[PDF] [PDF] 117 Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

EX7 EX8 Electrical Control Valves Series EX4, EX5, EX6, EX7 EX8 from the Internet at www emersonclimate eu, or use the quick bis +80°C EX6 EX8 



Previous PDF Next PDF





[PDF] Universal Driver Module EXD-U02 for Electrical Control Valves EX4

Emerson Climate Technologies GmbH EXD-U02 Universal Driver Module is for driving Emerson stepper motor driven electrical control valves series EX4-8 and CV4-7 Typical application Closing time (sec ) EX4-6 2 5 CV4-6 2 5 EX7 4 5 CV7 13 15 EX8 6 8 und drücken Sie sie nach unten und hinten, bis



[PDF] Electrical Control Valves EX4-8 - Emerson Climate Technologies

control of refrigerant mass flow in refrigeration, air conditioning, heat pumps EX4 EX5 EX6 EX7 EX8 Maximum working pressure PS 90 bar (uni-flow), 60 bar (bi-flow) zudrehen – eindrücken – weiter andrehen, etc bis Stecker festsitzt



[PDF] EC3-332 Coldroom Controller - Emerson Climate Technologies

control and a driver for an Alco Controls Electrical Control Valve EX4 EX8 In addition the EC3-332 controls air temperature and manages defrost and fan(s) Anschlußdrähte/-kabel müssen für Betrieb bis 90°C zugelassen sein (EN 60730- 1) 



[PDF] EXD-SH1/2 Controller with ModBus communication capability for

EXD-SH1/2 are stand-alone superheat and or temperature controllers EXD-SH1 is intended (1uu + 1u9) / (2uu +2u9) EX4/5/6 ≤ 5 3 Seconds EX7 ≤ 5 6 Seconds EX8 Temperature control function is possible only with EX4-8 series valves If other Erst nach dessen Beseitigung erscheint der nächste Alarm usw bis



[PDF] 117 Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

EX7 EX8 Electrical Control Valves Series EX4, EX5, EX6, EX7 EX8 from the Internet at www emersonclimate eu, or use the quick bis +80°C EX6 EX8 



[PDF] Alco Controls

tool can be downloaded from www emersonclimate eu, or use Electrical Control Valves Series EX4, EX5, EX6, EX7, EX8 ture range TS -40°C bis +80° C



[PDF] EC3-X32 Superheat Controller with TCP/IP communication capability

Emerson Climate Technologies GmbH www emersonclimate eu ut Installed valve type 1 12 5 1 = EX4 2 = EX5 3 = EX6 4 = EX7 5 = EX8 6 = FX5 7 = FX6



[PDF] EC3-X33 Superheat Controller and ECD-002 Keypad / Display Unit

Emerson Climate Technologies GmbH www emersonclimate eu ut Installed valve type 1 12 5 1 = EX4 2 = EX5 3 = EX6 4 = EX7 5 = EX8 6 = FX5 7 = FX6



[PDF] General Product Guide 2012 - ALFACO

Emerson Climate Technologies - European Headquarters - Pascalstrasse 65 - 52076 Aachen, Germany Tel +49 (0) 2408 Bus to system controller: RS 485, 3 -wire, (+,-,GND) for the EX4 to EX8 range of electrically driven control valves



pdf Operating instructions Electrical Control Valves EX4-8

Las EX4-8 son válvulas de motor paso a paso que aseguran En aplicaciones de válvula de expansión y inyección de - a la máxima presión de trabajo del sistema en el el control preciso del flujo refrigerante en sistemas de líquido: resto de aplicaciones refrigeración aire acondicionado bombas de calor y - La válvula debe ser instalada tal y como



EX4-EX8 Electrical Control Valve EX Valves & Controls - Emerson

• Full travel time: EX4-EX6: 1 5 seconds EX7: 3 2 seconds EX8: 5 2 seconds The EX4-EX8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems Multifunction capability as expansion valve hot gas bypass suction gas throttlinghead pressure liquid line actuator and other



Images

Phase current operating EX4/EX5/EX6: 500mA max-10 EX7: 750mA ±10 EX8: 800mA ±10 Holding current EX4/EX5/EX6: 100mA EX7: 250mA EX8: 500mA Nominal input power per phase EX4/EX5/EX6: 3 5W EX7/EX8: 5W Dimensions (mm) Valve Type B C D E H1 EX4-I21 8 45 55 11 113 EX4-M21 8 45 55 11 113 EX4-U31 11 55 55 11 113



Electrical Control Valves EX4/EX5/EX6/EX7/EX8 - Copeland

EX4/5/6/7/8 are stepper motor driven valves for precise control of refrigerant mass flow in refrigeration air conditioning heat pumps industrial cooling process and close control systems as: Expansion valves Liquid injection for subcooling and desuperheating Capacity control: hot gas bypass regulator Capacity control: suction pressure regulator

[PDF] EXA Français admission 2015

[PDF] EXA PRO CONCOURS CONDITIONS ET EPREUVES PERMIS DE

[PDF] exáàtâÜtÇà Ät `tÜÖâ|áx wx _|áÄx

[PDF] EXACOMPTA PL Verkauf - Anciens Et Réunions

[PDF] ExaControl 7 - Saunier Duval - Électricité

[PDF] Exacontrol E7 - Saunier Duval - Électricité

[PDF] Exacontrol7 radio

[PDF] Exact Côte d`Azur - Gestion De Projet

[PDF] EXACT MOVE T-SHIRT SANS MANCHES

[PDF] EXACTA ARMOIRES DE SECURITE - Anciens Et Réunions

[PDF] exacta serie efo - France

[PDF] EXADERM - Anciens Et Réunions

[PDF] exagan

[PDF] Exage 2500 FD - Rapala France - France

[PDF] exagon-Erhebung: Anforderungsmanagement bei den IT