[PDF] EXD-SH1/2 Controller with ModBus communication capability for





Previous PDF Next PDF



Universal Driver Module EXD-U02 for Electrical Control Valves EX4

Emerson Climate Technologies GmbH EX4-6. 2…5. CV4-6. 2…5. EX7. 4…5. CV7. 13…15. EX8. 6…8 ... und drücken Sie sie nach unten und hinten bis.



EC3-332 Coldroom Controller and ECD-001 Display Unit

Unit. Emerson Climate Technologies GmbH www.emersonclimate.eu EX4…EX8 Electrical Control Valves a liquid line solenoid valve is not needed to.



Electrical Control Valves EX4-8

EX4. EX5. EX6. EX7. EX8. Maximum working pressure PS. 90 bar (uni-flow) EX4-8. Emerson Climate Technologies GmbH www.emersonclimate.eu.



EXD-SH1/2 Controller with ModBus communication capability for

Emerson Climate Technologies GmbH 0 = EX4-6(FLR) 1 = EX7(FLR) 2 = EX8 ... Temperature control function is possible only with EX4-8 series valves.



Electronic Expansion Valves EX4-7-…FLR Versions Released for

Emerson Climate Technologies GmbH EX4-7-…FLR are stepper motor driven valves for precise control of ... Einbauposition waagrecht bis zu senkrechter.



Alco Controls

Pulse Modulated Expansion Valve 8. EX4 .. EX8. Electrical Control Valves. 11. EXD-U. Stand-alone Univ. tool can be downloaded from www.emersonclimate.



EC3-332 Kühlstellenregler und ECD-001 Anzeigeeinheit

Emerson Climate Technologies GmbH für EX4…EX8 Elektrische Regelventile. ECD-001 Anzeigeeinheit ... Imbusschraube solange weiterdrehen bis Halterung.



OPERATING INSTRUCTIONS Universal Driver Module EXD-U02 for

Emerson Climate Technologies GmbH control valves series EX4-8 and CV4-6. ... Closing time (sec.) EX4-6. 2…5. CV4-6. 2…5. EX7. 4…5. -. -. EX8. 6…8.



General Product Guide 2012 General Product Guide 2012

Emerson Climate Technologies - European Headquarters - Pascalstrasse 65 - 52076 Aachen for the EX4 to EX8 range of electrically driven control valves.



Alco Controls

tighter temperature control wider range of operating Electrical Control Valves Series EX4



Operating instructions Electrical Control Valves EX4-8

Las EX4-8 son válvulas de motor paso a paso que aseguran En aplicaciones de válvula de expansión y inyección de - a la máxima presión de trabajo del sistema en el el control preciso del flujo refrigerante en sistemas de líquido: resto de aplicaciones refrigeración aire acondicionado bombas de calor y - La válvula debe ser instalada tal y como



EX4-EX8 Electrical Control Valve EX Valves & Controls - Emerson

• Full travel time: EX4-EX6: 1 5 seconds EX7: 3 2 seconds EX8: 5 2 seconds The EX4-EX8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems Multifunction capability as expansion valve hot gas bypass suction gas throttlinghead pressure liquid line actuator and other



Images

Phase current operating EX4/EX5/EX6: 500mA max-10 EX7: 750mA ±10 EX8: 800mA ±10 Holding current EX4/EX5/EX6: 100mA EX7: 250mA EX8: 500mA Nominal input power per phase EX4/EX5/EX6: 3 5W EX7/EX8: 5W Dimensions (mm) Valve Type B C D E H1 EX4-I21 8 45 55 11 113 EX4-M21 8 45 55 11 113 EX4-U31 11 55 55 11 113



Electrical Control Valves EX4/EX5/EX6/EX7/EX8 - Copeland

EX4/5/6/7/8 are stepper motor driven valves for precise control of refrigerant mass flow in refrigeration air conditioning heat pumps industrial cooling process and close control systems as: Expansion valves Liquid injection for subcooling and desuperheating Capacity control: hot gas bypass regulator Capacity control: suction pressure regulator

[PDF] EXA Français admission 2015

[PDF] EXA PRO CONCOURS CONDITIONS ET EPREUVES PERMIS DE

[PDF] EXACOMPTA PL Verkauf - Anciens Et Réunions

[PDF] ExaControl 7 - Saunier Duval - Électricité

[PDF] Exacontrol E7 - Saunier Duval - Électricité

[PDF] Exacontrol7 radio

[PDF] Exact Côte d`Azur - Gestion De Projet

[PDF] EXACT MOVE T-SHIRT SANS MANCHES

[PDF] EXACTA ARMOIRES DE SECURITE - Anciens Et Réunions

[PDF] exacta serie efo - France

[PDF] exagan

[PDF] Exage 2500 FD - Rapala France - France

[PDF] exagon-Erhebung: Anforderungsmanagement bei den IT

[PDF] Exalead - Atelier TM

[PDF] EXALG020 – Mons, questions-types, 2000-2001