13 mai 2019 · Adjustabe Half Hanger HFR-HAJ-A is designed to support the fascia overhang formwork on projects where welding is not permitted The hanger
Previous PDF | Next PDF |
[PDF] C24 TYPE 1PR-INT Precast Half Hangers - Product Data - BuildSite
DESCRIPTION Our C24 Pres-Steel Half Hanger are interior form Hangers that consist of a U shape end clip welded to a shaped wire strut APPLICATION
[PDF] C110C & C110S WELDING HALF HANGERS - Dayton Superior
Hangers are available with standard 45°, 90° and 15° tube sections that are welded to a 3/8" thick steel plate APPLICATION C110 Half Hanger made for use with
[PDF] Bridge Deck Handbook - BUILDING STRENGTH™
Half Hanger Strut Wire Fillet Weld h h 1∕2" Minimum Note: For additional details on welding Pres-Steel Hangers to Rebar stirrups, contact Dayton Superior
[PDF] Interior Hangers - Muller Construction Supply
On occasion, there is a need for an interior half hanger that may be welded to the top C24 Type S Pres-Steel Steel Beam Half Hangers are produced using a
[PDF] BRIDGE DECK FORMING & HANGING SYSTEMS - National
13 mai 2019 · Adjustabe Half Hanger HFR-HAJ-A is designed to support the fascia overhang formwork on projects where welding is not permitted The hanger
[PDF] Concrete Bridge Forming C-60 Pres-Steel Hangers - Construction
hanger be used to support overhang brackets only C-25 Adjustable Half Hangers D-1-LA Note: Hanger is fabricated 1/2” wider than flange width specified
[PDF] INSTALLATION INFORMATION - Zambelli
Dimensions for Half-Round Gutters Determination of Stretch plumb line between the two fascia hangers (A+C) and align the other fascia hangers (B) on the
[PDF] Bridge Deck Forming System - SureBuilt
Half hangers must be positioned so the end clip will bear on the top surface of the precast concrete beam • Type 1-PR Precast Half Hanger – 90° end clip (when
[PDF] Berger Building Products Catalog
K-Style Hangers Half Round Hangers Shanks Half Round Gutter Guard ROOF DRAINAGE: Berger Gutters Downspouts Elbows Offsets Hangers Shanks
[PDF] half log dilution
[PDF] half mast flag protocol
[PDF] half octave frequency
[PDF] halo effect advantages and disadvantages
[PDF] halo effect experiment
[PDF] halo effect research paper
[PDF] halogenoalkane reactions
[PDF] halogenoalkanes a level chemistry
[PDF] haloperidol
[PDF] halt tm
[PDF] halting problem proof
[PDF] halting problem reduction
[PDF] halton till
[PDF] ham cooking temperature chart
Concrete
Forming Systems
Precast Concrete
Products
Reinforcing
Bar Supports
Concrete
Anchoring Systems
Rock Anchoring
and Bolt Systems BRIDGE DECKFORMING & HANGINGSYSTEMSINTERIOR HANGERSEXTERIOR HANGERSBRACKETSWORKING PARTS
2TABLE OFCONTENTS
Table of Contents
DIAGRAMS
Steel Girder..............................................................4 Concrete Girder........................................................6 Fascia Overhang......................................................8EXTERIOR FORM
Heavy Ty-Back 90°- 45° Angle Hanger.....................10 Type #1 - 90°- 45° Angle Hanger..............................10 Heavy Ty-Back Inverted 90°- 45°............................11 Type #2 & #3 - 90° - 45° Haunch Angle Hanger.........1145° Precast Angle Hanger......................................12
HK 45° Ty-Down Hanger........................................12 Type #1 - 45° Half Hanger.....................................13 Type #1 - 45° Adjustable Half Hanger.....................136M Adjustable Half Hanger...................................14
Heavy 6M - 15° - 45° Hanger...................................15 Type #1 - 15° - 45° Angle Hanger..............................15 Guardrail Base........................................................16 Guardrail Adapter...................................................16 BOB Wall Plate.......................................................16 Standard Fascia Overhang Bracket.........................17 Adjustable Fascia Overhang Bracket......................18Typical Adjustable Fascia Overhang Bracket Application...18Deep Adjustable Fascia Overhang Bracket..............19
