[PDF] [PDF] F02/EPI2 Quarter-Turn Electric Actuator - Biffi Actuators

Rotary switch SW4 Rotary switch SW6 Figure 2 Model 250-500-1000-2000 all configuration operations must be carried out by specifically qualified personnel for operations on powered electronic damage to the electrical components



Previous PDF Next PDF





[PDF] Manual: Electric Actuators model EPI-2 IOM, Keystone - Emerson

Warning The electronic parts of the EPI-2 and all the 2 KEYSTONE Keystone ePi-2 quarter-turn electric actuator INSTALLATION AND MAINTENANCE INSTRUCTIONS B Product model for electrical connections use components



[PDF] Keystone EPI2 - Emerson

The EPI2 is an intelligent quarter-turn electric actuator designed for direct mounting to a Components - Model 2000 / E171 Part Electronic Remote Controls



[PDF] Keystone Electric Actuators, Model EPI-2

Keystone OM3 - EPI-2 LOcaL IntErfacE MOduLE INSTALLATION AND WarnIng EPI-2 actuator must be electrically isolated before WarnIng The electronic parts of the EPI-2 actuators or reconstruction of the above components are



[PDF] F02/EPI2 Quarter-Turn Electric Actuator - Biffi Actuators

Rotary switch SW4 Rotary switch SW6 Figure 2 Model 250-500-1000-2000 all configuration operations must be carried out by specifically qualified personnel for operations on powered electronic damage to the electrical components



[PDF] KEYSTONE EPI-2 ELECTRIC ACTUATORS - Applied Control

2 KEYSTONE EPI-2 ELECTRIC ACTUATORS COMPONENT PARTS - MODELS 063/E006-125/E013-250/E025-500/E051-1000/E091 Part Description



[PDF] Industrial Valve Manual - Elkhart Brass

The Keystone EPI2 electric actuators covered in this manual are designed to Integral controls unit inclusive of electric motor, motor controls, electronic Check that the information on the nameplate (Model, Serial Number, Nominal Torque, Nominal Voltage For all electrical connections, use components (cable glands,



[PDF] EPI2-MAN-652 - Regional District of Central Okanagan

14 sept 2017 · The electronic parts of the actuator can be damaged by a discharge of static The Keystone EPI² electric actuators covered in this Instruction and The EPI2 is an electric quarter-turn actuator suitable to operate a valve or damper 2 2 Check that the information on the nameplate (Model, Serial Number, 



[PDF] Seimens feb_05qxd

Keystone 2- and 3-Way Resilient Seated Butterfly Valve Assemblies Copyright 60 psi; Electronic (w/and w/o Keystone Figure 777 Electric Actuator - (E2, EM and EP Assemblies) Model Electric Manual Lbs Lb -in Range (Lbs ) EPI-3 3500:1 70:1 15 240 0-10Vdc and 4-20mA Modulating Actuator Components



[PDF] 2- & 3-Way Resilient Seat Butterfly Valve Assemblies 2- & 3-Way

Electronic (w/and w/o spring return): 0-10 V, 4-20 mA, Keystone Figure 222 and Figure AR2 Resilient Seat Butterfly Valves EPI 2 Electric Actuator Easily accessed control panel allows setting of torque, speed, and position All metal gearing (on most models) 0-10Vdc and 4-20mA Modulating Actuator Components

[PDF] Keystone Exam Fact Sheet - Pittsburgh Public Schools

[PDF] Keystone Knife Gates, Figure 952

[PDF] Keystone Module RJ45 female > LSA Cat.6

[PDF] Keystone TFoundry - Klingspor Museum

[PDF] Keystones Appartement à louer € 1.190 - Anciens Et Réunions

[PDF] Keystones Appartement à louer € 1.400

[PDF] Keystones Maison à vendre € 535.000

[PDF] keyTec AZ - Winkhaus

[PDF] keyTec RAP

[PDF] Keytis 2-RTS Keytis 4-RTS Ref:1840044, 1840034 - France

[PDF] Keytrade Bank : bénéfice net de € 1,568,000 au troisième trimestre

[PDF] Keytrade Bank Carte VISA Gold Assistance voyage - France

[PDF] Keytrade Bank dans le giron du Crédit Agricole

[PDF] Keytrade Bank enrichit sa gamme de produits bancaires en ligne

[PDF] Keytrade Bank est à Genève !

F02/EPI2 Quarter-Turn

Electric Actuator

Base and OM1 Card

F02/EPI2 Base and OM1 Card

April 2018

Quick Start Guide

VCIOM-08536-EN Rev. 0Base Card

F02/EPI2 Quarter-Turn Electric Actuator

Figure 1

Model 063-125

Green LED

Power ONDip switch

SW3Push button

SW5

Red LED

Enter configuration

Rotary switch

SW4Rotary switch

SW6

Figure 2

Model 250-500-1000-2000

Dip switch

SW3

Green LED

Power ON

Rotary switch

SW6Rotary switch

SW4Red LED

Enter configurationPush button

SW5

Table 1.Operating Times

Model

Nominal torque

(Nm/lb.in.)

Operating time (secs 90

o ) at selected step 864

06363/600152848

125125/1300152848

250250/2500152848

500500/5100152848

10001000/9100244580

20002000/1770053100180

Note: (*) Factory

PRE-INSTALLATION: See VCIOM-2881 INSTALLATION AND MAINTENANCE INSTRUCTIONS. Not performing the following procedures will invalidate the product warranty.

