500001007-K Wessex 50 Install
Due to the high thermal efficiency of the boiler the flue gas temperature is approx. 125oC. Condensation in the flue is thus more likely than with lower.
Review of the Reference Values for High-Efficiency Cogeneration
7 avr. 2015 Data from power plant and boilers installed after 2006 were required. It should be noted that in some cases this was not possible. For example ...
Introduction of High Efficiency Once-through Boiler in Film Factory
The project boiler reduces fuel consumption by higher efficiency and enables the reduction by fuel switch from oil to gas. ? Sites of JCM Model Project.
cast iron high efficiency sectional boiler for gas/oil fuels chaudiere
1.01 Introduction. GE3boiler is a new heating generator with high efficiency for central heating system suitable for burners using oil or gas. The boiler
MA EEAC
The high efficiency of condensing boilers relies on a low boiler return water temperature which means that differences in installation practices that
Triton Series™ High Efficiency Boiler
Triton Series™. High Efficiency Boiler. High Efficiency. Near Condensing Boilers. • 6 models ranging from .8MM to 2MM BTU. • Up to 86% thermal efficiency.
cast iron high efficiency sectional boiler for gas/oil fuels chaudiere
1.01 Introduction. GE3boiler is a new heating generator with high efficiency for central heating system suitable for burners using oil or gas. The boiler
Technip Energies - Low-Emission Cracking Furnace
To reduce the CO? emissions fuel efficiency must be improved. Our research showed that the heat recovery scheme of the conventional furnace configuration was.
HIGH-EFFICIENCY FURNACE INSTALLATION GUIDE FOR
For example the American Society of Heating
[PDF] 2 BOILERS - Bureau of Energy Efficiency
Package boilers are generally of shell type with fire tube design so as to achieve high heat transfer rates by both radiation and convection (Refer Figure 2 4)
High Efficiency and Condensing Boilers - Buderus - PDF Catalogs
Consult Buderus's entire High Efficiency and Condensing Boilers catalogue on ArchiExpo Page: 1/18
[PDF] High Efficiency Boiler Range Technical Guide - Glow-worm
The Glow-worm High Efficiency boilers Technical Guide is designed to assist with the installation and servicing of our latest range of condensing boilers -
[PDF] Efficiency in boilers and beyond - Alfa Laval
Over the years we've refined our main engine solutions creating high-efficiency boilers that remain problem-free in challenging sooty exhaust conditions
(PDF) ENERGY EFFICIENCY ON BOILER - ResearchGate
3 jan 2020 · Abstract ; In oil and coal-fired boilers soot buildup on tubes acts as an insulator ag ; removed on a regular basis Elevated stack temperatures
[PDF] Improving Energy Efficiency of Boiler Systems - PDH Online
The higher the temperature the less energy transferred to output and the lower the boiler efficiency When stack temperature is evaluated it is important to
[PDF] Factsheet Boiler Efficiency - energygovau
A typical condensing boiler has a thermal efficiency of 92-95 in comparison to non-condensing Condensing boilers also have high efficiency burners
[PDF] High Efficiency Gas Fired Heating Boiler - Lochinvar
With Efficiency+ you get high efficiency heating in a surprisingly compact unit It fits easily where other boilers won't The Efficiency+ is remarkably light
[PDF] Improve Your Boilers Combustion Efficiency - govenergyeerewww1
An often-stated rule of thumb is that boiler efficiency can be increased by 1 for each 15 reduction in excess air or 40°F reduction in stack gas temperature
[PDF] High Efficiency Condensing Boiler 1500–3000 MBH - Weil-McLain
High Efficiency Condensing Boiler 1500–3000 MBH Specifications SVF 1500 SVF 1500-3000 Boiler Efficiency Curves Low Water Cut-Off — Manual Reset
What is a high efficient boiler?
A high efficiency boiler is a condensing boiler that provides more heat with less energy use than other systems. The combustion process in these units condense flue gases in a second heat exchanger for extra energy efficiency.How is boiler TPH calculated?
In order to calculate boiler efficiency, we divide the total energy output by total energy input, multiplied by hundred.How many types of boilers are there PDF?
In order of increasing capacity, three boiler types are the fire-tube, water-tube and waterwall boilers. The fire tube boiler, the oldest design, is made so the products of combustion pass through tubes surrounded by water in a shell.- Basically Boiler efficiency can be tested by the following methods: 1) The Direct Method: Where the energy gain of the working fluid (water and steam) is compared with the energy content of the boiler fuel. 2) The Indirect Method: Where the efficiency is the difference between the losses and the energy input.
cast iron high efficiency sectional boiler,for gas/oil fuelschaudiere en fonte haut rendement,pour le chauffage central
INSTALLATION, SERVICE AND USER INSTRUCTIONS
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN cod. 3540Z970 - Rev. 01 - 02/2018 GE3 21. Technical informations ............................................................................................................ 3
2. Dimensions and technical data...............................................................................................3
3. Packing and shipment ............................................................................................................ 5
4. Installation .............................................................................................................................. 6
5. Testing .................................................................................................................................... 7
6. Service.................................................................................................................................... 8
THE MARKING CERTIFIES THAT THE PRODUCTS MEET THE ESSENTIAL REQUIREMENTS OFTHE RELEVANT DIRECTIVES IN FORCE.
