[PDF] [PDF] A TABLE OF CONVERSIONS UNITS FOR MAGNETIC PROPERTIES Conversion





Previous PDF Next PDF



Units for Magnetic Properties

Symbol. Quantity. Conversion from Gaussian and cgs emu to SI. ? magnetic flux. 1 Mx ? 10?8 Wb = 10?8 V·s. B magnetic flux density magnetic induction.



UNITS FOR MAGNETIC PROPERTIES Quantity Magnetic flux

Magnetic flux density Magnetic potential difference



Units in magnetism Quantity symbol SI unit cgs unit Length x m = 1

The term emu is short for 'electromagnetic unit' and is not a unit in the conventional sense. It is sometimes used as a magnetic moment (1 emu = 1 erg G?1) and 



Magnetic Unit Systems

chapters the major units and their conversion are given in the table below. Quantity. Symbol. Gaussian unit. Conversion factor. SI unit magnetic induction.



PE005 1.2 Magnetic units of measurement and their conversion

cgs - unit. Conversion. Magnetic flux density. (induction). B. T (Tesla). G (Gauss). Vs m. 1 T. 4. 1. 10. = = 2. G. 10 G. = 1 mT. Magnetic field strength.



Untitled

UNITS FOR MAGNETIC PROPERTIES a. Quantity. Conversion factor Cb. Symbol. Gaussian & cgs emu. C. SI & rationalized mks. Magnetic flux density



A Units in Magnetism

The unit of magnetic field strength H has no special name; H is measured in useful relations for conversion of CGS into the SI are:.



Fundamental Physical Constants and Conversion Factors

By equa- tion (5) one emu/cm3 unit of magnetization will produce a magnetic induction B of 47rJ gauss. The “correct” procedure would be to assign M or J units 



Units for Magnetic Properties

Units for Magnetic Properties. Symbol. Gaussian & cgs emua. Conversion Factor Cb. SI & rationalized mksc. Magnetic flux density



Untitled

Conversion factors for Magnetic Quantities. Symbol. SI Unit. CGS Unit convert to SI J (gauss) and H (Oe) are first converted to M.



[PDF] UNITS FOR MAGNETIC PROPERTIES Quantity Magnetic flux

Magnetic flux density Magnetic field strength Multiply a number in Gaussian units by C to convert it to SI (e g 1 G X10-4 T/G = 10-4 T)



[PDF] PE005 12 Magnetic units of measurement and their conversion

1 Magnetic Units Size Symbols SI - unit not allowed anymore cgs - unit Conversion Magnetic flux density (induction)



[PDF] Units for Magnetic Properties

Symbol Quantity Conversion from Gaussian and cgs emu to SI ? magnetic flux 1 Mx ? 10?8 Wb = 10?8 V·s B magnetic flux density magnetic induction



[PDF] A TABLE OF CONVERSIONS

UNITS FOR MAGNETIC PROPERTIES Conversion Quantity Symbol Gaussian cgs emu a factor C b SI rationalized mks c Magnetic flux density



Magnetic Unit Conversion Chart - Seiko Instruments Inc

SII's DIANET Magnetic Unit Conversion Chart



[PDF] Magnetic Units - IEEE Magnetics Society

UNITS FOR MAGNETIC PROPERTIES Magnetic field strength Multiply a number in Gaussian units by C to convert it to SI (e g 1 GX 10-4 T/G= 10-4 T)



[PDF] Units in magnetism

The term emu is short for 'electromagnetic unit' and is not a unit in the conventional sense It is sometimes used as a magnetic moment (1 emu = 1 erg G?1) and 



[PDF] Conversion table to SI for magnetism related properties - UNLP

Table 2 Conversion table for inch-unit quantities used in magnetic and optical recording Quantity Inch-unit Conversion factor to recommended unit Recommended 



[PDF] TABLE 1 Conversion factors for Magnetic Quantities

Conversion factors for Magnetic Quantities Magnetic Term Symbol SI Unit CGS Unit Conversion Factor Magnetic induction B tesla (T) Magnetic field



[PDF] Units for magnetic properties - GovInfo

Magnetic flux density magnetic induction Magnetic field strength Multiply a number in Gaussian units by C to convert it to SI (e g 1

  • What is the conversion of units for magnetic field?

    By definition, 1 weber per square meter (Wb/m2) = 1 tesla (T). The conversion between gauss and tesla is an easy one: 1 tesla = 10,000 gauss.
  • How do you convert emu G to ka m?

