[PDF] SL4.100 Output characteristic (typ.) 2. 4.





Previous PDF Next PDF



SL4.100

Output characteristic (typ.) 2. 4. Input voltage ACin [V]. O u tp u.



SLFLED

HIA/TP Frosted high-impact acrylic with tamper resistant screws. [3]. OPTIONS [4]. CONTROL [5]. VOLTAGE. EM/10W. 10-watt emergency battery [6].



StreamLine 4 Linear Light

To learn more about saving money and energy Go to www.tp-led.com Cut-size of linkable SL4 (N pcs) ... SL4. Products Series. StreamLine 4 Series.



INSTRUCTION MANUAL

SL4-14-0600-E. SL4-34-0600-E TP-14 for light curtains with 14 mm resolution:SLx-14-xxxx-E. TP-24 for light curtains with 24 mm resolution:SLx-24-xxxx-E.



Cryptanalysis of three matrix-based key establishment protocols

Let Tp be the BCFRX protocol under the platform group. G D SL4. recover the session key generated by Tp will also succeed in practice to recover.



Town of Raymond Maine Neighborhood Assessing Code Map

Jan 20 2006 TPS. CC. TA. CWA. PC. SH. CS. DBN. PP1. SL4. CA. CR. IP. JB2. DA. RB. CSA. PI. RA. TPA. WC. DB. PRA. MA. SC. WR. KG. TP.



contents

SL4 L1



Slide Mount 4-1/2 OD Pipe

2 PM-SL4. BASE KIT (ITEMS 3-7). 1. -. 3 PMSL.01 S-BRACKET. 2. 4.28 LBS. 4 PMSL.02 L-BRACKET. 2. 7.94 LBS. 5 GUB-4456 1/2" X 4-5/8" X 6-1/2" GALV U-BOLT KIT.



KSD-103-A KSD-103-B

Key Features: • Provide 3 switching-base network segments. • Auto MDI/MDI-X crossover function on the TP copper port. • Support IEEE 802.3x flow control for 



Safety Light Curtain

SL4-14-0210-E 210MM HEIGHT 14MM RES EDM SL4-14-0660-E = SLIM safety light curtain type 4 res=14mm h=660mm edm man/ ... TP-14 = Test piece ø 14mm.



DB THP-SL 4 englisch - Hydraulic Platform Trailers

Title: DB_THP-SL_4 englisch cdr Author: Traub Erich Created Date: 5/3/2010 1:21:56 PM



21 SL Series - Eaton

The new Eaton SL7 and SL4 stacklights provide reliable control over all key processes and machine availability Now available in two sizes 70 mm (SL7) and 40 mm (SL4) the new stacklights are engineered to keep you informed about potential material requirements downtime and hazards

sl4e100/0401211/2

Datasheet

4 A with power limitation

SL4.100

•In put: AC 230V / 115V, DC 210-375V •Ou tput: 24V / 4A •10 0 VA Limited Power Source •No switch-off at overload •Qu asi-Wide-Range Input •Ro bust mechanics and EMC •NE C Class 2 Power Supply

CUL/CSA-C22.2

EMC and

Low Volt.

UL60950 E137006

UL508 LISTED

IND. CONT. EQ.

No 950-M90

18 WM, 60°C

Directive

CB scheme

IEC60950

Input

Efficiency, Reliability etc.*

Construction / Mechanics*

*F or further information see data sheets "The SilverLine", "SilverLine Family

Branches"

Output

Start / Overload Behaviour

Input voltageAC100-120/220-240 V (swit chable), 47-63 Hz (85-132 VAC / 176-264 VAC, 210-375 VDC, see also "Output: Continuous Loading") Quasi-Wide-Range Input: With the switch in the 230V position the pow- er-supply unit operates at low and moderate loads (up to 2 A) at any in- put voltage between 95 and 264 VAC. Note: At DC input, always leave the switch in the 230V position

Input current< 2.0 A (switch in 115V p osition)

< 1.1 A (switch in 230V position) DCin at open outputtyp. 5 mA (preserves battery sources ) Inrush currenttyp. < 15 A at 264 V AC and cold start Unit is internally fused (fuse not accessible). External fuse not necessary, but recommended (common thermomagnetic 10A, B-type 'circuit- breaker' switch used anyway to fuse the input lines).

