[PDF] Ceresit Ceretherm External Wall Insulation Systems





Previous PDF Next PDF



VISAGE Akrilna završna žbuka

CT 60 05 mm fasadna žbuka dio je sustava. Ceresit Ceretherm ETICS te je pogodna za plo?e od ekspandiranog polistirena i mineralne vune. CT 60 0



Ceresit CT 60 0.5 mm

Ceresit CT 60 0.5 mm plaster is used for making building faca- B – s1 d0 in: Ceresit Ceretherm Visage



Ceretherm Systems

101 Ceresit Ceretherm Systems – Product Plaster Ceresit CT 60 VISAGE Acrylic Plaster*



Ceresit Ceretherm External Wall Insulation Systems

Ceresit Ceretherm Visage (Detail Sheet 6) CT 240 (for use with CT 60 CT 63



Ceretherm Systems

101 Ceresit Ceretherm Systems – Product Plaster Ceresit CT 60 VISAGE Acrylic Plaster*



0.5 mm

A Ceresit CT 60 05 mm-es vakolat kiváló választás B-s1



Ceresit CT 60 0.5 mm - VISAGE dekorativni akrilni malter

zgrada uz upotrebu šablona koji imitiraju klinker opeku. CT. 60 0.5 mm kao fasadni malter jedna je od komponenti koja se koristi u Ceresit Ceretherm ETICS-u 



Ceresit Ceretherm External Wall Insulation Systems

Ceresit Ceretherm Visage (Detail Sheet 6) CT 240 (for use with CT 60 CT 63



VISAGE

Tynk Ceresit CT 60 05mm s?u?y do wykonywania elewacji budynków ?onych systemów Ceresit Ceretherm ocieplania ?cian zewn?trznych.



Your perfect insulation system is here

one of the key components of Ceresit Ceretherm Impactum System. Ceresit CT 77 Mosaic Plaster Ceresit CT 60 VISAGE Acrylic Plaster*

Readers are advised to check that this Certificate has not been withdrawn or superseded by a later issue by contacting

NSAI Agrément, NSAI, Santry, Dublin 9 or online at http://www.nsai.ie/modules/certificates/uploads/pdf/IAB090340.pdf

IRISH AGRÉMENT BOARD

CERTIFICATE NO. 09/0340

Henkel Polska Sp. z o.o.,

Domaniewska 41,

02 673 Warszawa, Poland.

T: +48 5656300

F: +48 5656309

W: www.henkel.com, www.ceresit.com CI/SfB 21.9 Rn7 (M2)

Ceresit Ceretherm

External Wall Insulation Systems

Système d'isolation pour murs extérieurs

NSAI Agrément (Irish Agrément Board) is designated by Government to issue European Technical Approvals.

NSAI Agrément Certificates establish proof that the certified products are 'proper materials' suitable for their intended

use under Irish site conditions, and in accordance with the Building Regulations 1997 to 2017 . PRODUCT DESCRIPTION: This Certificate relates to the following Ceresit-

Ceretherm External Wall Insulation Systems:

Ceresit Ceretherm Classic (Detail Sheet 1)

Ceresit Ceretherm Popular (Detail Sheet 2)

Ceresit Ceretherm Premium (Detail Sheet 3)

Ceresit Ceretherm Express (Detail Sheet 4)

Ceresit Ceretherm 60 (Detail Sheet 5)

Ceresit Ceretherm Visage (Detail Sheet 6)

Ceresit Ceretherm Impactum (Detail Sheet 7)

These ETIC systems are each comprised of:

Surface preparation of masonry or concrete

substrate; Full system beads and render-only beads; Insulation board (standard white EPS, carbon- enhanced grey EPS, mineral wool, phenolic);

Cement-based or cement-free undercoat

incorporating an alkali resistant fibreglass mesh;

Organic resin such as acrylic, silicone

decorative finish coat;

Decorative finish;

Mechanical fixings;

Weather-tight joints;

Movement joints;

Provision for limiting cold bridging at external

wall/floor junctions in compliance with

Acceptable Construction Details published by

the DoEHLG; Certificate No. 09/0340 /Ceresit Ceretherm External Wall Insulation Systems

Provision for fire stopping at external

compartment walls and floors.

Henkel Polska is responsible for the design,

manufacture and supply of all components to approved specifications. Henkel Polska has appointed Kilsaran Build as their distribution partners in Ireland.

The system is designed by Henkel Polska and

Kilsaran Build on a project specific basis in

accordance with an approved design process.

The installation of the system is carried out by

installers who have been trained by Henkel Polska or Henkel Polska approved representative, and are approved by Henkel Polska and NSAI Agrément to install the system. Applicators must adhere to strict installation guidelines as specified by Henkel

Polska and Kilsaran Build.

This Certificate certifies compliance with the

requirements of the Building Regulations 1997 to 2017.
USE: This Certificate and Detail Sheets 1 to 4 cover the systems for use as external insulation of: (a) Existing concrete or masonry dwellings; (b) New concrete or masonry commercial or industrial buildings, which are designed in accordance with the Building Regulations

1997 to 2017.

These systems are suitable for use up to a

maximum of six storeys (18m) in height in purpose groups 1(a), 1(c), 2(a), 2(b), 3, 4(a) and 4(b), and for use up to a maximum of five storeys (15m) in height in purpose group 1(b), as defined in TGD to Part B of the Building

Regulations 1997 to 2017.

Detail Sheet 5 covers the system for use as

external insulation on new concrete and masonry residential buildings, and storey height restrictions are stated in that Detail Sheet.

The systems have not been assessed for use with

timber frame or steel frame construction.