Typical Deep Adjustable Fascia Overhang Bracket Application....19 ARB-89-L Overhang Bracket...................................20 AR Bridge Overhang Bracket Junior.......................20 AR Fascia Bridge Overhang Bracket Extension.......21 HFOB - STD - Overhang Bracket and Exterior Hanger Spacing...22 HFOB - ADJ - Overhang Bracket and Exterior Hanger Spacing...25 HFOB - ADJ - Deep Overhang Bracket & Ext. Hanger Spacing...29INTERIOR FORM
Heavy Ty-Back 90°-90° Hanger..............................34 Type #1 - 90° - 90° Hanger.....................................34 Type #2/Type #3 - 90°-90° Haunch Hanger................3590° Precast Half Hanger.........................................35
90° Ty-Down Hanger..............................................36
Type #1, #2, #3 - 90° Half Hanger.........................37 Type #1 - 90° Adjustable Half Hanger....................38 Type #1 - 15° Adjustable Half Hanger....................3815°-15° Hanger.....................................................39
Batter Washer........................................................3915° Precast Half Hanger.........................................40
Tyloop Hanger........................................................412286mm (90") LENGTH
762mm (30") MINIMUM TO 1727mm (68") MAXIMUM
INTERIOR
90/901/2" HFR1/2" HFR
1/2" HTBH
3/4" HHTBH
3/4" HDHTBH
3/4" HDDHTBH
1/2" HFR-HK
1/2" HTBH-HK
1/2" HFR-H
1/2" HFR-HW
1/2" HTBH-H
1/2" HTBH-HW 1/2" HFR-HA
1/2" HFR-HWA
1/2" HTBH-HA
1/2" HTBH-HWA
1/2" HFR-HAJ 1 CLIP
1/2" HRR-HAF 2 CLIP1/2" HFR-HAJ-A 1 CLIP
1/2" HRR-HAJ-A 2 CLIP
1/2" PHFR-H
1/2" PHHFR-H1/2" PHFR-HA
1/2" PHHFR-HA3/4" HHTBH-HK
3/4" HDHTBH-HK
3/4" HDDHTBH-HK 1/2" HFR-HKA
1/2" HTBH-HKA
3/4" HHTBH-HKA
3/4" HDHTBH-HKA
3/4" HDDHTBH-HKA 1/2" HFR #2
1/2" HFR #3
X 1000 lbs.X 1000 lbs.
1/2" HRH-A #2
1/2" HRH-A #3
1/2" HTBH-A
3/4" HHTBH-A
3/4" HDHTBH-A
HOOK 90HALF 90ADJUSTABLE 90PRECAST
90/45HOOK 45HALF 45ADJUSTABLE 45PRECAST
EXTERIOR
0 810 12 14 16 18
0 2 4 6 2
4 6 810 12 14 16 18
TSAFE WORKING LOAD @ Approximate 2:1 Safety Factor
SAFE WORKING LOAD
@ Approximate 2:1 Safety Factor 3.833 A AA 3.833 AAA12 B 610B B18 B B 610
B6 4.5 F F 6 4.5 FF3 E 1.1 3 E1.1C
3.8610
1218CCCC C
3.8610
12 CCC6 6 D 3.8 3.8 DDD 66D 3.8 3.8 DDD18 B18 C
TABLE OFCONTENTS
Table of Contents
Adjustable Joist Hanger............................................42 "J" Bolt................................................................... ..44 Lagstud Bolt.............................................................4 4 Adjustable Lagstud Bolt............................................44 Continuous Threaded Lagstud...................................45 Flat Washer..............................................................46 Lagnut & Coil Nut.....................................................47 Handle Lagnut..........................................................47 47Hi-Chair Support - Type A300 Void Loop Hold Down Unit...48 AR Adjustable Screed Supports.................................48 Interior / Exterior Hangers Table.................................49 4
Bridge Cross SectionSteel Girder
APPLICATIONDIAGRAMAPPLICATIONDIAGRAM
Guard Rail
2x4 Nailer
Extension
HFOB Fascia Bracket
Lagstud BoltJoistBulkhead
Fascia Hanger
Pg. 10Pg. 10Pg. 11Pg. 11Pg. 12Pg. 12Pg. 13Pg. 13Pg. 15Pg. 15Pg. 44
Pg. 44
Pg. 17Pg. 21Pg. 21
Lagstud Bolt
Guard Rail
2x4 Nailer
Extension
HFOB Fascia Bracket
Lagstud BoltLagstud BoltLedgerBulkhead
Fascia Hanger
Pg. 44Pg. 44Pg. 17
APPLICATIONDIAGRAM
APPLICATION
DIAGRAM
6Bridge Cross SectionConcrete Girder
APPLICATIONDIAGRAMAPPLICATIONDIAGRAM
HFOB Fascia Bracket
Lagstud BoltInterior Hanger
Fascia Hanger
Pg. 44Pg. 17
HFOB Fascia Bracket
Lagstud BoltFascia Hanger
Pg. 44Pg. 17
