[PDF] Compact Merlin Gerin - 80 to 3200 A





Previous PDF Next PDF



Catalogue 2018 Circuit breakers and switch-disconnectors from Catalogue 2018 Circuit breakers and switch-disconnectors from

The launch of Schneider Electric Compact NS in 1994 revolutionized the world of molded case circuit breakers 1600...3200. Compact NS630b to 1000 N/L. NS1250 ...



Catalogue 2019 Circuit breakers and switch-disconnectors from

The launch of Schneider Electric Compact NS in 1994 revolutionized the world of molded case circuit breakers 1600...3200. Compact NS630b to 1000 N/L. NS1250 ...



Sisältö

c Compact NS 1600 – 3200 A kiinteä asennus etuliittimin ja manuaalinen 81 Compact NS Schneider Electric. LukituksetLukitus ”avoimeen” asentoon takaa ...



AA MG pricing.book

For information and availability contact your nearest Square D/Schneider Electric sales office. Compact® NS100/160/250 Circuit Breakers. Page 80. 79. DE2.



PowerPact™ M- P- and R-Frame

https://docs.natlswgr.com/docs/W1000972.pdf



AA MG pricing.book

For information and availablility contact your nearest Square D/Schneider Electric sales office. ➃ 100% rated. Compact® Circuit Breakers. UL 489 Listed ...



CBS Safe®

Merlin Gerin/Schneider Type Compact NS. 39. RRS-3 DB-50. Westinghouse Type DB Schneider Electric/Square D in 2017. BATTERY/POWER SOURCE: Li Metal Battery.



Выпуск № 18 - Типовые схемы АВР с применением

Автоматический ввод резерва разработан на базе автоматических выключателей производства Schneider Electric на токи: b 100 630 А на аппаратах серии Compact NS; b 



PowerPact™ M- P- and R-Frame

https://media.distributordatasolutions.com/schneider/2016q2/2d0aeb2cff689c4101ae9751d6000860ec329ff9.pdf



Masterpact NT ? NW

???????? ????? Schneider Electric ? Energy University ??????????? Schneider b ???????????-????????????? (Compact NSX Masterpact & PowerPact Family);.



Compact Merlin Gerin - 80 to 3200 A

Compact NS. Schneider Electric. 1. New Compact NS setting the standard



?????? ? 18 - ??????? ????? ??? ? ???????????

???????????? Schneider Electric ?? ????: b 100 630 ? ?? ????????? ????? Compact NS; b 630 1600 ? ?? ????????? ????? Masterpact NT; b 1600 3200 ? ?? 



?????? ? 18 - ??????? ????? ??? ? ???????????

???????????? Schneider Electric ?? ????: b 100 630 ? ?? ????????? ????? Compact NS; b 630 1600 ? ?? ????????? ????? Masterpact NT; b 1600 3200 ? ?? 



Compact Merlin Gerin

Merlin Gerin. ?????????????? ??????????? ? ??????????? ???????? ??????????? Compact NS ???? L (150 ... 1600 - 3200. 3200 - 6400 ????????.



PowerPacT™ M- P- and R- Frame

https://media.distributordatasolutions.com/schneider_synd/2021q4/documents/3f1a98599a0c98e6c40291c4f03af35a98ec0297.pdf



?????????????? ??????????? ? ??????????? ???????? ???????

Compact Merlin Gerin. 80 - 1250 A. ??????? ??????????? Compact NS ???? L (150. ??) ?????p????? ? ????? ?? ??p???? ... 1600 - 3200. 3200 - 6400 ????????.



Sisältö

Compact NS. Schneider Electric. 4 pushtotrip compact. NS 250 L. Ui750V Uimp8kV c Compact NS 1600 – 3200 A kiinteä ... MERLIN GERIN compact.



Compact NSX 100 - 630 ?

??????????? ????? ????? Compact NSX ??? ? ?? ???????????????



