[PDF] ETUDE TECHNIQUE DETAILLEE DUN IMMEUBLE R+3 A USAGE





Previous PDF Next PDF



ETUDE TECHNIQUE DUN BATIMENT R+3 A USAGE DE MARCHE

L'ossature du bâtiment est constituée d'une structure en béton armé porteuse (planchers – poutre – poteaux …) reposant sur un radier nervuré. Les prescriptions 



ETUDE TECHNIQUE DUN BATIMENT R+3 A USAGE DE MARCHE

L'ossature du bâtiment est constituée d'une structure en béton armé porteuse (planchers – poutre – poteaux …) reposant sur un radier nervuré. Les prescriptions 



Cahier des charges type pour la gestion technique des immeubles

des audits sur la qualité des installations des systèmes de Gestion Technique du Bâtiment dans quatre bâtiments à usage de bureaux ou d'enseignement 



ETUDE POUR LA REALISATION DUN IMMEUBLE R+3 A USAGE

Mots clés : Structure Conception



GUIDE DACHAT POUR LA GESTION ECONOME DES FLUIDES

ECONOME DES FLUIDES DANS UN BATIMENT. A QUALITE ENVIRONNEMENTALE. GROUPE D'ETUDE DES MARCHES. AMENAGEMENTS ET EQUIPEMENTS DURABLES DANS LE BATIMENT.



Projet de Construction et déquipement de salles de classe dans les

2 sept. 2017 3?Description sommaire des résultats de l'étude et contenu du Projet ... du marché en petits lots pour la construction des bâtiments permet ...



RAGE - Guide 2014 « Gestion technique du bâtiment »

R ègles de l'Art Grenelle En vironnement 20. 1. 2 ». N. E u. F. -. Ré. NO v. A. TION. GESTION TECHNIQUE DU BATIMENT – BONNES PRATIQUES POUR CONCEVOIR ET 



Organisation dun chantier de bâtiment R+5 avec sous-sol à usage

iii. RESUME. L'organisation d'un chantier de construction du bâtiment La méthode quantitative consistera d'abord à l'étude technique du projet ...



ETUDE TECHNIQUE DUN BÂTIMENT A USAGE COMMERCIAL

ETUDE TECHNIQUE D'UN BÂTIMENT A USAGE COMMERCIAL «RDC+4 » EN. BETON ARME 1-béton armé. 2- étude manuelle. 3- logiciel. 4- assainissement. 5- R+4 ...



ETUDE TECHNIQUE DETAILLEE DUN IMMEUBLE R+3 A USAGE

1 févr. 2018 Le calcul se fait pour la structure entière afin d'avoir les sollicitations du bâtiment à tous les niveaux. La descente de charges étant ...

ETUDE TECHNIQUE DETAILLEE DUN IMMEUBLE R 3 A USAGE

USAGE DE LIBRAIRIE AU

DE OUAGADOUGOU

NVIRONNEMENT

OPTION : BATIMENT

Présenté et soutenu publiquement par : Gaël Kouamé MEH

Travaux dirigés par

Mr. Césaire HEMA

Doctorant au Laboratoire Eco-Matériaux de Construction. 2IE

Mr. Anselme ZOMA

Chef de département ingénierie A.I.C

Mr. Germain ILBOUDO

Ingénieur A.I.C

Jury d'Ġǀaluation du stage

Président : Mr Célestin OVONO MEZUI

Membres et correcteurs :

- Docteur Moussa LO - Mr SORE

Promotion : 2013-2014

i

TABLES DES MATIERES

..iii .v

LISTE ..vi

LISTE DES TA

1

CHAPITRE I EIL ET DU PROJET

I. ..2

II.

CHAPITRE II : ETUDE BETON ARME DE LA STRUCTURE

II. 1 Etude bibliographique

II.2 Méthodologie..5

A.

