H - Proportional Electro-Hydraulic Controls
hydraulic proportional pilot relief valve and a low noise type relief valve. proportional electro-hydraulic flow control and relief valves of which model ...
Proportional flow control valve 2-way version
When installing new systems or replacing an amplifier the amplifier settings may have to be adjusted. Page 5. Hydraulics Bosch Rexroth AG. RE 29190/02.07 2FRE.
SERIES Shockless Type Proportional Electro-Hydraulic Directional
adjustment screw completely to the original position. □ Shockless Type Proportional Electro-Hydraulic Directional and Flow Control Valves. These valves are
Load Response Electro-hydraulic Proportional Relief and Flow
The load sensing function of this meter in flow control valve makes it possible to control pump discharge pressure au- tomatically in accordance with the size.
Proportional Electro-Hydraulic Controls Proportional Electro
Series Proportional Electro-Hydraulic Control Valves. Amplifiers. Valve Type. 24.5 High Response Type Proportional Directional and Flow Control Valves. Note ...
FREP Proportional Priority Flow Control Valve
This material is intended for use in training for. Sun Authorized Sales Channel Partners only. Page 2. 2. © 2021 Sun Hydraulics. FREP Proportional Priority Flow
40Ω–10Ω Series - Proportional Electro-Hydraulic Flow Control and
The specifications for pressure controls are applied to models with proportional pilot relief valve. (Ex. EFBG-03-125-C-17). The maximum pressure adjustment
SERIES Proportional Electro-Hydraulic Directional and Flow Control
These valves are double-deck directional and flow control valves employing as their pilot the electro-hydraulic proportional pressure reducing valves with
Hydraulic Cartridge Systems
Hydraulic Cartridge Systems Division. Threaded Cartridge Valves and. Integrated Hydraulic ... valve body or solenoid coil for your particular application. Also ...
10Ω Series - Proportional Electro-Hydraulic Flow Control (and
Since the preselected flow rate continuously varies in proportion to the current input to the valve the system flow rate can be remote- controlled as
Modular Type Electro-hydraulic Proportional Flow Control Valve
The pressure fluctuations have little in- fluence on the setting flow rate making this valve perfect for electro-hydraulic proportional control of small
Proportional Electro-Hydraulic Controls Proportional Electro
Proportional valves are able to control the system pressure or flow proportionally through a controlled input current from the amplifier. Our product line
40?–10? Series - Proportional Electro-Hydraulic Flow Control and
The specifications for pressure controls are applied to models with proportional pilot relief valve. (Ex. EFBG-03-125-C-17). The maximum pressure adjustment
Proportional hydraulics (Textbook)
12 Apr 2005 Hydraulic feed unit with electrical control and proportional valves ______ 8. 1.4. Signal flow and components of proportional ...
H - Proportional Electro-Hydraulic Controls
sequence controller or computer. 6. Power amplifier. Details of Proportional Electro-hydraulic Relief Valve. 1. Pressure sensor incorporated.
Electro-hydraulic Proportional Flow Control Valve
This valve controls actuator speed in re- sponse to the size of input current. Pressure and control oil temperature fluctuation has little effect on setting.
Load Response Electro-hydraulic Proportional Relief and Flow
In the case of a safety valve with an electrohydraulic pro- portional pilot relief valve the safety valve setting pressure is set to the minimum adjustment
YUKEN Hydraulic Equipment
Directional and Flow Control. Valves. Flow Control and Relief Valves a proportional electro-hydraulic control valve and controls the pressure in ...
Proportional flow valves
HYDRAULIC SYMBOLS. 3 way connection. QVHZO-T QVKZOR-T. Proportional flow control valves
YUKEN Hydraulic Equipment
sequence controller or computer. 6. Power amplifier. Details of Proportional Electro-hydraulic Relief Valve. 1. Pressure sensor incorporated.
Electro-hydraulic control valve
MODULAR TYPE ELECTRO-HYDRAULIC
PROPORTIONAL FLOW CONTROL VALVE
Modular Type Electro-hydraulic
Proportional Flow Control Valve
0.3 to 25/min
21MPaAn electro-hydraulic proportional re-
strictor valve and pressure compensa- tion valve are combined into a modular con?guration, available as one of two types: the meter in control EOF-G01-P and meter out control EOF-G01-T.The pressure ?uctuations have little in- ?uence on the setting ?ow rate making this valve perfect for electro-hydraulic proportional control of small hydraulic systems used for machine tool APC and ATC high-speed shockless control, remote control, etc.Handling zAir BleedingTo enable proper pres-
sure control, loosen the air vent when starting up the pump in order to bleed any air from the pump, and fill the inside of the solenoid with hydraulic operating fluid. The position of the air vent can change by loosening the lock screw and rotating the cover. xManual flow rate adjusting screwFor the initial adjustment or when there is no input current to the valve due to an electrical problem or some other reason, the flow rate can be ad-
justed by rotating the manual adjust- ment screw. Rotate clockwise (right- ward) to increase flow rate.Normally, this adjusting screw should be returned completely to its original position and secured with the lock nut.