PowerPact™ M- P- and R-Frame

https://cdn.kyklo.co/assets/W1siZiIsIjIwMTkvMDMvMTEvMDcvNDUvMTQvZjIzZTZhOWQtYjI3MC00OGM3LTg4YWYtNjNlOWRlNTgxYjA5L1NjaG5laWRlciUyMEVsZWN0cmljJTIwMDYxMkNUMDEwMVIwMTA3JTIwLSUyMFBvd2VyUGFjdCUyME0sJTIwUCwlMjBSJTIwTUNDQnMlMjAtJTIwQ2F0YWxvZy5wZGYiXV0?sha=bd5e675917ec3a2b

LV power air circuit breakers

and switch-disconnectors

Compact Merlin Gerin

80 to 3200 A

Catalogue

2005

We do more with electricity

As standards, specifications and designs change from time to time, please ask for confirmation of the information given iin this publication ce document a ŽtŽ imprimŽ sur du papier Žcologique.

000000000 © 2000 Schneider Electric - All right reserved

BTP550E04-00

This document has been printed on ecological paper

Schneider Electric Industries SA

5, rue Nadar

92506 Rueil-Malmaison Cedex France

Tel : +33 (0)1 41 29 82 00

Fax : +33 (0)1 47 51 80 20

http://www.schneiderelectric.com

Design: Schneider Electric - AMEG

Photos: Schneider Electric

Printed:

Compact NS Schneider Electric1

New Compact NS,

setting the standard, once again...

The launch of Merlin Gerin Compact NS in 1994

revolutionised the world of moulded-case circuit breakers. Innovative, flexible and attractive, Compact NS rapidly set the standard in its field. Today, Schneider Electric continues to innovate, extending the Compact NS range to high power ratings to offer a comprehensive and consistent range from 80 to 3200 A. Equipped with the new generation of Micrologic control units, Compact NS630b to 3200 circuit breakers integrate electrical measurement and analysis functions. The communications option makes it possible to control power consumption, simplify maintenance and improve operating comfort. A wide range of optimised auxiliaries and accessories is also available to meet the needs of even more applications. Compact NS, simply a step aheadÉCompact NS 100 to 250 A

Compact NS 400 to 630 A

Compact NS 630 to 1600 ACompact NS 80 A046751045345053100

Compact NS 1600 to 3200 A

Things

will never be the same colibrisE45151

E45178

Compact NS Schneider Electric2

MG

Earth-leakage protection p. xx

E44357

Additional earth-leakage protection protects life and property against the risks of faulty insulation in the installation. Depending on the circuit breaker, earth-leakage protection is provided by: c adding a Vigi module to the circuit breaker c using a specific Micrologic control unit c using a Vigirex relay and separate toroids.

Compact NS,

even more applications... push to trip

Protection for:

c distribution systems supplied by transformers c distribution systems supplied by engine generator sets c long cables in IT and TN systems.

Installation :

c in power switchboards c on symmetrical rails (see page xx)

Special applications:

c 1000 V distribution systems (see page xx) c 400 Hz distribution systems (see page xx) c single-phase and two-phase systems (see page xx) c DC systems (see page xx). All circuit breakers in the Compact NS range offer positive contact indication and are suitable for isolation in compliance with standards IEC 60947-1 and 2.

E20999

Protection of LV distribution systems p. xx

E44356

Protection of machines p. xx

Protection of motor feeders p. xx

E26988

When combined with a motor starter, Compact NS circuit breakers protect the cables and the starter against short-circuits. Equipped with an electronic trip unit, Compact NS circuit breakers also protect the cables, starter and motor against overloads. The exceptional current-limiting capacity of Compact NS circuit breakers automatically ensures type-2 coordination with the motor starter, in compliance with standard IEC 60947-4-1. The different circuit-breaker versions in the Compact NS range are designed to meet the specific requirements of machines: c compliance with international standards IEC 60947-2 and UL 508 / CSA 22-2 No. 14 c compliance with U.S. standard UL 489 c protection against overloads and short-circuits c positive contact indication c installation in universal functional enclosures.