B- Poutres

C ii D

E- Parois du monte-

F. Fondatio29

F.1- .30

F.2- .34

F.4- .39

CHAPITRE III : ELECTRICITE, SECURITE INCENDIE ET THERMIQUE DU

BATIMENT

I. II. III.

CHAPITRE IV : PLOMBERIE ET DEVIS ESTIMATIF

1. Plomberie

2. Devis estimat

CONCLUSION GENERA

BIBLIOGRAPHIE

iii

REMERCIEMENTS

Je tiens à remercier ma mon grand frère FREDERIC KONAN pour leur soutien pendant cette formation. r accepté de suivre mon travail.

Je remercie PAULE pour ses conseils

opportuns. iv

RESUME

L de type R+3 situé dans

Ouagadougou. Le bâtiment objet de la présente étude à une hauteur totale 15,40m, une longueur de 37,18m et une largeur de 19,07m. e

à la réalisation des travaux. Ainsi nous avons commencé par dimensionner des éléments en

béton armé tel que : les poutres, les poteaux, les parois du monte-charge, le radier partiel, les

nervures et les escaliers. giciel (Robot) Ensuite, nous avons procédé à une étude des réseaux intérieurs sur la plomberie et . Cette étude nous a permis part les différentes sections de câble électrique pour alimenter le circuit électrique, les diamètres de canalisations pour

évacuation des eaux dans le bâtiment.

confort thermique du bâtiment a été fait sur le logiciel " Energy plus » celui-ci nous terne du bâtiment après plusieurs

simulations. Ces simulations ont servi à choisir de différents matériaux isolants du point de vu

thermique. Pour terminer le devis estimatif prévisionnel du projet donne un montant global de sept cent quatre-vingt-quinze million, cinq cent soixante un mille trois cent vingt-huit francs (795 561 328) Francs CFA toutes taxes comprises. Mots clés : Dimensionnement, isolations, R+3, Devis estimatif, Réseaux intérieurs v

ABSTRACT

Project relates to the study technique of one building of type R +3 located in the district 13 of Ouagadougou. The building object of present study with a total height 15,40m, a length of 37,18m and a width of 19,07m. On the basis of architectural plan, we have realized plans of execution necessary

with the realization work. Thus us started by dimensioning elements out of concrete

armed such as: beams, posts, walls of the hoist, the partial foundation raft, veins and staircases. This dimensioning is fact with the software (Robot) Then, we proceeded with one study networks interiors on plumbing and

electricity. This study us allowed to obtain of one leaves the different ones sections

of cable electric to feed the electric circuit, of other leaves the diameters drains for the

food out of drinking water and evacuation water in building. The study on thermal comfort of the building was fact on software "Energy

more " this one has us licence to have the temperature intern and external of the building

afterwards several simulations. These simulations were used for to choose the different ones materials insulators of the point of considering thermics. To finish the estimated estimate project gives a total amount from seven hundred quatre- vingt-quinze million, five hundred and sixty one thousand three hundred and twenty-eight francs (795 561 328) Francs CFA all inclusive of tax. vi

LISTE DES FIGURES

Figure 1

Figure 2 ....9

Figure 3

Figure 4

Figure 5

Figure 6 : ..15

Figure 7

Figure 8 .17

Figure 9

Figure 10

Figure 11

Figure 12 ..24

Figure 13 : 24

Figure 14 : 25

Figure 15

Figure 16

Figure 17

Figure 18 :

Figure 19 : .32

Figure 20 : ......32

Figure 21

Figure 22 :

Figure 23: .......35

Figure 24

Figure 25 : ......36

Figure 26 : ......36

vii

Figure 27 : ..37

Figure 28 ..37

Figure 29 : Contraintes aux cisaillement en x

Figure 30 ......38

Figure 31

Figure 32 .43

Figure 33 : Di

Figure 34

Figure 35

Figure 36 : Travée AB chargées et BC déchargé ELU65

Figure 37 66

Figure 38 66

Figure 39 67

Figure 40 ......67

ix

Figure 41 .........68

Figure 42

Figure 43 .....77

Figure 44 : Moments dues aux charges .....78

Figure 45 ........123

Figure 46 : Plan des é.....124

Figure 47

Figure 48 : Plan de coffrage ét

Figure 49 ......127

Figure 50

Figure 51 ......129

Figure 52 : Eclairage ......131

Figure 53 ......131

.......135 x

LISTE DES TABLEAUX

Tableau 1 :

Tableau 2 : .