INSTALLATION: To assemble the actuator onto the valve proceed as follows: a. Verify proper mounting hardware. b. Verify proper electrical service to the actuator c.

d. e. Install the actuator onto the valve so that the shaft out put drive enters the groove of the stem extension. This coupling must take place without forcing and only with the weight of the actuator.

f. Ensure actuator and valve are in same orientation when bolting together. g. With the handwheel, operate the actuator to verify it moves the valve smoothly.

WARNING

cards. Hazardous voltages may be present. Before connecting power to the actuator, check that the voltages are correct and according to the nameplate data. Improper power supply will cause permanent

Quick Start Guide

VCIOM-08536-EN Rev. 0

F02/EPI2 Base and OM1 Card

April 2018

See table 1Rotary Switch Settings

Configurations

Move switch SW4 to position

indicated in each row

Move switch SW6 to position

indicated in each row SW3 SW5

Red LED

SW3

CLOSE LIMIT by position21 (*)

PUSH

LED lights up once

Drive the actuator to

the CLOSE position using the handwheel 00

OPEN LIMIT by position31 (*)LED lights up once

Drive the actuator to

the OPEN position using the handwheel 10

CLOSE LIMIT by torque20 (*)

Operate the

actuator to direction bylocal/remote control and wait until it stops by

OPEN LIMIT by torque30 (*)

CLOSING speed44

6 (*) 8

LED lights up once

OPENING speed5

% CLOSING torque62 = 50%

5 = 75%

9 = 100% (*)% OPENING torque7

CW/CCW8

0 = CW (*)

1 = CCW

BLINKER/local selector4

0 = off (*)

1 = Blinker

2 = Loc. Sel.

Quick Start Guide

VCIOM-08536-EN Rev. 0

F02/EPI2 Base and OM1 Card

April 2018

OM1 Card

F02/EPI2 Quarter-Turn Electric Actuator

Figure 3

Input Signal Configuration

SW5Confirmation Push Button

SW2Rotary Switch

SW8 SW7 SW9

Enter

Configuration

Red LED

Input Signal Configuration

SW3

Enable Configuration Mode

SW4

SW6 SW1

Output Signal Configuration

Hardware Configuration

Input Signal

SW3SW5

121

0-10VONOFFOFF

4-20mAOFFONON

Output Signal

SW1SW6

12341

0-10VOFFONONOFFON

4-20mAONOFFOFFONOFF

Rotary Switch Settings

Configurations

Move switch SW8 to

position indicated in each row

Move switch SW7 to

position indicated in each row

Move switch SW9 to

position indicated in each row SW4 by SW2

Red LED

SW4

RELAYS LS3-LS570=break

1=make (*)

Any position

SW4 to ON Push

LED lights up once

SW4 to 1 (Run Setting)

RELAYS LS4-LS68

POSITION Relays LS300 to 9 [0=(*)]

POSITION Relays LS410 to 9 [3=(*)]

POSITION Relays LS520 to 9 [7=(*)]

POSITION Relays LS630 to 9 [9=(*)]

SET Input as "4-20mA"9

0=off

1=on (*)

4

SET 0% input 4-20mA

4

0 = 4mA (*)

Any position

SET 100% input 4-20mA1 = 20mA (*)

SET Input as "0-10V"

9

0=off (*)

1=on 5

Feedback mA or Vdc

2= mA (*)

3= Volt

1

Modulation

0=off (*)

1=on 3

See table 2

Table 2.

SW7Position Relays0123456789

WARNING

For complete Instruction & Warning see the VCIOM-01494 INSTALLATION AND MAINTENANCE INSTRUCTIONS. HARDWARE

OFF (NO power supply).SW3 and SW5 position in order to set the INPUT signal type. Note: (*) Factory default data

PRE-INSTALLATION: See the BASE CARD procedure.

INSTALLATION: See the BASE CARD procedures.

World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers.

Choose the WACC or sales office nearest you:

www.emerson.com

©2018 Emerson. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co. The contents of this publication are presented for information purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, without notice. For complete list of sales and manufacturing sites, please visit Or contact us at info.actuation technologies@emerson.com

NORTH & SOUTH AMERICA

19200 Northwest Freeway

Houston TX 77065

USA

T +1 281 477 4100

Av. Hollingsworth

325 Iporanga Sorocaba

SP 18087-105

Brazil

T +55 15 3413 8888

ASIA PACIFIC

No. 9 Gul Road

#01-02 Singapore 629361

T +65 6777 8211

8VRJOH%FWFMPQNFOU"SFB

Tianjin 301700

P. R. China

T +86 22 8212 3300

MIDDLE EAST & AFRICA

P. O. Box 17033

Jebel Ali Free Zone

Dubai

T +971 4 811 8100

P. O. Box 10305

Jubail 31961

Saudi Arabia

T +966 3 340 8650

24 Angus Crescent

Longmeadow Business Estate East

P.O. Box 6908 Greenstone

1616 Modderfontein Extension 5

South Africa

T +27 11 451 3700

EUROPE

Holland Fasor 6

Székesfehérvár 8000

Hungary

T +36 22 53 09 50

Strada Biffi 165

Italy

T +39 0523 944 411

quotesdbs_dbs14.pdfusesText_20