THE DECLARATION OF CONFORMITY MAY BE REQUESTED FROM THE MANUFACTURER. cod. 3540Z970 - Rev. 01 - 02/2018 GE3 31. Technical informations
1.01 Introduction
boiler is a new heating generator with high ef ciency, for central heating system suitable for burners using oil or gas. The boiler body is built by cast iron sections joined togheter by mean of biconical nipples and tie rods. Sections ns are especially developed to achieve the best ef ciency of the boiler in order to save on fuel consumption. The boiler body insulation is provided by mineral high density bers that minimizes the body heat lost. Key1 Control thermostat
2 Security thermostat manual resetting
3 Thermometer
213
Fig. 1
1.02 Control and securities devices operation
Regulating thermostat, manual resetting 3 ( g. 1)
It operates when the boiler temperature, during the heating mode reach such a level that can use a danger situation.
Before resetting this thermostat ask for Quali ed Serviceman to inspect the appliance.Control thermostat 1 ( g. 1)
It allows to control the boiler temperature by mean of its knobs.This thermostat controls the burner.
2. Dimensions and technical data
2.01 Flue gas path
English
Français
cod. 3540Z970 - Rev. 01 - 02/2018 GE3 42.02 Dimensions and technical data ( g. 2 - tab. 1)
Fig. 2
Key a1 Flow 1 1/4" a2 Return 1 1/4" a3 Boiler drain 1/2" a4 Flue connection 120-130 mm a5 Burner hole 105 mmTab. 1
ModelHeat and D.H.W.
(net) gas+oilMax.Heat and
D.H.W. output
Max.N°
elementWater capacity dm 3Combustion
chamber lenght mmGE 3 - 2527,8 25,0 3 13 350
GE 3 - 3538,8 35,0 4 17 450
GE 3 - 4549,9 45,0 5 21 550
GE 3 - 5559,6 54,6 25 650
ModelWorking
pressure barABCCombustion chamber load loss p mbarCombustion chamber volume dm 3Water load lossesWeight
of unit kg t 10t 20GE 3 - 256 400 750 380 0,1 20,15 1,8 - 115
GE 3 - 356 400 750 480 0,15 28,21 4,2 1 145
GE 3 - 456 400 750 580 0,15 36,27 7,2 1,6 175
GE 3 - 556 400 750 680 0,2 52,39 11 2,3 205
N.B.: - Max. water temperature for the heating system is 90° C. - Min. water temperature for the heating
system is 45° C.English
Français
cod. 3540Z970 - Rev. 01 - 02/2018 GE3 52.03 Pressure drop ( g. 3)
Pressure drops according to the boiler size are speci ed on the following diagram and refer to temperature diffe-
rence between ow and return comprises between 10 and 20°C.700800900
122030
405060708090200
30040050060010003456789 2010100
10 Q (m 3 /h)Δp (mbar)
Fig. 3
3. Packing and shipment
Boiler is delivered complete assembled in a wood crate.Fig. 4
English
Français
cod. 3540Z970 - Rev. 01 - 02/2018 GE3 6Electrical diagram
KeyTR boiler thermostat
TS Safety thermostat
B Burner
Fig. 5
4. Installation
It is law that all gas appliances are installed by Competent Persons, in accordance with the regulations. Failure to
install appliances correctly lead to prosecution, it is your own interest, and that of safety, to ensure that the law is
coplied with. Manufacturers instructions must NOT be taken in any way as over-riding statutory obligations, special
care must be paid to conform with law and regulation concerning building and location of the chimney.
4.01 Hydraulic connections
Boiler must be connected to the system according to boiler back part indications and those provided at g. 2. Pipe
must be free of any kind of strain and security valves must be provided in both central heating system and domestic
hot water system location of such security valves be as close is possible to the boiler and between the boiler and
valve no obstructions or gate valves must be placed.The boiler is not supplied with expansion tank it has to be provided during the boiler installation. It is advised that
the pressure in the hydraulic system has to be between 0,5 and 1 bar measured in cold water condition.