APPLICATIONDIAGRAM
APPLICATION
DIAGRAM
Pg. 10Pg. 10Pg. 11Pg. 11Pg. 12Pg. 12Pg. 13Pg. 13
Pg. 34Pg. 15Pg. 15
Pg. 35
8Fascia Overhang
APPLICATIONDIAGRAM
Walkway
Safety Rail
Exterior
Formwork
Precast
Concrete
GirderAdjustable Fascia
Overhang Bracket
Lagstud Bolt,
Flat Washer
and LagnutLagstud Bolt,Flat Washer
and LagnutInteriorFormworkLagnut
90º-45º Hanger
EXTERIOR FORM
APPLICATIONDIAGRAM
Pg. 10
Pg. 44
Pg. 44Pg. 18
10EXTERIOR HANGERS
Heavy Ty-Back 90°- 45° Angle Hanger (HTBH-A)TYPE #1 - 90°- 45° Angle Hanger (HFR-A)
EXTERIOR HANGERS
Safe Working Load
17.0 kN (3,800 lb)Safe Working Load
6M 1/2" HTBH-A 26.7 kN (6,000 lb)
10M 3/4" HTBH-A 45.0 kN (10,000 lb)
12M 3/4" HTBH-A 53.0 kN (12,000 lb)
18M 3/4" EHTBH Double 80.0 kN (18,000 lb)
All Supplemental Hangers Rated 4.5kN (1000 lb)
Per side @ Approximate 2:1 Safety Factor
Per side @ Approximate 2:1 Safety Factor
Heavy Ty-Back (HTBH-A) hangers are used to support exterior formwork on bridge decks. HTBH-A hangers are specially designed to react lateral forces prevalent in fascia overhang formwork.The HTBH-A hanger is fabricated to use 13mm or20mm (2`212`2" or 4b434b4") fasteners which is based on load capacity.
Typically 45º end clips are welded to one end of the hanger and90º ty-back end clip to the other end. For improved stability of
the overhang formwork, a 90º SUPPLEMENTAL HANGER which allows a 13mm (2`212`2") vertical tie (SWL1000 lb) to be added to th e main hanger next to the 45º end clip on request. Angle Hanger HFR-A is manufactured with a 13mm (2`212`2") dia.45° end clip and 13mm (2`212`2") dia. 90° end clip welded at eac
h end of the wire strut and is used to support fascia overhang formwork.90°- 45° Heavy Ty-Back
Hanger HTBH-A
NCA Type 1-AP
Hanger HTBH-AP
90°- 45° - 90° Supplemental
Ty-Back Hanger HTBH-AS
Double Hanger EHTBH
INFORMATION REQUIRED TO ORDER
SPECIFYQUANTITYGIRDER FLANGE WIDTHPRODUCT NAMECOATINGExample200350 (14")HTBH-AHDG
Example200350 (14")HTBH-ASHDG
Example200350 (14")3/4"HTBH-AHDG
INFORMATION REQUIRED TO ORDER
SPECIFYQUANTITYGIRDER FLANGE WIDTHPRODUCT NAMECOATINGExample200350 (14")HFR-AHDG
*Available in Plain Steel (B), Electro Plated (EP) and Hot Dip Galvanized (HDG) Consult with AR Technical Department for Hanger Length Less than 175mm (7") NB. When hangers are used on concrete beams, the safe working load shown is based on a minimum concrete ange thickness of 5" and beams made with normal weight concrete having reached a minimum compressive strength of 5,000 psi. For hangers used on concrete beams with conditions not meeting these requirements please contact AR Technical Department. AR recommends the use of bearing plates under hanger end clips for hanger loads greater than 26kN (6000 lb) when used on concrete girders or supports. Please consult with AR Technical Department for custom made hangers with loads other than that listed in this calalog.*Available in Plain Steel (B), Electro Plated (EP) and Hot Dip Galvanized (HDG)WARNING: Lateral forces must be properly reacted in order to prevent hanger movemen
t. Heavy Ty-Back Inverted 90°- 45° (Inv 90-HTBH-A) Type #2 & #3 - 90° - 45° Haunch Angle Hanger (HRH-A) - 25mm (1") / (HRH-A) - 38mm (1-1/2") This hanger is useful for projects where bridge brackets for formwork is to be installed for forming the bridge cantilever overhang only. These hangers can be used on steel or concrete girders where adequate reaction can be provided by a 4b434b4" diameter high strength stud. Bearing plates are recommended for concrete girders with flange thicknesses less lhan 5" and also for hanger > 6000 lb capacity. Hanger > 204mm length is also available with 90" supplement. Haunch Angle Hanger HRH-A is used to form fascia overhangs on projects having a 1" (25mm) or 38mm (1-1/2") haunch condition. The hanger is fabricated with a 13mm (1/2") dia.90° HRH-A end clip and a 13mm (1/2") dia. 45° HFR end clip.
