[PDF] Modular Type Electro-hydraulic Proportional Flow Control Valve





Previous PDF Next PDF



H - Proportional Electro-Hydraulic Controls

hydraulic proportional pilot relief valve and a low noise type relief valve. proportional electro-hydraulic flow control and relief valves of which model ...



Proportional flow control valve 2-way version

When installing new systems or replacing an amplifier the amplifier settings may have to be adjusted. Page 5. Hydraulics Bosch Rexroth AG. RE 29190/02.07 2FRE.



SERIES Shockless Type Proportional Electro-Hydraulic Directional

adjustment screw completely to the original position. □ Shockless Type Proportional Electro-Hydraulic Directional and Flow Control Valves. These valves are 



Load Response Electro-hydraulic Proportional Relief and Flow

The load sensing function of this meter in flow control valve makes it possible to control pump discharge pressure au- tomatically in accordance with the size.



Proportional Electro-Hydraulic Controls Proportional Electro

Series Proportional Electro-Hydraulic Control Valves. Amplifiers. Valve Type. 24.5 High Response Type Proportional Directional and Flow Control Valves. Note ...



FREP Proportional Priority Flow Control Valve

This material is intended for use in training for. Sun Authorized Sales Channel Partners only. Page 2. 2. © 2021 Sun Hydraulics. FREP Proportional Priority Flow 



40Ω–10Ω Series - Proportional Electro-Hydraulic Flow Control and

The specifications for pressure controls are applied to models with proportional pilot relief valve. (Ex. EFBG-03-125-C-17). The maximum pressure adjustment 



SERIES Proportional Electro-Hydraulic Directional and Flow Control

These valves are double-deck directional and flow control valves employing as their pilot the electro-hydraulic proportional pressure reducing valves with 



Hydraulic Cartridge Systems

Hydraulic Cartridge Systems Division. Threaded Cartridge Valves and. Integrated Hydraulic ... valve body or solenoid coil for your particular application. Also ...



10Ω Series - Proportional Electro-Hydraulic Flow Control (and

Since the preselected flow rate continuously varies in proportion to the current input to the valve the system flow rate can be remote- controlled as 



Modular Type Electro-hydraulic Proportional Flow Control Valve

The pressure fluctuations have little in- fluence on the setting flow rate making this valve perfect for electro-hydraulic proportional control of small 



Proportional Electro-Hydraulic Controls Proportional Electro

Proportional valves are able to control the system pressure or flow proportionally through a controlled input current from the amplifier. Our product line 



40?–10? Series - Proportional Electro-Hydraulic Flow Control and

The specifications for pressure controls are applied to models with proportional pilot relief valve. (Ex. EFBG-03-125-C-17). The maximum pressure adjustment 



Proportional hydraulics (Textbook)

12 Apr 2005 Hydraulic feed unit with electrical control and proportional valves ______ 8. 1.4. Signal flow and components of proportional ...



H - Proportional Electro-Hydraulic Controls

sequence controller or computer. 6. Power amplifier. Details of Proportional Electro-hydraulic Relief Valve. 1. Pressure sensor incorporated.



Electro-hydraulic Proportional Flow Control Valve

This valve controls actuator speed in re- sponse to the size of input current. Pressure and control oil temperature fluctuation has little effect on setting.



Load Response Electro-hydraulic Proportional Relief and Flow

In the case of a safety valve with an electrohydraulic pro- portional pilot relief valve the safety valve setting pressure is set to the minimum adjustment 



YUKEN Hydraulic Equipment

Directional and Flow Control. Valves. Flow Control and Relief Valves a proportional electro-hydraulic control valve and controls the pressure in ...



Proportional flow valves

HYDRAULIC SYMBOLS. 3 way connection. QVHZO-T QVKZOR-T. Proportional flow control valves



YUKEN Hydraulic Equipment

sequence controller or computer. 6. Power amplifier. Details of Proportional Electro-hydraulic Relief Valve. 1. Pressure sensor incorporated.

Electro-hydraulic control valve

MODULAR TYPE ELECTRO-HYDRAULIC

PROPORTIONAL FLOW CONTROL VALVE

Modular Type Electro-hydraulic

Proportional Flow Control Valve

0.3 to 25/min

21MPa

An electro-hydraulic proportional re-

strictor valve and pressure compensa- tion valve are combined into a modular con?guration, available as one of two types: the meter in control EOF-G01-P and meter out control EOF-G01-T.The pressure ?uctuations have little in- ?uence on the setting ?ow rate making this valve perfect for electro-hydraulic proportional control of small hydraulic systems used for machine tool APC and ATC high-speed shockless control, remote control, etc.Handling zAir Bleeding

To enable proper pres-

sure control, loosen the air vent when starting up the pump in order to bleed any air from the pump, and fill the inside of the solenoid with hydraulic operating fluid. The position of the air vent can change by loosening the lock screw and rotating the cover. xManual flow rate adjusting screw

For the initial adjustment or when there is no input current to the valve due to an electrical problem or some other reason, the flow rate can be ad-

justed by rotating the manual adjust- ment screw. Rotate clockwise (right- ward) to increase flow rate.

