battery backup power and surge protection (see figure B), taking care not to exceed use a similar cable between the UPS and the device, as indicated in figure C alimentazione del computer per un UPS con prese IEC (vedere figura A)
Previous PDF | Next PDF |
[PDF] Virtual Machine Backup Guide - VMware
Virtual Machine Backup Guide methods you can use to perform backup and restore tasks or snapshots for the individual virtual machines (one per disk) than Windows NT 4 0, Windows 2000, Windows XP, Windows XP Professional, or
[PDF] NetWorker Performance Optimization Planning Guide
20 mai 2019 · Limit memory usage on the host during clone operations 86 Chapter 3 Chapter 4 Network latency on 10/100 MB per second Large Density FS Backup - WAN between NetWorker Clients and Server (High Packet Loss) document, contact a technical support professional Note
[PDF] Backup Solution Guide - Download Center - Synology
detailed information about each feature, please check the Synology official website Backup ・ Uni- Use the 3-2-1 Backup Strategy to protect your family photos, videos and corporate data, thereby minimizing the risk folder, 1 per LUN
[PDF] Eaton Ellipse PRO UPS 650/800/1200/1600 VA Installation and user
battery backup power and surge protection (see figure B), taking care not to exceed use a similar cable between the UPS and the device, as indicated in figure C alimentazione del computer per un UPS con prese IEC (vedere figura A)
[PDF] Eaton Ellipse ECO UPS - 500/650/800/1200/1600 - Installation and
Voltage/frequency of battery backup outlets 9 in battery checked by a professional or use another wall l Accensione dell'UPS: premere per 1 secondo il
[PDF] Manage Media with Final Cut Pro Libraries - Apple
Final Cut Pro uses a production-focused library format for media You can view and set storage locations for each of your libraries you can use tools in Final Cut Pro to automatically back up all of your subject to change without notice
[PDF] Empower System Administrators Guide - Waters Corporation
3 8 Backing Up and Restoring Server Disk Images Empower Toolkit Professional Help: Describes how to use the Each tablespace has one or more rows
[PDF] Publication 1586 - Internal Revenue Service
IRC 6721, Failure to File Correct Information Returns, imposes a penalty per return for each of the following infractions (in a backup withholding notice ( CP2100/ In addition, IRC 6721(f) and IRC 6722(f) pro- matches the name/ TIN combination on SSA or IRS files, use the following information when filing information
pdf Mise en route Nero BackItUp - Notice Facile
1 1 Nero BackItUp Nero BackItUp est un programme simple d'utilisation pratique et puissant permettant de sauvegarder et de restaurer des données Les données sensibles et les données importantes doivent être stockées sur plusieurs supports de sorte qu'ils soient toujours disponibles si nécessaire
[PDF] Version nouvelle! BullGuard. Backup
[PDF] MISSION D ACCOMPAGNEMENT DE L AGENCE DE DEVELOPPEMENT TOURISTIQUE DU LOIR-ET-CHER POUR LE LANCEMENT DU PROJET DE DEPLOIEMENT D UNE PLACE DE MARCHE
[PDF] Console de gestion Online Backup 3.8 Manuel d utilisation
[PDF] Inauguration du Pôle Basso Cambo Mercredi 5 juin 2013
[PDF] «Saint-Brieuc Gare» Les acteurs du territoire de Saint-Brieuc présentent le projet urbain du quartier de la Gare aux opérateurs immobiliers
[PDF] EN PARTENARIAT AVEC VOUS PROPOSE L EXTERNALISATION DES SAUVEGARDES DE VOS DONNEES DE GESTION PACK MODO ET PACK COMPTA
[PDF] SÉNAT PROPOSITION DE LOI
[PDF] Réunion d information sur l électromobilité. et le déploiement de bornes de. de recharge publiques
[PDF] TYPES DE PLAIES PARTICULARITES 24/01/2014 PRISE EN CHARGE DES PLAIES EN SOINS PALLIATIFS EN FIN DE VIE EN FIN DE VIE ESCARRES (1) ESCARRES (2)
[PDF] Livret d accueil des personnels en contrats aidés
[PDF] Actualité de l Immobilier
[PDF] Site Internet CPO. Mode d'emploi
[PDF] Equipe Spécialisée Alzheimer ESA
[PDF] Mise en garde à l égard des énoncés prospectifs
Installation and
user manualEnglish - Français
Deutsch - Italiano
Español - Nederlands
Português -
- SlovenijaSvenska - Suomi
Ellipse PRO
650/850/1200/1600
www.eaton.comCE compliance contact: Eaton I.F. SAS - 110 rue Blaise Pascal - 38330 Montbonnot St Martin - France
3Quick start
5 InOutInternet Modem / Network
MasterEcoControl
B C A1200 / 1600650 / 850FR / DINIEC
D 4 the device. a b c d e c b e f a d650 / 850
1200 / 1600
Caution. Battery service life is reduced by 50 % for every ten degrees above 25 °C.Eaton to ensure correct operation of the
UPSThe battery must be disposed of in accordance with applicable regulation�s. To remove the battery, shut down the
UPS (button6 OFF), remove the power cord and proceed as indicated below "Battery change".