    Most recent answer. To convert emu/g to A/m. Is a two step process. You multiply with the density of the material g/cm^3 to obtain volumetric magnetization emu/cc which 1 emu/cc=1000A/m or 1kA/m.
  • What is the conversion of EMU to cm3?

    The term emu is short for 'electromagnetic unit' and is not a unit in the conventional sense. It is sometimes used as a magnetic moment (1 emu = 1 erg G?1) and sometimes takes the dimensions of volume (1 emu = 1 cm3).
  • Tesla is the SI unit for the magnetic field.

A. TABLE OF CONVERSIONS

UNITS FOR MAGNETIC PROPERTIES

Conversion

Quantity Symbol Gaussian & cgs emu

a factor, C b

SI & rationalized mks

c

Magnetic flux density,Bgauss (G)

d 10 -4 tesla (T), Wb/m 2 magnetic induction

Magnetic fluxffmaxwell (Mx), G

*cm 2 10 -8 weber (Wb), volt second (V*s)

Magnetic potential difference,

U, Fgilbert (Gb) 10/4

pampere (A) magnetomotive force

Magnetic field strength,

Hoersted (Oe),e

Gb/cm 10

3 /4pA/m f magnetizing force (Volume) magnetization g

Memu/cm

3 h 10 3 A/m (Volume) magnetization4 pMG10 3 /4pA/m

Magnetic polarization

intensity of magnetization

J, Iemu/cm

3

4p ´´10

-4

T, Wb/m

2 i 1A*m 2 /kg (Mass) magnetization s , Memu/g 4p ´´10 -7

Wb*m/kg

Magnetic moment

memu, erg/G 10 -3 A*m 2 , joule per tesla (J/T)

Magnetic dipole moment

jemu, erg/G 4 p ´´10 -10 Wb*m i (Volume) susceptibilityc , kdimensionless, emu/cm 3

4pdimensionless

(4 p) 2

´´10

-7henry per meter (H/m), Wb/(A*m) 4 p ´´10 -3 m 3 /kg (Mass) susceptibility c r , k r cm 3 /g, emu/g (4p) 2

´´10

-10 H*m 2 /kg 4 p ´´10 -6 m 3 /mol (Molar) susceptibility cmol , k molcm 3 /mol, emu/mol (4p) 2

´´10

-13 H*m 2 /mol

Permeability

mdimensionless 4p ´´10 -7

H/m, Wb/(A*m)

Relative permeability

j mrnot defined dimensionless (Volume) energy density,

Werg/cm

3 10 -1 J/m 3 energy product k Demagnetization factorD, Ndimensionless l/4pdimensionless

a. Gaussian units and cgs emu are the same for magnetic properties. The defining relation is B =H +4ppM.

b. Multiply a number in Gaussian units by C to convert it to SI (e.g., ´´ 10 -4

T/G = 10

-4 T). c. SI (Système International d"Unités) has been adopted by the National Bureau of Standards. Where two conversion factors are given, the upper one is recognized under, or consistent with, SI and is based on the definition B= m0(H+M), where m0=4pp ´´10 -7

H/m. The lower one is not recognized under SI and is based on the definition B = m0H +J, where the symbol

I is often used in place of J. d.

1 gauss= 105

gamma (gg). e.

Both oersted and gauss are expressed as cm

-1/2 g-1/2 *s -1 in terms of base units. f. A/m was often expressed as "ampere-turn per meter" when used for magnetic field strength. g.

Magnetic moment per unit volume.

h.

The designation "emu" is not a unit.

i. Recognized under SI, even though based on the definition B = m0H +J. See footnote c. j. mr = m / m0 = 1 + c, all in SI. mr is equal to Gaussian m. k. B *H and m0M*H have SI units J/m 3 ; M*H and B*H/4pp have Gaussian units erg/cm 3

R. B. Goldfarb and F. R. Fickett, U.S. Department of Commerce, National Bureau of Standards, Boulder, Colorado 80303, March 1985

NBS Special Publication 696 For sale by the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402

quotesdbs_dbs19.pdfusesText_25
[PDF] magnetic units

[PDF] magnetization curve explanation

[PDF] magnetization formula statistical mechanics

[PDF] magnetization per spin

[PDF] magnetization thermodynamics

[PDF] magnetization units

[PDF] magnitude and phase response

[PDF] magnitude and phase spectrum of fourier series

[PDF] magnitude and phase spectrum of fourier transform matlab

[PDF] magnolia bakery cakes

[PDF] magnolia bakery cupcakes

[PDF] magnolia bakery order online

[PDF] mah aac cet 2019 admit card

[PDF] mah aac cet 2020

[PDF] mah b.ed cet study material