RIPPLE FOLD DRAPERY INSTALLATION INSTRUCTIONS
Installing Your Ripple Fold Drapery: * Note: Drapery track / rail must be installed first (off wall or ceiling) prior to hanging draperies. Please see
RIPPLE FOLD DRaPERy Measure instructions
The finished length you supply us with is the exact measurement the drapery fabric will be made to. •When finalizing ripple fold drapery please remember to
Drapery Track System SPEC (086123)
The Lutron ripple fold drapery system is compatible with Graber snap tape which has a spacing of. 4 1/4 in (108 mm) between snaps. The Buttmaster Carriers and
Calculating and Fabricating a Complex Ripplefold Panel for Traverse
Ripplefold is a type of drapery panel that's creating by sewing a stiff snap tape to the heading of a flat drapery and installing it on track carriers with
Hand Drawn Ripplefold Fabrication Chart
2. Decide whether the drapery treatment will be one or two panels. 3. Determine the fullness of the drapery ripple folds - 120% 100%
Ripple-Fold Drapery Sewing Details
RIPPLE-FOLD DRAPERY SEWING DETAILS. Fabrication. Standard Ripple-Fold draperies are fabricated as follows: Top Hem: 4” wide deluxe hems
Ripple Fold Drapery Installation Instructions
Ripple fold drapery track can be wall mounted or ceiling mounted. Specific brackets are used for each application. The ripple fold track that we provide is pre-
Ripple Fold Drapery Installation Instructions
Once the drapery has been installed most wrinkles and folds will hang out on their own within. 1 – 2 weeks. A garment / commercial steamer may also be used to
Ripple Fold Drapery Installation Instructions
Ripple Fold Drapery. Installation Instructions. Decorative Traverse Rod. Wall Mount Option. Page 2. Wall Mount. Double. Before You Begin. Materials. Please read
MEASURING FOR CUSTOM RIPPLE-FOLD DRAPERY AND
This guide explains how to determine the correct ordering measurements for RH custom Ripple-Fold drapery and corresponding track hardware.
MEASURING FOR CUSTOM RIPPLE-FOLD DRAPERY AND
This guide explains how to determine the correct ordering measurements for RH custom Ripple-Fold drapery and corresponding track hardware.
Hand Drawn Ripplefold Fabrication Chart
2. Decide whether the drapery treatment will be one or two panels. 3. Determine the fullness of the drapery ripple folds - 120% 100%
RIPPLE FOLD DRAPERY INSTALLATION INSTRUCTIONS
Installing Your Ripple Fold Drapery: * Note: Drapery track / rail must be installed first (off wall or ceiling) prior to hanging draperies.
RIPPLE FOLD DRaPERy Measure instructions
RIPPLE FOLD DRaPERy Measure instructions. ORDER In 6 Easy stEPs expert assistance available: theshadestore.com/measure or 800.754.1455.
Ripple Fold Drapery - Brochure
Ripplefold is a trademark name for rolled-pleat drapery construction whereby the pleating in the fabric is achieved through the spacing of the carriers.
Design Studio™ - Wand Control Ripplefold Drapery Hardware
purchasing Hunter Douglas Design Studio™ Wand Control Ripplefold Drapery. Hardware. With proper installation operation and care
Ripple Fold Drapery Installation Instructions
Ripple fold drapery track can be wall mounted or ceiling mounted. Specific brackets are used for each application. The ripple fold track that we provide is pre-
Ripplefold-Fabrication-Guide.pdf
Master carriers that work together to eliminate flat drapery areas giving your drapery panels a full
BRIMAR
Install a Ripplefold Drapery Treatment Sew ripplefold snap tape to backside of panel ... Choose snap carrier based on the drapery.