Transient

handling

Transient resistant acc. to VDE 0160 / W2

(750 V / 1.3ms), for all load conditions.

Hold-up time> 20 ms at 196 VAC, 24 V / 4 A

(see diagram overleaf)

Efficiencytyp. 88 % (230 VAC, 24 V / 4 A)

Lossestyp. 13.6 W (230 VAC, 24 V / 4 A)

Life cycle (electrolytics)The unit exclusively uses longlife electrolytics, specified for +105°C (cf. 'The SilverLine', p.2).

Housing dimensions and Weight

•W x H x D •Fr ee space for ventilation •W eight

65 mm x 124 mm x 1 02 mm (+ DIN rail)

above/below 25 mm recommended left/right 15 mm recommended 620 g

Design advantages:

•Al l connection blocks are easy to reach as mounted at the front panel. •In put and output are strictly apart from each other and so cannot be mixed up (Input below, output above).

Output voltage24 V DC +5% -1%

Output noise

suppression

Radiated EMI values below EN 61000-6-3, even

when using long, unscreened output cables.

Ambient temperature

range T amb Operation: -10°C...+70°C (>60°C Derating)

Storage: -25°C...+85°C

Deratingtyp. 3 W/K (at T

amb =+60°C...+70°C)

Voltage regulationbetter 2% Vout over all

Ripple / Noise< 25 mV

PP (2 0 MHz bandw., 50 !"measurem.)

Overvolt. protectiontyp. 29 V

Parallel operationyes

Power back immunity26 V

Front panel indicatorGreen LED on front panel,

goes out at V out < 12V

Start-up delaytyp. 0.1 s

Rise timeappr. 5-30 ms, dep ending on load

Overload behaviourUnit fulfills the requirements under Ltd. Power

Source acc. to EN60950, para. 2.11, as follows:

•P out •I out < 100 VA at all load conditions < 8 A at all load conditions

Continuous loading

(T amb = -10°C...+60°C, convection cooling), see also diagram overleaf

For start at T

amb <0°C and low input voltage, please contact PULS.

SwitchAC/DCinIout

230V176-264 V ACin4 A

95-176 V ACin3 A

210-375 V DCin4 A

150-210 V DCin3 A

100-150 V DCin2 A

115V85-132 V ACin4 A

Output is protected against short circuit, open circuit and overload.

Order information

Order numberDescription

SL4.100

SLZ01Screw mou nting set, two needed per unit

Your partner in power supply:

European

Power Supply

Manufacturers

Association

PULS GmbH

Arabellastraße 15

D-81925 München

Tel.: +49 89 9278-0

www.puls-power.com

Fax: +49 89 9278-199

Data sheet

2/2 sl4e100/040121

Bayerns Best 50

Czech 100 Best

EuropeÕs 500

Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice.

For further information, especially about

•EM C •Co nnections •Sa fety, Approvals •Me chanics and Mounting, see page 2 of the "The SilverLine" data sheet. 0 10 20 30
40
50
60
70
80
90
100

130170210 250290330

Input voltage VDCin [V]

Hold-up time [ms]

0 10 20 30
40
50
60
70
80
90
100

901101 301501701 90210230

Input voltage VACin [V]

Holdu-up time [ms]

80
81
82
83
84
85
86
87
88
89
90

123 45

Output current Iout [A]

Efficiency [%]

176 VAC

230 VAC

264 VAC

80
81
82
83
84
85
86
87
88
89
90

123 45

Output current Iout [A]

Efficiency [%]

85 VAC

115 VAC

132 VAC

0 5 10 15 20 25

024 681 0

Output current Iout [A]

Output voltage Vout [V]

UL Limited Power

Source Class 2

P max 100 W
I max < 8A

Hold-up time (min.)

Output characteristic (typ.)