5Output cables should not exceed 10 m length.
Ellipse PRO65085012001600
UPS power650 VA /
400 W850 VA /
510 W1200 VA /
750 W1600 VA /
1000 W
165 V - 264 V, adjustable to 150 V - 284 V
Input frequency50/60 Hz (46 - 70 Hz working range)Voltage/frequency of battery backup
outlets19 in battery mode220 V / 230 V / 240 V +15 % -20 % (50/60 Hz ± 1 Hz)
Total output current for all outlets10 A max
Output current of battery backup
outlets 193 A max3.6 A max5.5 A max7.3 A max
Leakage current0.4 mA
Input protection10 A resettable circuit breaker
Transfer time5 ms typical
Telephone/Data surge protection
Sealed lead-acid battery12 V, 7 Ah12 V, 9 Ah2x12V, 7 Ah2x12V, 9 AhAutomatic battery testOnce a week
Average battery life4 years typical, depending on temperature and number of discharge cyclesOperating temperature0 to 35 °C
Storage temperature-25 °C to +55 °C
Operating relative humidity0 to 85 %
Operating elevation0 to 2000 m
Electromagnetic compatibility standardsIEC 62040-2, C1*Warranty3 years
Dimensions (mm/inch)260 x 82 x 285 / 10.24 x 3.23 x 11.22275 x 82 x 390 / 10.83 x 3.23 x 15.35 Weigth (kg/lb)6.9 / 15.27.3 / 16.19.7 / 21.411.5 / 25.465085012001600
Uoc (common mode / differential mode)6 kV / 2 kV
Up (common mode / differential mode)1.8 kV / 1 kV
In3 kA
Dielectric isolation
AC Ground1500 Vac, 50 Hz
AC / TEL3000 Vac, 50 Hz
Tel / Ground1000 Vac, 50 Hz
Uc250 Vac
Ut430 Vac
405 Joules
6ENGLISH
1. Operating conditions
This product is an Uninterruptible Power Supply (UPS) for computers and their peripherals, television sets, stereo systems and video recorders... It must not be used to supply other electrical equipment (lighting, heating, household appl�iances, etc.). UPS can be installed in horizontal, vertical position, or placed in Rack 2U (optional kit).2. Description
AVR Mi n Hz kV AkW 6 7 8 6 battery backup outlets7Scroll down
8ASR LED
LCD 16 15 14 17 1110912
13 9
10AVR mode
11Battery mode
12Internal fault
13Output load level
Battery level
15Input measurements
16Output measurements
17Measuring unit
Outlets
InOut Inte rnet Modem / NetworkMasterEcoControl
1200 / 160
0650 / 850
18 19 20 19 18 2018Surge protection outlets
19Battery backup outlets
20Protection (circuit breaker)
7ENGLISH
3. UPS connections
Connect the UPS 1 to the AC-power system via a wall outlet with an earth connector, using the supplied cord your computer for a UPS with IEC sockets Plug critical equipment (computer, monitor, modem, etc.) into the outlets19 providing
the rated current indicated in amperes. Other devices (printer, scanner, fax, etc.) can be connect to the surge protection outlets the event of a power outage. A modem or Ethernet data line can be protected against surges by connect�ing it via the UPS. Connect the existing device cable between the wall outlet and the UPS, and supplied). The UPS device can be connected to the computer using the USB cable5 supplied
Eaton UPS Companion software is downloadable from powerquality.eaton.com. Register for the warranty on powerquality.eaton.com. the Ellipse PRO is equipped withEcoControl
outlets that are dependent on the Master outlet. When the main device supplied by the Master outlet (computer) is shut �down, theEcoControl
outlets are automatically deactivated and the peripherals shut down. tool integrated in the software. when the function is activated, do not connect critical applications toEcoControl
outlets. A default setup ensures the correct operation of theEcoControl
function. However, depending on the consumption of the main load, the trigger threshold of �theEcoControl
First, make sure that the function is activated in the "EcoControl Function" tab of the If the peripherals connected to the EcoControl outlets do not switch off when the main value must be set to High If the rated consumption level of the main load is low and the EcoControl outlets shut down when the main load is operating normally, the detection threshold v�alue must be set to Low. 8ENGLISH
6. Operation
The UPS charges the battery as soon as it is connected to the AC outlet, whether button maximum performance after it has been charged for 8 hours. It is recommended that the UPS be permanently connected to the AC power supply to ensure the best possible performance.Switching-on the UPS
Press button
6 for about 1 second.