Tableau 3 :

Tableau 4

Tableau 5

Tableau 6 : ..........................16

Tableau 7 : Justification aux appuis

Tableau 8 18

Tableau 9 : ..18

Tableau 10 : 19

Tableau 11 ..........................22

Tableau 12 :

Tableau 13 : Formules descente de charge sur 24

Tableau 14 :

Tableau 15 : 26

Tableau 16

Tableau 17 : Calculs des moments e la poutre

Tableau 18 : Aciers de la poutre de libage

Tableau19

Tableau20 : 41

Tableau 21 :

Tableau 22 :

Tableau 23 :

Tableau 24 : 51

Tableau 25 56

Tableau 26 93

Tableau 27 94

Tableau 28 94

xi

Tableau 29: Températures isolation externe-95

Tableau 30 95

Tableau 31 96

Tableau 32 ..97

Tableau 33 122

1

INTRODUCTION GENERALE

La réalisation de tout ouvrage de génie civil ou de bâtiment (immeuble par exemple) suit tout

un processus complexe depuis la phase pour atteindre Le rapport des investigations sur le respect de la réglementation menées en 2009 à

Ouagadougou par la " Brigade spécial

de construire [Ministère de la construction et de lurbanisme burkinabé , 2009] ; des résultats

le domaine de la construction. Dans cette quête de respect des normes de sécurité et de confort,

Ouagadougou a fait appe

détaillée de la construction de son immeuble. nous devons nous poser la question à savoir comment satisfaire aux besoins du ementations.

Ce projet intitulé " étude te » fait

premier temps sur le dimensionnement de la structure et dans un second temps sur les études des résea 1

CHAPITRE I : ET DU PROJET

I-

hitecte Ingénieur Conseil (AIC) est une société à responsabilité limitée qui exerce

dans le domaine du génie civil, son siège social est situé à Ouagadougou.

- Le département architecture est chargé de réaliser les études architecturales des projets ;

- Le département Ingénierie calculs des structures, et le contrôle des travaux.

II- PRESENTATION GENERALE DU PROJET

1. Contexte du projet

ides pouvant assurer son autonomie

3 à usage mixte objet de la présente étude.

2.

Objectif général

aux normes de sécurité (résistance), thétique, et confortable tout en respectant les règles de

Objectifs spécifiques

objectif général :

9 Faire une étude technique détaillée (dimensionnement des ouvrages porteurs, sécurité

incend) du bâtiment pouvant assurer sa stabilité, sa résistance et son confort.

9 Déterminer le cout prévisionnel du projet

Dans cet optique, nous avons procédé à :

- Faire le dimensionnement de la structure porteuse du bâtiment ;quotesdbs_dbs29.pdfusesText_35
[PDF] ETUDE TECHNIQUE D UN BATIMENT R 3 A USAGE DE MARCHE

[PDF] Etude d ingénierie d un bâtiment R 4 ? usage de bureau pour le

[PDF] Dimensionnement beton armé d un immeuble R 5 - BEEP-IRD

[PDF] ÉTUDE D 'UN BÂTIMENT« 2 SOUS SOL, RDC + 9 ÉTAGES » DU

[PDF] ÉTUDE D UN BÂTIMENT« 2 SOUS SOL, RDC 9 ÉTAGES » DU

[PDF] ECE : Notion de précision par l 'étude d 'un ECG - Sciences

[PDF] Conversion DC / DC : hacheurs

[PDF] CCP Physique PC 2016

[PDF] Etude d un cycle frigorifique avec compresseur - Eduscol

[PDF] Étude d 'une pompe ? chaleur - Eduscol

[PDF] Relation Clients et Usagers

[PDF] Dossier Méthodologique Étude de cas Bac Pro Accueil

[PDF] Audit des systèmes d 'information Introduction - cloudfrontnet

[PDF] corrig #7871 - Action éducative

[PDF] Office de Tourisme de Dijon corrigé