4.02 Connection to the chim ney
It is recommended to con nect the boiler to a good working chimney built ac cord ing to the regulations. The con-
nection between boiler and chimney must be done by using suitable ma te ri al proof against high tem per a ture and
corrosion. Where ue sections have to be connected it is advised pay at ten tion to avoid leak ing and provided good
in su la tion through all the ue length to avoid condensing problem.English
Français
cod. 3540Z970 - Rev. 01 - 02/2018 GE3 75. Testing
5.01 Before the rst light of the boiler
Before the rst light of the boiler follow these check list: a) check the system is lled with water at the right pressure; b) check against any leakage of water fuel; c) check that the correct electric power is supplied to the unit; d) check size and perfect ue in stal la tion; e) check against any type of am ma ble materials where the boiler is installed; f) check the burner has the right heat input according to the boiler size; g) control that the water valves are open.5.02 First lighting
After the boiler preliminaries check ing , the appliance can be lights in the following way;1) Open the fuel gate valve.
2) Set the regulating thermostat at the required temperature level.
After above operations the burner will start to run and the boiler will begin to work.5.03 After the rst lighting
After the rst lighting it is advisable check:
burner works properly, this check ing must be done by appropriate instruments.Thermostats operate correctly.
Water ows through the system.
Smoke gases evacuate through the ue duct.
5.04 Switch off
To turn off the unit for a short period it is enough to switch off the switch 4 ( g. 1) on the control panel.
If the boiler has to be stopped for long period beside to act by the switch 4, it is necessary to cut the supply of fuel
by mean of the gate valve, in winter season, to avoid damages due to the frost it is necessary to add the antifrost
liquid in the system or to drain it completely.English
Français
cod. 3540Z970 - Rev. 01 - 02/2018 GE3 86. Service
The after sale service must be carried out only Quali ed Plumbers. It is advise to service the boiler at least once
a year, before the winter season. Check must include the boiler cleaning, the perfect operation of the controls and
the burner. Furthermore the ue duct conditions have to be inspected.6.01 Boiler cleaning
Cut out electric power.
The front panels 1, 2, 3 ( g. 6).
Clean the boiler internal parts.
Check the ue duct and if necessary clean it.
The burner service must be done according the Manufacture Instructions. 3 2Fig. 6
English
Français
cod. 3540Z970 - Rev. 01 - 02/20181. Présentation ......................................................................................................................... 10
2. Caractéristiques dimensionelles et techniques .................................................................... 10
3. Conditionnement .................................................................................................................. 12
4. Installation ............................................................................................................................ 13
5. Contrôles .............................................................................................................................. 14
6. Entretien ............................................................................................................................... 15
GE3 9 FR LE MARQUAGE << >> ATTESTE QUE LES PRODUITS SONT CONFORMES AUX EXIGENCES ESSENTIELLES DE L'ENSEMBLE DES DIRECTIVES QUI LEURS SONT APPLICABLES. LA DÉCLARATION CE DE CONFORMITÉ PEUT ÊTRE DEMANDÉE AU FABRICANT. cod. 3540Z970 - Rev. 01 - 02/20181. Présentation
1.01 Introduction
La chaudière GE3 est un nouveau générateur de chaleur à haut rendement, pour le chauffage. Le corps de chauffe est constitué d'éléments en fonte nipples dont le pro l à été particulèrement étudié et qui permet des hautes performances thermiques et par consequence economie d'energie. L'isolation de la chaudière est constitué d'un epais matelas de laine de verre que reduit au minimum la dispersion de la chaleur vers l'exterieur.Legende
1 Aquastat de réglage chaudière
2 Aquastat de sécurité à réarmement manuel
3 Thermomètre
1.02 Fonctions des dispositifs de réglage et sécurité
Aquastat de sécurité à réarmement manuelIl intervient lors que la température chaudière, atteint des valeurs superièurs aux températures reglées sur les
aquastats de fonctionnament. Lors que cet aquastat intervient il y a lieu de contacter votre service après vente.Aquastat de réglage chaudière
Il permet le réglage de la température de la chaudière, cet aquastat commande seulement le brûleur dans la
phase chauffage.Fig. 1
213
2. Caractéristiques dimensionelles et techniques
2.01 Parcours fumées
GE3 10English
Français
cod. 3540Z970 - Rev. 01 - 02/2018N.B.: - La température maxi d'exercice chauffage est de 90° C. - La température mini chauffage est
de 45° C. -./0 -./0 -./10 -./00 2 -./0 -./0 -./10 -./002.02 Données dimensionelles et techniques ( g. 2 - tab. 1)
Legende
a1 Départ installation - 1 1/4" a2 rétour installation - 1 1/4" a3 Vidange chaudière - 1/2"quotesdbs_dbs21.pdfusesText_27[PDF] high net worth individuals survey
[PDF] high paid jobs in demand uk
[PDF] high paying jobs in high demand uk
[PDF] high school admission essay examples about yourself
[PDF] high school computer science textbook pdf
[PDF] high school course codes tdsb
[PDF] high school ela curriculum
[PDF] high school english 12 syllabus
[PDF] high school physics book pdf
[PDF] high school syllabus template pdf
[PDF] high temperature and high humidity reduce the transmission of covid 19 pdf
[PDF] high speed train routes in europe
[PDF] higher education course scheduling
[PDF] higher education in switzerland