[PDF] [PDF] — The right frequency Shifting power to and from 60 Hz to 50 Hz

Two PCS100 1650kVA static frequency converter (SFC) units were commissioned in October this year, to shift power to and from 60Hz to 50Hz frequencies,



Previous PDF Next PDF





[PDF] Why is 60Hz frequency used in America instead of the 50Hz used in

frequency of the alternating current in household electrical outlets is 50 Hz Many different power frequencies were used in the 19th century throughout the 



[PDF] List of Worldwide AC Voltages & Frequencies - Oaktree Products

13 fév 2016 · Most countries use 50Hz (50 Hertz or 50 cycles per second) as their AC frequency Only a handful use 60Hz The standard in the United States is 120V and 60Hz AC electricity



The origins of 60-Hz as a power frequency - IEEE Xplore

That same year, AEG engineers in Berlin selected 50 Hz as their new power frequency Although much has happened since 1891, these two frequencies remain 



[PDF] 50/60 Hz or 60/50 Hz Frequency converters – CF range - Enag

Standard range: • CFMM – Input supply single phase 50/60 Hz – User output supply single phase 50/60 Hz - Power range : 700 VA to 20 KVA - Input voltage  



[PDF] POWER FOR SHIPS and NAVAL BASES - Power Systems

Frequency converters, “Shore Power” for Ships 50Hz, 60Hz and 400Hz three phase and single phase There is a growing world focus on energy conservation with 



[PDF] List of Voltages & Frequencies (Hz) Around the World

countries that use 60 Hz while the rest typically run on 50 Hz current Single- phase power is primarily for residential use (such as homeowners and what you  



[PDF] 014TB038 Using Switchgear at Frequencies Other Than 60hz

21 avr 1993 · Power Frequency Withstand: Although this rating is best made at rated frequency (20 , so tests at either 50 Hz or 60 Hz can cover both 



[PDF] — The right frequency Shifting power to and from 60 Hz to 50 Hz

Two PCS100 1650kVA static frequency converter (SFC) units were commissioned in October this year, to shift power to and from 60Hz to 50Hz frequencies,



[PDF] VOLTAGE LEVELS & FREQUENCIES VARIATION - PDH Online

Some electrical equipment will operate properly at an electrical frequency of either 50 or 60 Hz Equipment designed for 60 Hz that will not operate properly at 50 

[PDF] power frequency 50hz or 60hz camera

[PDF] power line frequency tolerance

[PDF] power mac g4

[PDF] power mac g5

[PDF] power mac g5 a1047

[PDF] power of adjacency matrix

[PDF] power of board of directors

[PDF] power of ten

[PDF] power spectrum of discrete signal

[PDF] power tool abb knx

[PDF] power word activities

[PDF] power words for education

[PDF] powerful python pdf download

[PDF] powerful sentence starters

[PDF] powerpoint 14th amendment equal protection

Because all the world is not at the same

frequency, ABB PCS100 SFC technology has been developed to bridge the gap in todays industry environments where equipment has different voltages and frequencies. It provides the economical solution for converting power to and from 60Hz and 50Hz frequencies.

Oil and gas operations are mostly situated in

merciless locations, from the intense forces of the arctic to the sweltering heat of deserts and hazardous conditions on the exposed open seas.

To sustain and secure operating environments in

these remote areas, reliable and stable power is crucial. ABB's PCS100 technology has recently been installed to improve the performance of the remote global offshore oil and gas industry operations based in the Congo. Two PCS100 1650kVA static frequency converter (SFC) units were commissioned in October this year, to shift power to and from 60Hz to 50Hz frequencies, linking LPG floating storage and offloading vessel

N'KOSSA II with its connecting production

platform. This multi-billion dollar industry is heavily reliant on maintaining continuous and efficient operations of its drilling equipment, pumping systems, and refrigeration functions at the production site. Equipment must be sufficiently robust to withstand extreme conditions; flexible to support multiple services; and be cost effective to lower capital expenditures and operating costs.ABB's power converter product range represents a quantum leap in high power technology, particularly in relation to it's technical performance and economic operation. The PCS100 SFC is a proven, efficient and effective power system that is specifically designed to interconnect incompatible networks. The PCS100 SFCunits installed replaced former technology to give a highly reliable system that is a more flexible, efficient, and cost competitive approach to supplying the frequency and voltage neccessary. This particular

ARTICLE

The right frequencyShifting power to and from

60 Hz to 50 Hz

01 LPG floating storage

and offloading vessel

N'KOSSA II

02 Installing and

commissioning the

PCS100 SFC system on

the N'Kossa II offloading vessel 01 application has been designed to supply power from the platform to the vessel, avoiding operation of its onboard diesel generators.

Key features and flexibility

ŮAbility to parallel with multiple generators

ŮHigh system availability throughadvanced

power module redundancy

ŮCapacity to provide output immunity toinput

disturbances (for voltage sags and frequency shifts)

Ů-The unity power factor rectifier with a

ŮTHDi of <3% provides lower harmonics

ŮAligned to inflexible space constraints

ŮMinimal operating and maintenance costs

ŮProtects sensitive and expensive loads

ŮClean sinewave output voltage

Typical applications

Ů50 to 60Hz or 60 to 50Hz industrial applications

ŮDockside converter - allows generators to be

turned off while at port to save fuel and elimi- nate pollution

ŮReplacement of motor generator sets

ŮAs a clean power supply to isolate an unstable grid from a critical load

To find out more about ABB's power protection

solutions:

Web: www.abb.com/ups

Email: powerconditioning@abb.com

ABB LTD.

Power Protection NZ

111 Main North Road

4110 Napier,

New Zealand

abb.com/ups

Additional information

We reserve the right to make technical

changes or modify the contents of this document without prior notice. With re- gard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatso- ever for potential errors or possible lack of information in this document.

We reserve all rights in this document

and in the subject matter and illustra- tions contained therein. Any reproduc- tion, disclosure to third parties or utili- zation of its contents - in whole or in parts - is forbidden without prior writ- ten consent of ABB AG. Copyright© 2018

ABB All rights reserved

2UCD401246-P_a

02quotesdbs_dbs19.pdfusesText_25