In an Irish context, Category I 'Impact

Resistance' includes a wall at ground level readily accessible to the public and vulnerable to hard body impacts but not subjected to abnormally rough use. Category II excludes any wall at ground level adjacent to a public footpath, but includes one with its own private, walled-in garden. Category III does not include any wall at ground level. Table 2 in each Detail Sheet shows the impact resistance classifications achieved by various build-ups of the Ceresit Ceretherm ETIC

Systems.

MANUFACTURE, DESIGN AND MARKETING:

The product is designed and manufactured by:

Henkel Polska Sp. z o.o.,

Domaniewska 41,

02 672 Warszawa,

Poland.

Project specific design, technical support, sales

and applicator approval are performed by:

Kilsaran Build,

Brownstown,

Kilcullen,

Co. Kildare.

W: www.kilsaran.ie/build

Certificate No. 09/0340 /Ceresit Ceretherm External Wall Insulation Systems

1.1 ASSESSMENT

In the opinion of NSAI Agrément, the Ceresit

Ceretherm ETIC Systems, when installed by

Henkel Polska recommended contractors, in

accordance with this Certificate and Kilsaran

Build specific design, can meet the requirements

of the Building Regulations 1997 to 2017, as indicated in Section 1.2 of this Agrément

Certificate.

1.2 BUILDING REGULATIONS 1997 to 2017

REQUIREMENTS:

Part D - Materials and Workmanship

D3 - Proper Materials

The Ceresit Ceretherm ETIC Systems, as certified

in this Certificate, are comprised of 'proper materials' fit for their intended use (see Part 4 of this Certificate).

D1 - Materials & Workmanship

The Ceresit Ceretherm ETIC Systems, as certified

in this Certificate, meet the requirements for workmanship.

Part A - Structure

A1 - Loading

The Ceresit Ceretherm ETIC Systems once

appropriately detailed, designed and constructed have adequate strength and stability to meet the requirements of this Regulation (see Part 3 of this Certificate).

A2 - Ground Movement

The Ceresit Ceretherm ETIC Systems can be

incorporated into structures that meet this requirement (see Parts 3 and 4 of this

Certificate).

Part B - Fire Safety

Part B Vol 2 - Fire Safety

B4 & B9 - External Fire Spread

The Ceresit Ceretherm ETIC Systems can be

incorporated into structures that meet this requirement (see Parts 3 and 4 of this

Certificate).

Part C - Site Preparation and Resistance to

Moisture

C4 - Resistance to Weather and Ground

Moisture

External walls above DPC level have adequate

weather resistance in all exposures to prevent the passage of moisture from the external atmosphere into the building as specified in Part

3 of this Certificate.

Part F - Ventilation

F2 - Condensation in Roofs

The systems as certified can be incorporated into

structures that will meet the requirements of this Regulation (see Parts 3 and 4 of this Certificate).

Part J - Heat Producing Appliances

J3 - Protection of Building

When the Ceresit Ceretherm ETIC Systems are

used in accordance with Section 4.1 of this Certificate, wall lining, insulation and separation distances meet this requirement.

Part L - Conservation of Fuel and Energy

L1 - Conservation of Fuel and Energy

The walls of the Ceresit Ceretherm ETIC Systems

can be readily designed to incorporate the required thickness of insulation to meet the

Elemental Heat Loss method calculations for

walls as recommended in Part L of the Building

Regulations 1997 to 2017 (see Part 4 of this

Certificate).

Part One /

Certification 1

Certificate No. 09/0340 /Ceresit Ceretherm External Wall Insulation Systems

2.1 PRODUCT DESCRIPTION

Each of the Ceresit Ceretherm ETIC Systems is

given a detailed description in the relevant Detail

Sheet.

The substrate on which the Ceresit Ceretherm

ETIC Systems will be used should have a reaction

to fire class A1 or A2-s1 d0 in accordance with

I.S. EN 13501-1.

2.2 MANUFACTURE, SUPPLY AND

INSTALLATION

Henkel Polska is responsible for the design and

manufacture of all components to approved specifications. Henkel Polska has appointed Kilsaran Build as distribution partner in Ireland, with responsibility for:

Project specific design in accordance with

approved design process;

Training, monitoring and review of licensed

applicators in accordance with approved training and assessment procedures;

Product supply and documentation control;

Technical support and installation

supervision;

Sales and marketing.

The installation of the Ceresit Ceretherm ETIC

Systems is carried out by Kilsaran Build trained

and approved installers in accordance with Kilsaran

Build project specific designs and method

statements. Installers must also be approved and registered by NSAI Agrément under the NSAI

Agrément External Thermal Insulating Composite

quotesdbs_dbs24.pdfusesText_30
[PDF] CERESTE "Domaine du Grand Luberon"

[PDF] Céret l`étoile du berger

[PDF] Cerezyme 400 U, poudre pour solution à diluer pour - Santé Et Remise En Forme

[PDF] Cerezyme® : Instructions pour la perfusion à domicile - Chirurgie

[PDF] Cerf élaphe Cerf élaphe - Fédération des Chasseurs de la Nièvre - France

[PDF] Cerf sika.pub - Gestion De Projet

[PDF] Cerf volant modèle n°2 Le chiringa Le chiringa, une - CAN

[PDF] Cerf-Volant - Gestion De Projet

[PDF] cerf-volant - Jeunes.gouv.fr

[PDF] CERF-VOLANT - Le Bureau des Accompagnateurs

[PDF] Cerf-volant chinois Vole dans le vent Vole mon cerf

[PDF] CERF-VOLANT CLUB DE MONTPELLIER

[PDF] cerfa -autorisation de sortie du territoire

[PDF] cerfa 11580*03 - Anciens Et Réunions

[PDF] Cerfa 12156-03 - Compte Bancaire