Haunch relief heights: Type #2 HRH-A is 25 mm (1").Type #3 HRH-A is 38 mm (1-1/2").
Safe Working Load
13.4 kN (3,000 lb)
Per side @ Approximate 2:1 Safety Factor
INFORMATION REQUIRED TO ORDER
HANGER TYPESAFE WORKING LOADMINIMUM LENGTH45º BOLT DIMENSIONFOR USE ON6M inv90-HTBH-A26 kN (6,000) lb15 2mm (6")13 mm (½")STEEL / CONCRETE
10M inv90-HTBH-A44 kN (10,000) lb204 mm (8")19 mm (¾")STEEL / CONCRETE
12M inv90-HTBH-A53 kN (12,000) lb204 mm (8")19 mm (¾")STEEL GIRDERS
INFORMATION REQUIRED TO ORDER
SPECIFYQUANTITYGIRDER FLANGE WIDTHPRODUCT NAMETYPECOATINGExample200350 (14")HRH-A#3HDG
Note: The safe working load
(SWL) shown here are based on hanger tests where the hanger has been adequately restrained by a ¾" high strength stud.The actual safe working load of
the hanger is totally dependent on the size and strength of the stud that will be used to provide the hanger reaction at the inverted 90 degree end.As such the hanger installed
capacity may be less if it is not adequately restrained.Please consult with AR technical
department for guidance on useof this product. Please consult with AR technical department for details on AR high capacity 18,000 lb SWL Hangers
*Available in Plain Steel (B), Electro Plated (EP) and Hot Dip Galvanized (HDG) WARNING: Lateral forces must be properly reacted in order to prevent hanger movemen t.THREADED STEEL STUD
HEX NUT
AR INVERTED 90º ENDAR 45º END
EXTERIORHANGERS
EXTERIOR
HANGERS
90°- 45° Heavy Ty-Back
Hanger HTBH-AP
12EXTERIOR HANGERSEXTERIOR HANGERS
45° Precast Angle Hanger (PHFR-HA) & (PHHFR-HA)
HK 45° Ty-Down Hanger (HHFR-HKA)Precast Angle Half Hanger PHFR-HA/PHHFR-HA is designed to be cast into the top of a concrete girder and subsequently support the fascia overhang formwork. Available with a 13 mm (1/2") dia. 45° end clip Standard (PHFR-HA) and Heavy (PHHFR-HA) configurations. Heavy Hanger HHFR-HKA is manufactured with a 13 mm (1/2") diameter 45° end clip welded to one end of the hanger's strut. This hanger is also available in 20 mm ( 3/4") system fabricated with ends to accommodate 20 mm (3/4") rods, for higher loads. The other end of the strut has a reinforced, 180° wraparound configuration. The wraparound end is fabricated to slip over the flange of a steel bridge beam. Also available for hanger loads using 20 mm (3/4") ends.INFORMATION REQUIRED TO ORDER
SPECIFYQUANTITYPRODUCT NAMECOATING
Example200PHFR-HA STDHDG
INFORMATION REQUIRED TO ORDER
SPECIFYQUANTITYGIRDER FLANGE
WIDITHGIRDER FLANGE
THICKNESSPRODUCT
NAMECOATING
Example200350 mm (14")25 mm (1")HHFR-HKAHDG
Example200350 mm (14")32 mm (1 1/4")3/4" HHFR-HKAPHDG Available in Plain Steel (B), Electro Plated (EP) and Hot Dip Galvanized (HDG)NB. Precast Hangers can be Made to Custom Lengths Upon Request.*Embedment height measured from bottom of horizontal strut wire
to bottom of hook wire, as illustrated on the image above. WARNING: Hook hanger are designed and fabricated to slip around the girder ange. They use of force / hammering to t hanger to the girder ange is not permitted and may compromise the integrity of the hanger. If force is required to t the hanger clips to the girder ange then the hanger clips are incorrect and should be replaced. *Available in Plain Steel (B), Electro Plated (EP) and Hot Dip Galvanized (HDG)