Surge protection outlets
18 Equipment connected to these outlets is supplied as soon as the AC cord is plugged in. They are not affected by button 6. 19 Equipment connected to these outlets is supplied as soon as button6 turns green
These outlets can be turned on even if the UPS is not connected to AC power (button5. UPS setting through the LCD
l LCD shut off if no activity for 3 minutes.5s2s2s2s2s
(165 - 264 V)Output voltageInput voltage toleranceEcoControlAlarm (150 - 284 V)Save the new value
10s5s5s
9ENGLISH
(For further information, visit the www.powerquality.eaton.com site or contact after-sales support.)DiagnosticSolution
1• The battery backup outlets
19 are not supplied with power.• Button 6 is not lighted on.• Press button 6 and check that it turns green.2• The connected devices are not
supplied when AC power fails.• The devices are not connected to the battery backup outlets19.• Connect the devices to the
battery backup outlets 19.3• AC power is available, but the
UPS operates on battery power.• Circuit breaker20, located at
the rear of the UPS, has been tripped by an overload on theUPS output.• Disconnect excess equipment
and reset the circuit breaker 20 by pressing the corresponding button. 4Green button
audible alarm beeps every 3 seconds.• The UPS battery backup outlets19 are overloaded.• Disconnect excess equipment
connected to the battery backup outlets 19 . 5Fault sign
12 appear on the LCD panel and audible alarm beeps continuously.• A fault has occurred on the UPS.The battery backup outlets
19 are
no longer supplied.• Call after-sales support. 6Green LED
8 is off and the
18 are supplied.• Surge protection is no longer
provided.• Call after-sales support.7• EcoControl outlets keep powered
when main application (Master outlet) is stopped.• EcoControl function is not activated or not properly set.• Activate or set properlyEcoControl function using the
software provided with the product. If AC power is disturbed or fails, the UPS continues to operate on battery p�ower.Button
then every three seconds when the end of battery backup time is near. In silent mode, the audible alarm simply beeps once when the UPS transfers to battery power. If the power outage lasts longer than the battery backup time, the UPS s�huts down and automatically restarts when power is restored. Following a complete discharge, a few hours are required to recharge the battery back to full backup time.All outlets include surge protection.
19Press button
6 for more than two seconds.
10FRANÇAIS
1. Conditions d'utilisation
Cet appareil est une Alimentation Sans Interruption (ASI) conçue pour alimenter un ordinateur et ses périphériques, des appareils de TV, HI-FI, Vidéo, à l'exclusion de tout autre appareil électrique (éclairage, chauffage, électromén�ager...).
L'ASI peut être installée en position horizontale, verticale, ou en Rack 2U (kit optionnel).2. Description
AVR Mi n Hz kV AkW 6 7 8 6Bouton MARCHE/ARRÊT
pour les prises secourues par batteries8Voyant ASR
LCD 16 15 14 17 1110912
13
9ASI en fonctionnement
10Mode AVR
11Mode batterie
12Défaut interne
1315Mesures en entrée
16Mesures en sortie
17Unité de mesure
Prises
InOut Inte rnet Modem / NetworkMasterEcoControl
1200 / 160
0650 / 850
18 19 20 19 18 20 18Prises protégées contre les
surtensions.19Prises secourues par batterie
20Protection (disjoncteur)
11FRANÇAIS
3. Raccordement de l'ASI
Raccorder l' ASI 1 au réseau électrique sur une prise murale avec terre, à l'aide du cordon fourni pour une ASI votre ordinateur pour une Connecter les prises des appareils critiques (ordinateur, écran, modem...) sur les prises secourues par batterie ne dépassant pas le courant indiqué en Ampères. Les autres appareils (imprimante, scanner, fax...) peuvent être branchés sur les prises protégées contre les surtensions secourues en cas de coupure de courant. Pour une meilleure ventilation, laisser un minimum d'espace autour de l'A�SI. La ligne modem ou réseau Ethernet peut être protégée contre �les surtensions en la raccordant via l' ASI. Pour celà, relier d'une part la prise murale à l'ASI avec le cordon de l'appareil à protéger, et d'autre part l' ASI à cet appareil à l'aide d'un cordon identique, L'appareil ASI peut être connecté à l'ordinateur via le câble USBLe logiciel Eaton UPS Companion peut être téléchargé à par�tir du site powerquality.
eaton.com. Enregistrement de la garantie sur le site powerquality.eaton.com. lorsque la fonction est activée, ne pas connecter d'applications critiques sur les prisesEcoControl.
Paramétrage des seuils
Un paramétrage par défaut garantit le bon fonctionnement de la fon�ctionEcoControl
Cependant, selon le niveau de consommation de la charge principale, il p�eut êtreEcoControl
à l'aide du
s'assurer tout d'abord que la fonction soit bien activée dans le� volet "FonctionEcoControl
si les périphériques connectés sur les prises EcoControl ne s'arrêtent pas quand la veille), il est nécessaire d'augmenter la valeur du seuil de dé�tection au niveau Haut si le niveau de consommation nominal de la charge principale est faible �et que les prisesEcoControl
s'arrêtent alors que la charge principale fonctionne normalement, il est nécessaire d'abaisser la valeur du seuil de détection au ni�veau Bas 12FRANÇAIS
6. Utilisation