1/7. ID 971 LX. ??????????? ?????????? ??? ???????????. ????????? ? «?????????????? ???????». ????????? ????????????.



ID 971 eng

Warning: check the power supply specified on the instrument label; for relay and power supply capacities contact the Sales. Office). ID 971. 2/4. WWW.100Y.COM.



Electronic controllers for refrigerating units 961 - 971 - 974

(* Pb2 is only present on models ID971 and ID974) This manual and its contents remain the sole property of ELIWELL CONTROLS SRL and shall not be ...



ID 971 fra 4-2002.pdf

ACCES ET UTILISATION DES MENUS. Les ressources sont organisées sous la forme d'un menu auquel on accède en tenant enfoncée et en relâchant immédia-.



Eliwell-Controller-971-.pdf

PAR. DESCRIPTION. RANGE AP1 AP2 AP3 AP4 M.U.. Set Temperature control Setpoint. LSE HSE 00 0



EWPlus 961/971/974

(exclusively using Eliwell NTC probes). NOTE: The technical specifications given in this document regarding measurement (range accuracy



ELIWELL – ID 971 / ID 971 LX h?tésvezérl? - Használati utasítás

ELIWELL – ID 971 / ID 971 LX h?tésvezérl?. Használati utasítás. A FELHASZNÁLÓI BILLENTY?ZET (INTERFÉSZ). A felhasználónak egy kijelz? és négy nyomógomb áll 



??? «????? ???»

??????????? ?????????? - Eliwell ID 971 LX. 1.2.2 ??????????? ?????? ??????? ????????? ? ??????? 1. ??????? 1 - ??????????? ?????? ?????? ???????-?.

Controller 971

Technical Information

www.axair-refrigeration.co.uk

01782 618 444

sales@axair-refrigeration.co.uk

IDPlus

971 devices are controllers with 2 relay outputs, 2 temperature sensors (regulation

and evaporator), a multifunctional Digital/Temperature input and a digital input.

IDPlus 971 User Interface

IDPlus 971

The relay output can be used to control:

STANDBY (ESC)

Pres

s and releaseReturns to the previous menu levelConfirms parameter valuePress for at least 5 secActivates the Standby function(when outside the menus)

UP Pres

s and releaseScroll menu itemsIncreases valuesPress for at least 5 secActivates the Manual Defrost function

DOWN Pres

s and releaseScroll menu itemsDecrease valuesPress for at least 5 sec Function can be configured by the user

SET (ENTER)

Pres

s and releaseDisplays alarms (if active)Opens Machine Status menuPress for at least 5 secOpens Programming menuConfirm commands

KEYS set set

Reduced SET / Economy LED

Flashing: economy Setpoint active

Quic k flashing: access to level2 parameters

Off: otherwise

Compressor LED

Per manently on: compressor activeFlashing:a delay, a protection or a locked start-upOff: otherwise

Alarm LED

Per manently on: alarm active

Flashing: alarm acknowledged

Off: otherwise

°C LED

Per manently on: °C setting (dro =0)

Off: otherwise

°F LED

Per manently on: °F setting (dro =1)

Off: otherwise

LEDs

Defrost LED

Per manently on: defrost active

Flashing: manual or D.I. activation

Off: otherwise

Fans LED

Per manently on: fans active

Off: otherwise

Aux LED

Per manently on: Aux output active

Flashing:manual or D.I. activation of

Deep

Cooling

* When switched on, the device performs a Lamp Test; the display and LEDs will flash for several seconds to check that they

all function correctly.* To activate the LOC function: - enter the "Basic Commands" menu by pressing the key set press keys and within 2 seconds. If

the LOC function is Active and you try to enter the "Programming" menu, the text LOC appears. If this happens, the

parameters

are still displayed but cannot be edited. To disable the keypad lock, repeat the aforementioned procedure.

compressor- defrost heating elements- evaporator fans- AUX output- temperature alarm- Standby The second probe can be used to control the defrost cycle and the evaporator fans. The

Digital inputs (D.I.1 and D.I.2) can be used for:

Energy saving- Defrost activation

AUX management- door switch- Standby- external alarm- Deep Cooling- pressure switch

HACCP alarms

Controller 971

Technical Information

www.axair-refrigeration.co.uk

01782 618 444

sales@axair-refrigeration.co.uk

AP3AP1AP2

AP4

Evaporator

T.E.V.Pb1

Ambient

Valve

Compressor

Pb2

Evaporator

T.E.V.Pb1

Ambient

Valve

Compressor

Evaporator

T.E.V.Pb1

Ambient

Valve D.I.1

Compressor

Pb2

Evaporator

T.E.V.Pb1

Ambient

Valve

Compressor

External Alarm

InternalBuzzer

Ambient= AmbientValve= Valve

Evaporator= EvaporatorCompressor= Compressor

Internal Buzzer= Internal BuzzerT.E.V.= Thermostatic Expansion Valve

External

Alarm= External Alarm

PAR.DESCRIPTIONRANGEAP1AP2AP3AP4M.U.