Ripple Fold Drapery Installation Instructions
Ripple fold drapery track can be wall mounted or ceiling mounted. Specific brackets are used for each application. The ripple fold track that we provide is pre-
48" PANELCOVERAGE
96" PANELCOVERAGE
48" PANELCOVERAGE
1. Measure the window area to determine the necessary rod width.
2. Decide whether the drapery treatment will be one or two panels.
3. Determine the fullness of the drapery ripple folds - 120%, 100%, 80%
or 60%4. Follow the one-way or two-way draw scenario as it applies to your pro
ject. Note: A string of snap carriers cut-to-order cannot be returned or refunded. This also applies to sn ap tape, poles and CS tracks.One-Way Draw
SCENARIO 1: Single Panel 80% Ripplefold Fullness 96" Pole Using the fabrication chart, locate the "80% Fullness" column then scroll down the column looking for a panel coverage of 96". It will b e found under the 93-98 range. Follow that row two columns to the right for the Stack Back Width (22 ¾"). To the right of that is the nu mber of snap carriers required (42). To the far left is the Fabric Width requi red (180"). When ordering, add snap tape, an overlap master carrier and endstop.Two-Way Draw
SCENARIO 2: Double Panel 80% Ripplefold Fullness 96" Pole Using the fabrication chart, locate the "80% Fullness" column then scroll down the column looking for an individual panel coverage of48" (half of the rod width). It will be found under the 46-51 range
Follow that row two columns to the right for the Stack Back Width of EACH panel (14¼"). To the right of that is the number of snap ca rriers required for EACH panel (22). To the far left is the Fabric Width requ ired for EACH panel (95"). When ordering, add snap tape, overlap and underlap master carriers, endstops and stiffeners. Contacting a professional workroom, fabricator and/or installation speci alist is recommended to verify all products needed to complete any Ripplefold sys tem. FOROVERLAP
/uNDERLAP
CARRIERFabric
WidthHemmedPanel CoverageStack
BackWidthno.