Compact NS Schneider Electric3

push t o trip

Switch-disconnectors p. xx

Service connection p. xx

E21272

A switch-disconnector version of Compact NS circuit breakers exists for circuit control and isolation. All the additional functions may be combined with the basic switch-disconnector function, including: c earth-leakage protection c motor mechanism c ammeter, etc. For information on other switch-disconnector ranges, see the Interpact (offering positive contact indication and visible break) and Fupact (fuse switch) catalogues. Compact NS service-connection circuit breakers are specially designed for the service-connection function: c lead seals and locking systems c tripping curves certified by utilities c fast overload curves to limit the power supplied, etc. Interpact INV switch-disconnectors offering visible break (see the corresponding catalogue) can be combined with Compact NS circuit breakers to constitute the various types of service connections and meet the needs of all installation configurations. NR Source-changeover systems p. xx (see also the "Source-changeover system" catalogue)

E32454

To ensure a continuous supply of power, some electrical installations are connected to two power sources: c a normal source c a replacement source on hand to supply the installation when the normal source is not available. A mechanical and/or electrical interlocking system between two Interpact, Compact or Masterpact devices avoids all risk of parallel connection of the sources during switching.

A source-changeover system can be:

c manual with mechanical interlocking between the devices c remote controlled when an electrical interlocking function in added c automatic when a controller is added to manage switching from one source to the other on the basis of external parameters.

E56631

UL 489 applications

Compact NS circuit breakers also meet the requirements of applications governed by standard UL 489 (see the corresponding catalogue). pushtotrip 1.523 4 5 6 8 1 0 x IrI m .63. 7. 8. 85.9
95
98
1 x InI r

STR 22 DE90105%Ir50/60Hzalarmtest

ImIr pushtotrip 1.523 4 5 6 8 1 0 x IrI m .63. 7. 8. 85.9
.9 5 98
1 x InIr

STR 22 DE90105%Ir50/60Hzalarmtest

ImIr

¿5...8

Compact NS Schneider Electric4

pushtotrip compact

NS 250 L

Ui750V Uimp8kV

Ue(V)Icu(kA)

220/240380/415440500525660/690250150

150

130705020100

cat A

Ics = 100 % Icu

IEC 947-2

UTE VDE BS CEI UNE NEMA

compact

NS 250 H

Ui750V Uimp8kV

Ue(V)Icu(kA)

220/240380/415440500525660/690250100

70
65
50
35
10 85
cat A

Ics = 100 % Icu

IEC 947-2

UTE VDE BS CEI UNE NEMA

E58549

...a solution for all installation configurations

The Compact NS range now covers all

ratings from 80 to 3200 A: c Compact NS80 to 1600 A, fixed, withdrawable, front or rear connections, manual or motorised operation c Compact NS1600 to 3200 A, fixed, front connection, manual operation. compact

NS 250 N

Ui750V Uimp8kV

Ue(V)Icu(kA)

220/240380/415440500525660/69025085

36
35
30
22850
cat A

Ics = 100 % Icu

IEC 947-2

UTE VDE BS CEI UNE NEMA

E27836E27837E27838

N: standard breaking

capacity

H: high breaking capacityL: very high breaking

capacityThe rating plates on the front panel of each device indicate the breaking capacity (N, H or L).

Total discrimination

as standard

E22051

Compact NS100 to 630

Compact NS630b to 1600

Compact NS1600b to 3200

Discrimination between Compact NS circuit breakers is total for all types of faults (overloads, high or low short- circuits) and whatever the type of trip unit used with the circuit breaker.

E58550

Service breaking capacity

Ics at 415 V

Service breaking capacity

Ics at 415 V

Service breaking capacity

Ics at 415 V.

E58551

Compact NS Schneider Electric5

Manual Compact NS250

with thermal-magnetic trip unit

047313

Compact NS800 with manual control Withdrawable Compact NS800 with electrical control

041625

quotesdbs_dbs10.pdfusesText_16
[PDF] compact sigma - Life Medical Services

[PDF] Compagnie Aparté – Le petit chat Miroir de Annette

[PDF] Compagnie des Indes - Musée de la Compagnie des Indes de Lorient

[PDF] Compagnie des Salins du Midi et des Salines de l?Est

[PDF] Compagnie des Transports Strasbourgeois - Gestion De Projet