SetTemperature control Setpoint.LSE ... HSE

0,00,00,00,0°C/°F

COMP

RESSOR ("CP" folder)

Difdifferential. Compressor relay activation differential.0,1...30,0

2,02,02,02,0°C/°F

HseHigher Set. Maximum value that can be assigned to the Setpoint.LSE...30299,099,099,099,0°C/°F

LseLower Set. Minimum value that can be assigned to the Setpoint.-58.0...HSE-50,0-50,0-50,0-50,0°C/°F

OspTemperature value to be added to the Setpoint if reduced set enabled(Economy function).-30,0...30,03,03,00,03,0°C/°F

HcControl mode. C (0) = Cold; H (1) = Hot.C/HCCCCflag

OntController on time for faulty probe.If Ont = 1 and OFt = 0, the compressor remains on;if Ont =1 and OFt >0 it runs in duty cycle mode.0 ... 2500000min

OftController off time for faulty probe.If OFt = 1 and Ont = 0, the controller remains off;if OFt = 1 and Ont >0, it operates in duty cycle mode.0 ... 2501111min

DonCompressor relay activation delay after request0 ... 2500000secs DofDelay after switching off and subsequent activation0 ... 2500000min DbiDelay between two consecutive compressor activations0 ... 2500000min Odo(!)Delay in activating outputs after the instrument is switched on or after a power failure . 0 = not active.0 ... 250

0000min

DcsDeep Cooling cycle Setpoint.-58,0...3020,00,00,00,0°C/°F

TdcDeep Cooling cycle duration.0 ... 2550000min

DccDefrost activation delay after a Deep Cooling cycle.0 ... 2550000min

DEFROST ("dEF" folder)

Dty

Type of defrost.0 = electrical defrost; 1 = reverse cycle defrost;2 = defrost independent of compressor.0/1/2

0000num

DitInterval between the start of two consecutive defrost cycles.0 ... 2506666hours

TABLE OF 'INSTALLER' MENU PARAMETERS (IDPlus 971)

Controller 971

Technical Information

www.axair-refrigeration.co.uk

01782 618 444

sales@axair-refrigeration.co.uk

PAR.DESCRIPTIONRANGEAP1AP2AP3AP4M.U.

Dct Sele ct ion o

f count mode for the defrost interval.0 = compressor running time; 1 = appliance running time;2 = A defrost cycle is run at each compressor stop.0/1/21111num

DohDelay for start of first defrost after request.0 ... 590000min DetDefrost timeout; determines the maximum defrost duration.1 ... 25030303030min DstDefrost end temperature - determined by the evaporator probe.-50,0...1508,050,08,050,0°C/°F Dpo De

termines whether the instrument must enter defrost mode at start-up.n (0) = no; y (1) = yes.n/ynnnnflag

FANS ("FAn" folder)

Fst Fans stop temperature.-58,0...30250,050,050,050,0°C/°F FadFan activation differential.1,0 ... 50,02,02,02,02,0°C/°F FdtFan activation delay after a defrost cycle.0 ... 2500000min

DtCoil drainage time.0 ... 2500000min

Dfd Allo ws evaporator fan exclusion to be selected or not selected during defrosting. y (0) = yes (fans excluded); n (1) = no (it depends on FCO parameter).n/yyyyyflag Fco Sele ct

s or deselects fan deactivation at compressor OFF.0 = fans off; 1 = fans active; 2 = duty cycle.0/1/20000num

FonFans ON time in day duty cycle.0 ... 990000min

FofFans OFF time in day duty cycle.0 ... 990000min FnnFans ON time in night duty cycle.0 ... 990000min FnfFans OFF time in night duty cycle.0 ... 990000min EsfNight mode activation. n (0) = no; y (1) = yes.n/ynnnnflag

ALARMS

("AL" folder) Att Can be used to select absolute (Att=0) or relative (Att=1) values for HAL and LAL para meters.

0/10000num

AfdAlarm differential.1,0 ... 50,02,02,02,02,0°C/°F HalMaximum temperature alarm.LAL...30250,050,050,050,0°C/°F LalMinimum temperature alarm.-58.0...HAL-50,0-50,0-50,0-50,0°C/°F PaoAlarm exclusion time after re-activation following a power failure.0 ...

100000hours

DaoTemperature alarm exclusion time after defrost.0 ... 9990000min

PAR.DESCRIPTIONRANGEAP1AP2AP3AP4M.U.

quotesdbs_dbs1.pdfusesText_1
[PDF] eliwell id974 notice

[PDF] eliwell id974 parameters

[PDF] eliwell idplus 961

[PDF] eliwell idplus 961 mode d'emploi

[PDF] eliwell idplus 971

[PDF] eliwell idplus 974 manual

[PDF] elle kennedy the score pdf

[PDF] ellis island immigration histoire

[PDF] eloge de la folie citations

[PDF] elstat ems 55 advanced manual français

[PDF] elstat ems 55 coca cola

[PDF] em lyon alternance

[PDF] email english pdf

[PDF] email professionnel en anglais exemple

[PDF] email without knowing the name