Page 1. bar psi. kPa/MPa. Kg/cm2 100 MPa. 1019.579. 1000000. Pressure Conversion Table. We're the experts... ...talk to us 01628 531166.
pdf pressure card
Pressure gauge
1 MPa. 18. For high-pressure applications. PAGL-HP3. G1/4. 63. 0 60 bar and. 0 ... 6 MPa. 0 ... 870 psi pagl. Precision pressure gauge. MAP.
Pressure gauge
1 MPa. 18. For high-pressure applications. PAGL-HP3. G1/4. 63. 0 60 bar and. 0 ... 6 MPa. 0 ... 870 psi pagl. Precision pressure gauge.
Tensile strength/yield strength (TS/YS) ratios of high-strength steel
reinforcement whereas Grade 420 MPa bars are the maximum limit of yield strength of 1964
Pressure indication in bar/MPa or bar/psi. – Two-colour scale 1). Type. Material number. 0. ABZMM 00- 0 BAR/MPA-R/B-G. R900072004.
re
with Full Face. All S.S. Diaphragm Seal x. 1/2” Process Connection. Female Thread. UNITED INSTRUMENT. LIQUID FILLED PRESSURE GAUGES (BAR PSI & MPA).
SS w
Filter regulators MS-LFR-B
Adapter for EN pressure gauge 1/8 without pressure gauge. 010. Alternative pressure gauge scale. MS pressure gauge. BAR bar. MPA. MPa.
Large turndown ratio of up to 100:1 (0.6 MPa 6 bar
SS DS EN
1.A single stage reciprocating compressor takes 1m The compressor sucks air at 1 bar and 27 ... intake pressure and temperature of air 0.1MPa and 16.
HE ALLUnits
Units Conversion Tables
http://www.easymore.com.tw/catalogues/Conversion%20Tables.pdf
247741
Data Sheet SS/265DS-EN_06
Model 265DS Differential
Series 2600T Pressure Transmitters
Engineered solutions for all
applications Selectable maximum operating pressure up to 41 MPa,
5,945 psi
Base accuracy
" ± 0.04 %
Span limits
" 0.05 ... 10,000 kPa; 0.2 in H2O up to 1,450 psi High-performance transmitter and smallest possible measuring ranges Proven sensor technology together with state-of-the-art digital technology " Large turndown ratio of up to 100:1
Comprehensive selection of sensors
" Optimized performance and stability
5-year stability
Flexible configuration options
" On device using control buttons in combination with LCD display, handheld terminal, or PC user interface
Various communication protocols available
" Enables integration into HART®, PROFIBUS PA, and
FOUNDATION fieldbus platforms
" Upgrade options thanks to interchangeable electronics with automatic configuration Full compliance with Pressure Equipment Directive (PED) category III
Contents
Series 2600T Pressure Transmitters 265DS SS/265DS-EN_06 For differential pressure, selectable maximum operating pressure up to 41 MPa, 5,945 psi 2
Contents
1 Functional specifications ........................................................................
...........................................................3
2 Operating limits........................................................................
...........................................................................3
2.1 Temperature limits in °C (°F)........................................................................
..................................................3
2.2 Pressure limits........................................................................
........................................................................4
3 Environmental limits........................................................................
...................................................................4
4 Potentially explosive atmospheres ........................................................................
...........................................5
5 Electrical data and options........................................................................
.........................................................8
5.1 HART digital communication and 4 ... 20 mA output current.........................................................................8
5.2 PROFIBUS PA output........................................................................
............................................................9
5.3 FOUNDATION fieldbus output........................................................................
...............................................9
6 Measuring accuracy........................................................................
..................................................................10
7 Operating influences........................................................................
.................................................................11
8 Technical specification........................................................................
.............................................................12
9 Configuration........................................................................
.............................................................................13
9.1 Transmitter with HART communication and 4 ... 20 mA output current.......................................................13
9.2 Transmitter with PROFIBUS PA communication........................................................................
.................13
9.3 Transmitter with FOUNDATION fieldbus communication........................................................................
Data Sheet SS/265DS-EN_06
Model 265DS Differential
Series 2600T Pressure Transmitters
Engineered solutions for all
applications Selectable maximum operating pressure up to 41 MPa,
5,945 psi
Base accuracy
" ± 0.04 %
Span limits
" 0.05 ... 10,000 kPa; 0.2 in H2O up to 1,450 psi High-performance transmitter and smallest possible measuring ranges Proven sensor technology together with state-of-the-art digital technology " Large turndown ratio of up to 100:1
Comprehensive selection of sensors
" Optimized performance and stability
5-year stability
Flexible configuration options
" On device using control buttons in combination with LCD display, handheld terminal, or PC user interface
Various communication protocols available
" Enables integration into HART®, PROFIBUS PA, and
FOUNDATION fieldbus platforms
" Upgrade options thanks to interchangeable electronics with automatic configuration Full compliance with Pressure Equipment Directive (PED) category III
Contents
Series 2600T Pressure Transmitters 265DS SS/265DS-EN_06 For differential pressure, selectable maximum operating pressure up to 41 MPa, 5,945 psi 2
Contents
1 Functional specifications ........................................................................
...........................................................3
2 Operating limits........................................................................
...........................................................................3
2.1 Temperature limits in °C (°F)........................................................................
..................................................3
2.2 Pressure limits........................................................................
........................................................................4
3 Environmental limits........................................................................
...................................................................4
4 Potentially explosive atmospheres ........................................................................
...........................................5
5 Electrical data and options........................................................................
.........................................................8
5.1 HART digital communication and 4 ... 20 mA output current.........................................................................8
5.2 PROFIBUS PA output........................................................................
............................................................9
5.3 FOUNDATION fieldbus output........................................................................
...............................................9
6 Measuring accuracy........................................................................
..................................................................10
7 Operating influences........................................................................
.................................................................11
8 Technical specification........................................................................
.............................................................12
9 Configuration........................................................................
.............................................................................13
9.1 Transmitter with HART communication and 4 ... 20 mA output current.......................................................13
9.2 Transmitter with PROFIBUS PA communication........................................................................
.................13
9.3 Transmitter with FOUNDATION fieldbus communication........................................................................