Normally, this adjusting screw should be returned completely to its original position and secured with the lock nut.

cT Port Back Pressure

Since this valve has an internal drain system, make sure that valve T port back pressure is no greater than 2.5MPa {25.5kgf/cm

2 vUse an operating fluid that conforms to the both of the following. Oil tem- perature: -20 to 70°C Kinematic Vis- cosity: 12 to 400mm2 /s. The recom- mended kinematic viscosity range is

15 to 60mm

2 /s. bO-ring Plate Orientation q The port nearest the nameplate surface is the P port. w The port with a mounting pitch width of 31 (narrow pitch width) is the A port. e The cutout on the O-ring plate is on the A port side.

P T B A

x

EOF-G01-P25

EOF-G01-T25

EOF 01 - P 25 - 11

Note) Value when a Nachi-Fujikoshi special ampli?er is used (with dithering).

Design number

Rated ?ow rate

Control port: P, T

Nominal diameter 01

Mounting method G: Gasket type

Modular type electro-hydraulic proportional ?ow control valve

EOF-G01-P25-11EOF-G01-T25-11Model No.

ItemEOF-G01-P

T 25-11

Maximum Operating PressureMPa{kgf/cm

2 }21{214}

Flow Rate Control Range/min0.3 to 25

Flow Rate Control Port

EOF-G01-P : P port

EOF-G01-T : T Port

T Port Allowable Back PressureMPa{kgf/cm

2 }2.5 {25.5} max.

Hysteresis%3 max. (Note 1)

Response SpeedS0.05

Rated CurrentmA800

Coil Resistance20 (20°C)

Weightkg3.7

Features

Specifications

Explanation of model No.

Installation Dimension Drawings1.440

32.565105

4- 5.5 hole

Nameplate

M4 set screw

(hex Width across ?ats 2)

Manual ?ow rate adjusting screw

Air vent (Air bleeding)

(hex width across ?ats 3) ABT P

3132.546

2140.5

80

1157MAX 110.8

MAX 232.8

M4 set screw

(hex Width across ?ats 2) B P T A

4- 5.5 holeManual ?ow rate

adjusting screw

Nameplate

Air vent (Air bleeding)

(hex width across ?ats 3)

2140.5

80

1157MAX 110.8

MAX 232.8

3132.546

105

1.4 65

32.538.6

Electro-hydraulic control valve

Input Current -

Flow Rate

CharacteristicsPressure -Flow RateCharacteristics

Oil Temperature

Characteristics

EOF-G01-T25

Note) Coil model number

JD64-D2

Seal Part List (Kit Model Number JMS-G01)

Note) The materials and hardness of the O-ring conforms with JIS B2401.

Manual adjustment

section

Part No.Part NamePart NumberQ'ty

16O-ringAS568-012(NBR-90)4

17O-ringNBR-90 P181

18O-ringNBR-90 P94

19O-ringNBR-90 P51

20O-ringNBR-90 P201

21O-ringNBR-90 P201

Performance Curves

Hydraulic Operating Fluid Kinematic Viscosity 32mm 2 /s

Cross-sectional Drawing

Part No.Part Name

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

051015202530

0 200 400 600 800 1000

Input current mA

Flow rate /min

051015202530

0 5 {51} {102} {153} {204}10 15 20

Pressure MPa {kgf/cm

2

Flow rate /min

051015202530

10 20 30 40 50 60

Flow rate /min

Oil temperature C

quotesdbs_dbs14.pdfusesText_20
[PDF] proportional valve rexroth

[PDF] proposal for food delivery service pdf

[PDF] proposition de recherche

[PDF] propulsion system in metro trains

[PDF] pros and cons of blackboard lms

[PDF] pros and cons of free trade

[PDF] protocole expérimental de l'extraction de l'eugénol

[PDF] protocole national de déconfinement

[PDF] prouver que deux droites sont sécantes dans l'espace

[PDF] prove a^n is not regular

[PDF] prove a^nb^nc^n is not regular

[PDF] prove boolean expression truth table

[PDF] prove that a^2^n is not regular

[PDF] prove that the following languages over a b c are not regular

[PDF] provincial court of appeal canada