2 4

Input voltage ACin [V]

Output current Iout [A]

6 2 4 6

100200300400

100200300400

Input voltage DCin [V]

switch at 115V 375
210
85
95

132264

ACin DCin switch at 230V
176

Output current Iout [A]

Output Current over Input Voltage (min.)

Efficiency (min.)

Iout=2A

Iout=3A

Iout=4A

Iout=2A

Iout=3A

Iout=2A

Iout=3A

Iout=4A

switch pos. 115V
switch pos. 230V

DCinACin

sledrw1/0401141/2

Datasheet

Mechanics

SL2.5/ SL5/ SL10

•In novative DIN-Rail mount, unit holds even at vibration or lateral pressure •Cl early arranged and user oriented •La rge, robust screw terminals •Se aled metal housing •Fi ne ventilating grid

Order information

Order numberDescription

SL2.100

SL2.103

SL5.100

SL5.102

SL5.105

SL5.300

SL10.100 and SL10.105

SL10.101

SLZ01

24V/2.5A

12-15V/40W

24V/5A

24-28V/120W

24-28V/120W

24-28V/120W, 3AC400-500V input

24-28V/240W

48-56V/240W

Screw mounting set, two needed per unit

Front view SL2.5

Construction / Mechanics

Housing dimensions and WeightFree space for ventilation

UnitW x H x D [mm]weightleftabove/belowright

•SL2.549 x 124 x 102 460 g0 mm25 mm each10 mm •SL 5.10x64 x 124 x 102 620 g15 mm25 mm each15 mm •SL 5.30073x124 x 117730 g15 mm50 mm each15 mm •SL 10120 x 124 x 102 980 g15 mm25 mm each15 mm Overall depth = depth value as mentioned + DIN rail depth

Robust metal housing with

fine ventilat. grid ( 3,5 mm, IP20), to keep out small parts (e.g. screws) Mounting on DIN-Rail (TS35 /7.5 or TS35/15, 1...1.5 mm thick), thus •Si mple snap-on system •Si ts safely and firmly on the DIN-Rail •No tools required to remove or backplane-mounted (two optional screw mounting sets SLZ01 required)

Side view SL2.5Bottom view SL2.5

Connections

Connections

•In put/Output •Cu rrenthandling capacity •Gr id

Screw terminals, connector size range:

solid 0.5- 6 mm 2 / flexible 0.5- 4 mm 2

30 A per output

Two connectors per output, 9 mm distance

between adjacent connectors

Design

advantages: •A ll connection blocks are easy to reach as mounted at the the front panel. •In put and output are strictly apart from each other and so cannot be mixed up

Your partner in power supply:

European

Power Supply

Manufacturers

Association

PULS GmbH

Arabellastraße 15

D-81925 München

Tel.: +49 89 9278-0

www.puls-power.com

Fax: +49 89 9278-199

Data sheet

2/2 sledrw1/040114

Bayerns Best 50

Czech 100 Best

EuropeÕs 500

his 'mechanics data sheet' exclusively deals with the mechanical properties of the product. For further information (especially concerning electrical properties), please refer to the generic data

sheet of the SL2.5, SL5 and SL10 and to the basic data sheet "The SilverLine" dealing with common features of all SilverLine units. This data sheet is subject to change without prior notice.

Bottom view

SL10SL5.10x

120

Side view and front view

SL10, SL5.10x

All views SL5.300

quotesdbs_dbs22.pdfusesText_28
[PDF] sl6 bac pro

[PDF] co2 polaire ou apolaire

[PDF] molécule apolaire def

[PDF] transcription acte de mariage franco-algérien nantes 2015

[PDF] ccm mariage tunisie

[PDF] formulaire transcription de mariage tunisien

[PDF] formulaire de transcription de mariage franco-marocain

[PDF] mariage sans ccm maroc

[PDF] certificat de capacité de mariage tunisie pdf

[PDF] capacité de mariage franco tunisien

[PDF] transcription mariage marocain sans ccm

[PDF] transcription mariage franco marocain 2016

[PDF] transcription acte de mariage francais au consulat du maroc

[PDF] demande de transcription d'acte de mariage célébré au maroc

[PDF] ccp chimie 2 pc 2014 corrigé