cT Port Back PressureSince this valve has an internal drain system, make sure that valve T port back pressure is no greater than 2.5MPa {25.5kgf/cm
2 vUse an operating fluid that conforms to the both of the following. Oil tem- perature: -20 to 70°C Kinematic Vis- cosity: 12 to 400mm2 /s. The recom- mended kinematic viscosity range is15 to 60mm
2 /s. bO-ring Plate Orientation q The port nearest the nameplate surface is the P port. w The port with a mounting pitch width of 31 (narrow pitch width) is the A port. e The cutout on the O-ring plate is on the A port side.P T B A
xEOF-G01-P25
EOF-G01-T25
EOF 01 - P 25 - 11
Note) Value when a Nachi-Fujikoshi special ampli?er is used (with dithering).Design number
Rated ?ow rate
Control port: P, T
Nominal diameter 01
Mounting method G: Gasket type
Modular type electro-hydraulic proportional ?ow control valveEOF-G01-P25-11EOF-G01-T25-11Model No.
ItemEOF-G01-P
T 25-11Maximum Operating PressureMPa{kgf/cm
2 }21{214}Flow Rate Control Range/min0.3 to 25
Flow Rate Control Port
EOF-G01-P : P port
EOF-G01-T : T Port
T Port Allowable Back PressureMPa{kgf/cm
2 }2.5 {25.5} max.Hysteresis%3 max. (Note 1)
Response SpeedS0.05
Rated CurrentmA800
Coil Resistance20 (20°C)
Weightkg3.7
Features
Specifications
Explanation of model No.
Installation Dimension Drawings1.440
32.565105
4- 5.5 hole
Nameplate
M4 set screw
(hex Width across ?ats 2)Manual ?ow rate adjusting screw
Air vent (Air bleeding)
(hex width across ?ats 3) ABT P3132.546
2140.5
801157MAX 110.8
MAX 232.8
M4 set screw
(hex Width across ?ats 2) B P T A4- 5.5 holeManual ?ow rate
adjusting screwNameplate
Air vent (Air bleeding)
(hex width across ?ats 3)2140.5
801157MAX 110.8
MAX 232.8
3132.546
1051.4 65
32.538.6
Electro-hydraulic control valve
Input Current -
Flow Rate
CharacteristicsPressure -Flow RateCharacteristics
Oil Temperature
Characteristics
EOF-G01-T25
Note) Coil model number
JD64-D2
Seal Part List (Kit Model Number JMS-G01)
Note) The materials and hardness of the O-ring conforms with JIS B2401.Manual adjustment
sectionPart No.Part NamePart NumberQ'ty
16O-ringAS568-012(NBR-90)4
17O-ringNBR-90 P181
18O-ringNBR-90 P94
19O-ringNBR-90 P51
20O-ringNBR-90 P201
21O-ringNBR-90 P201
Performance Curves
Hydraulic Operating Fluid Kinematic Viscosity 32mm 2 /sCross-sectional Drawing
Part No.Part Name
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21051015202530
0 200 400 600 800 1000
Input current mA
Flow rate /min
051015202530
0 5 {51} {102} {153} {204}10 15 20Pressure MPa {kgf/cm
2Flow rate /min
051015202530
10 20 30 40 50 60
Flow rate /min
Oil temperature C
quotesdbs_dbs14.pdfusesText_20[PDF] proposal for food delivery service pdf
[PDF] proposition de recherche
[PDF] propulsion system in metro trains
[PDF] pros and cons of blackboard lms
[PDF] pros and cons of free trade
[PDF] protocole expérimental de l'extraction de l'eugénol
[PDF] protocole national de déconfinement
[PDF] prouver que deux droites sont sécantes dans l'espace
[PDF] prove a^n is not regular
[PDF] prove a^nb^nc^n is not regular
[PDF] prove boolean expression truth table
[PDF] prove that a^2^n is not regular
[PDF] prove that the following languages over a b c are not regular
[PDF] provincial court of appeal canada