house is how many BTUs/hr the One Ton of Heating load (12,000 Btus/hr ) Boise Idaho It's easy and the answer does not matter as much as you might think
Previous PDF | Next PDF |
[PDF] SIZING HVAC EQUIPMENT - Energy Trust Insider
house is how many BTUs/hr the One Ton of Heating load (12,000 Btus/hr ) Boise Idaho It's easy and the answer does not matter as much as you might think
[PDF] A/C Cooling Load calculation and measurement - Testo
how much heating or cooling is taking place This is especially A refrigeration ton is approximately equivalent to 12,000 BTU/h or 3 5 kW/h Air- conditioning
[PDF] How to Convert HVAC Tons to Amps How to Calculate BTU Hours to
For a list of specific heat capacities, see the first link in "Resources " If, for instance, you are heating copper, which has a heat capacity of 0 386: 9 x 0 386 = 3 474 3
[PDF] Fuel Value Calculator - Forest Products Laboratory - USDA Forest
from any type of fuel that contains water, including wood, coal, and 0 073 ton $120/ton $882 aBased on 100 million Btu of energy for the heating season
[PDF] Why 400 CFM per Ton is used for Determining - Missouri Division of
We are now prepared to relate air to heat Suppose we are supplying 300 CFM to a heater The air enters at 70° F and leaves at 120° F How much heat has the
[PDF] HVAC FORMULAS TON OF REFRIGERATION - The amount of heat
CONVERTING BTU to KW: 3413 BTU's = 1 KW Example: A 100,000 BTU/hr oil or gas furnace (100,000 ÷ 3413 = 29 3 KW) COULOMB = 6 24 X 1018
[PDF] Determining a building energy needs
Buildings Many States have made their code even more stringent Heating needed- 117,00 btus; 19 34 btu/ sq ft • Cooling needed- 13 5 Tons; 448 cfm/ sq ft
[PDF] Guide to Home Heating and Cooling
There are many different kinds of heating and cooling systems you can use in accepted old estimate is that an HVAC unit should provide one ton (12,000 Btu)
[PDF] how many capabilities are there in adobe analytics
[PDF] how many carbs in buffalo wild wings fries
[PDF] how many catholic churches in chicago
[PDF] how many cctv cameras in france
[PDF] how many cents in a dollar
[PDF] how many checks can you cash at once
[PDF] how many children use social media
[PDF] how many chinese students in italy
[PDF] how many coats of zinsser 123 primer
[PDF] how many college students take a foreign language
[PDF] how many concorde planes crashed
[PDF] how many countries share a border with france in total?
[PDF] how many crossfit gyms are there
[PDF] how many curved surfaces does a cylinder have
S
IZING HVAC EQUIPMENT
© CLEAResult, 2014
The goal of all HVAC equipment sizing is to find the best match between the house and the equipment. Optimal size is the best match, or balance, between the rate of heat loss or heat gain of the house and the capacity of the HVAC equipment. W hat Is Meant by Equipment Sizing?The heating or cooling load of the
house is how many BTUs/hr the house requires to maintain the required indoor temperature at design conditionsTypical homes have heat loss rates of
between 20,000 BTUs/hr and 80,000 BTUs/hr and cooling loads of between 12,000 Btus/hr and 40,000Btus/hr
f initions: Heating/Cooling LoadTo be warm in winter
To be cool in summer
the Customer WantsINPUTS:
Weather data
Square footages
Insulation levels
U Values glass
SHGC ACHDuct multipliers
OUTPUTS:
Heating/cooling
loadsINPUTS:Heating/cooling
loadsCapacity tables
Fan data
OUTPUTS:
Unit selectionINPUTS:
TELFan data
OUTPUTS:
Friction rate
Duct sizes
Lower front-end
costsGreater comfort
Lower energy use
I NP U T S I NP U T S I NP U T S Lo w e r fr o n t e n dManual
JManual
SManual
DBenefits
ACCA HVAC Design Process
R-0 R-7 R-11 R-19 R-27 R-30 R-38
S QF E E T O FA T T I C Sq. Feet. Of Attic at Various R- Values Needed to Create One Ton of Heating load (12,000 Btus/hr.) Boise Idaho t he R-value that Matters...05,000
R-0 R-7 R-11 R-19 R-27 R-30 R-38
BTU'S Per Hour of Heat Loss
BTUs Through 2,000 sq of Attic with Various R
Values: Boise Idaho
tThe Square Feet
M anual J Heating Load InputsIt's pretty simple
Sq. Footage and R
R RU values
Duct Multiplier
ACH and ACH
andVentilation
Limited Range in New
Construction!It's an educated guess!
This is the old
Greek Formula:
40K60K
80K
100K
K 120K