ofCarriers120%
Fullness100%
Fullness80%
Fullness60%
Fullness
35 ½10-1411-1613-1714-1988
4414-1818-2017-2219-24910
52 ½18-2120-2422-2724-309 ¾12
6121-2524-2827-3230-3510 ¾14
69 ½25-2928-3232-3635-4011 ½16
7829-3332-3736-4140-4512 ½18
86 ½33-3637-4141-4645-5113 ¼20
9536-4041-4546-5151-5614 ¼22
103 ½40-4445-5051-5556-611524
11244-4850-5455-6061-661626
120 ½48-5154-5860-6566-7216 ¾28
12951-5558-6265-7072-7717 ¾30
137 ½55-5962-6670-7477-8218 ½32
14659-6366-7174-7982-8719 ½34
154 ½63-6671-7579-8487-9320 ¼36
16366-7075-7984-8993-9821 ¼38
171 ½70-7479-8489-9398-1032240
18074-7884-8893-98103-10822 ¾42
188 ½78-8188-9298-103108-11423 ½44
19781-8592-96103-108114-11924 ¼46
205 ½85-8996-101108-112119-1242548
21489-93101-105112-117124-12925 ¾50
222 ½93-96105-109117-122129-13526 ½52
23196-100109-113122-127135-14027 ¼54
239 ½100-104113-118127-131140-14528 ¼56
248104-108118-122131-136145-1502958
256 ½108-111122-126136-141150-1563060
265111-115126-130141-146156-1613162
273 ½115-119130-136146-150161-16631 ¾64
282119-123136-139150-155166-17132 ¾66
290 ½123-126139-143155-160171-17633 ½68
299126-130143-147160-165176-18234 ½70
307 ½130-134147-152165-169182-18735 ¼72
316134-138152-156169-174187-19236 ¼74
324 ½138-141156-160174-1793776
333141-145160-164179-1843878
341 ½145-149164-168184-1883980
350149-153168-173188-19339 ¾82
358 ½153-156173-17740 ¾84
367156-160177-18141 ½86
375 ½160-164181-18642 ½88
384164-168186-19043 ¼90
392 ½168-17144 ¼92
401171-17545 ¼94
409 ½175-1794696
418179-1834798
426 ½183-18648100
435186-19049 ¾102
HAND DRAWN
RIPPLEFOLD FABRICATION CHART
t 847.247.0100brimar@brimarinc.com f 847.247.9270 brimarinc.com48" PANELCOVERAGE
96" PANELCOVERAGE
48" PANELCOVERAGE
1. Measure the window area to determine the necessary rod width.
2. Decide whether the drapery treatment will be one or two panels.
3. Determine the fullness of the drapery ripple folds - 120%, 100%, 80%
or 60%4. Follow the one-way or two-way draw scenario as it applies to your pro
ject. Note: A string of snap carriers cut-to-order cannot be returned or refunded. This also applies to sn ap tape, poles and CS tracks.One-Way Draw
SCENARIO 1: Single Panel 80% Ripplefold Fullness 96" Pole Using the fabrication chart, locate the "80% Fullness" column then scroll down the column looking for a panel coverage of 96". It will b e found under the 93-97 range. Follow that row two columns to the right for the Stack Back Width (20"). To the right of that is the number of snap carriers required (42). To the far left is the Fabric Width requi red (178½"). When ordering, add snap tape, butt master carrier and endstop.Two-Way Draw
SCENARIO 2: Double Panel 80% Ripplefold Fullness 96" Pole Using the fabrication chart, locate the "80% Fullness" column then scroll down the column looking for an individual panel coverage of48" (half of the rod width). It will be found under the 46-49 range
Follow that row two columns to the right for the Stack Back Width of EACH panel (11½"). To the right of that is the number of snap ca rriers required for EACH panel (22). To the far left is the Fabric Width requ ired for EACH panel (93½"). When ordering, add snap tape, butt master carriers, endstops and stiffeners. Contacting a professional workroom, fabricator and/or installation speci alist is recommended to verify all products needed to complete any Ripplefold sys tem. FOR B uTT-MASTER
CARRIER
t 847.247.0100brimar@brimarinc.com f 847.247.9270 brimarinc.comFabric
WidthHemmedPanel CoverageStack
BackWidthno.
ofCarriers120%
Fullness100%
Fullness80%
Fullness60%
Fullness
3413-1313-1413-1616-185 ½8
42 ½14-1615-1917-2119-236 ¼10
5117-2020-2322-2624-287 ¼12
59 ½21-2424-2727-3029-348 14
6825-2828-3131-3535-39916
76 ½29-3132-3636-4040-449 ¾18
8532-3537-4041-4545-4910 ¾20
93 ½36-3941-4446-4950-5511 ½22
10240-4345-4850-5456-6012 ½24
110 ½44-4649-5355-5961-6513 ½26
11947-5054-5760-6466-701428
127 ½51-5458-6165-6871-761530
13655-5862-6569-7377-8115 ¾32
144 ½59-6166-7074-7882-8616 ½34
15362-6571-7479-8387-9117 ½36
161 ½66-6975-7884-8792-9718 ¼38
17070-7379-8288-9298-10219 ¼40
178 ½74-7683-8793-97103-1072042
18777-8088-9198-102108-1122144
195 ½81-8492-95103-106113-1182246
20485-8896-99107-111119-12322 ¾48
212 ½89-91100-104112-116124-12823 ¾50
22192-95105-108117-121129-13324 ½52
229 ½96-99109-112122-125134-13925 ½54
238100-103113-116126-130140-14426 ½56
246 ½104-106117-121131-135145-14927 ½58
255107-110122-125136-140150-15428 ¼60
263 ½111-114126-129141-144155-16029 ¼62
272115-118130-133145-149161-1653064
280 ½119-121134-138150-154166-1703166
289122-125139-142155-159171-1753268
297 ½126-129143-146160-163176-18132 ¾70
306130-133147-150164-168182-18633 ¾72
314 ½134-136151-155169-173187-19134 ½74
323137-140156-159174-178192-19635 ½76
331 ½141-144160-163179-18236 ½78
340145-148164-167183-18737 ¼80
348 ½149-151168-172188-19238 ¼82
357152-155173-176193-1973984
365 ½156-159177-1804086
374160-163181-1844188
382 ½164-166185-18941 ¾90
391167-170190-19342 ¾92
399 ½171-17443 ½94
408175-17844 ½96
416 ½179-18145 ½98
425182-18546 ½100
433½186-18947 ¼102
442190-19348 ¼104
HAND DRAWN
RIPPLEFOLD FABRICATION CHART
quotesdbs_dbs20.pdfusesText_26[PDF] risks of doing business in south korea
[PDF] robert dictionnaire
[PDF] robert service the end of the cold war pdf
[PDF] robot sumo: the official guide pdf
[PDF] robot whispering the unofficial guide to programming fanuc robots pdf
[PDF] robotstudio pack and go
[PDF] rocking microtome
[PDF] rogers long distance rates
[PDF] roissy cdg terminal 4
[PDF] roissy en france nombre d'habitants
[PDF] roland barthes a lover's discourse analysis
[PDF] roland barthes a lover's discourse fragments
[PDF] roland barthes a lover's discourse fragments pdf
[PDF] roland barthes a lover's discourse pdf