[PDF] EN / ACS880-01 hardware manual - ABB
3 jui 2022 · ACS880-01 drives Hardware manual Table of contents 1 Safety instructions 4 Mechanical installation 6 Electrical installation –
EN ACS HW S
[PDF] Variateurs single drive ACS880 - ABB
VARIATEURS EN COFFRET POUR MONTAGE MURAL ACS880-01 24 – 27 VARIATEURS EN ARMOIRE ACS880-07 28 – 33 VARIATEURS RÉGÉNÉRATIFS ACS880-11 ACS880-17
Catalogue variateur ACS AFA RevO FR
[PDF] ACS880-01 (055 to 250 kW) HW E - Moteurs électriques SIE
Drive hardware manuals and guides Code (English) Code (FR) ACS880-01 hardware manual 3AUA0000078093 3AUA0000103705 ACS880-01 quick installation guide
Manuel Instal FR ACS
[PDF] EN / ACS880-01 drives (055 to 250 kW 075 to 350 hp) hardware
ACS880-01 drives recycling instructions and environmental information 3AUA0000149383 Drive firmware manuals and guides ACS880 primary control program
abb acs manual
[PDF] ACS880-Drive-Hardware-Manualpdf
ACS880-01 marine type-approved drives (option +C132) supplement 3AXD50000010521 Drive firmware manuals and guides ACS880 primary control program firmware
ACS Drive Hardware Manual
[PDF] Variateurs single drive ACS880-01 055 à 250 kW / 075 à 350 hp
Le variateur ACS880-01 fait partie intégrante de notre offre 100 compatible qui pilote quasiment tous les types de moteurs CA s'intègre
PEI ABB Variateur DS
[PDF] Wall-mounted single drives ACS880-01
The type approved ACS880-01 marine drive provides advanced reliability and availability at sea The drive fulfills marine and offshore requirements and the
ID SPE v ACS TechnicalData
[PDF] Variateurs single drive ACS880 055 à 250 kW Catalogue
Bâti sur l'architecture commune à tous les variateurs ABB l'ACS880-01 en coffret pour montage mural répond avec précision aux besoins de secteurs d'activités
Doc commercial ACS g C A n C A ral
[PDF] ACS880-01 Wall-mounted Single Drives Data sheet
ACS880-01 Wall-mounted Single Drives Data sheet Input ratings Input voltage range 208-240 V; 380-500 V; 525-690 V Input voltage tolerance +10 /-15
abb acs datasheet
ACS880-01 Wall-mounted Single Drives
Data sheet
Input ratingsInput voltage range 208-240 V; 380-500 V; 525-690 VInput voltage tolerance +10%/-15%
PhaseThree phase
Frequency47 to 63 Hz
Short circuit rating (UL 508c)
100,000 rms symmetrical amperes up to 600 V when input cables protected by class T
or similar type fusesOutput ratings
Horsepower 0.75 - 350 HP @ 480 VAC
0.75 - 100 HP @ 230 VAC
5 - 250 HP @ 575/690 VAC
Overload capacity
Heavy duty = 150% for 60 seconds every 5 minutes
Light duty = 110% for 60 seconds every 5 minutes
Frequency0-500 Hz
Voltage0 to maximum input voltage (RMS)
Motor types
Asynchronous AC induction motors, permanent magnet synchronous motors and AC induction servomotorsProtective features
Overcurrent Excessive output current
DC overvoltage High DC bus
OvertempDrive heatsink above operating temperature, max ambient temperature exceededShort circuit Short on motor output terminals
UndervoltageLow voltage on drive input
Loss of reference Analog input programmed for 4-20 ma but signal less than 4 ma Motor overtemp Excessive estimated motor temperature Loss of keypad Drive will trip if under keypad control and keypad communication is lost Motor stallMotor cannot achieve commanded speed due to excessive load Ground faultGround fault detected in motor or motor cablingMotor phase faultLoss at one of the motor phases
Environmental
Temperature0 to 40°C (32 to 104°F). 0 to 55°C (32 to 131°F) w/ dera te. No frost allowed.CoolingForced air
EnclosureUL type 1 (IP21), UL type 12 (IP55)
AltitudeSea level to 3300 ft. (1000 m) Derate 1% per 330 ft. (100 m) up to 13,128 ft. (4000 m)
Humidity0 to 95% RH non-condensing
VibrationMax. 1 mm (0.04 in.) (5 to 13.2 Hz), max. 7 m/s2 (23 ft/s2) (13.2 to 100 Hz) sinusoidalKeypad display
Display LCD graphical
Keys8 key keypad with tactile response
Functions
Output status monitoring, digital speed control, parameter setting and display, diagnostic and fault log display, motor run, local/remote toggle, graphical monitoring Remote mount Keypad may be mounted up to 9 ft. using appropriate cable (see Options for kit)TripLast three faults stored in fault history
Control
specificationsSwitching frequency 2.7 kHz (average)Accel/decel 0-1800 seconds
Speed control accuracy 10% of motor slip, DTC, no encoder Skip frequencies Three configurable bands 0-max speed PC setup software Drive composer, drive composer proMaximum output frequency 500 Hz
Selectable operating modes2-Wire, 3-Wire, Motor Potentiometer, Hand/Auto, PIDAnalog inputs
Two differential current or voltageŝ
Resolution11 bit + sign bit
Analog outputs
Two current outputsŝ
Frequency range0 to 300 Hz
Resolution11 bit + sign bit
Digital inputs
Six digital inputs15 V...24 VDC with internal or external supply Input impedance Pull-up or pull-down (PNP or NPN) (DI1 to DI5); NPN (DI6) Filtering.04 ms hardware filter, digital filtering up to 8 msDigital outputs
Three relay outputs Form C
Maximum switching voltage250 VAC/30 VDC
Maximum continuous current2 A/30 VDC or 250 VAC
SafetySafe torque off (STO) STO standard input; 17...30 VDC, 55 mA0.75 - 100 HP
208 - 240 VAC
0.75 - 350 HP
380 - 500 VAC 3 Phase - 50/60 Hz
5 - 200 HP
525 - 690 VAC
9 - 6 ACS880, industrial drive CONFIDENTIAL: DO NOT COPY. DO NOT DISTRIBUTE Effective: 07/15/2015
U N = 240 VAC (range 208 to 240 VAC). Power ratings are valid at nominal voltage 230 VAC, 60 HzType code
Nominal ratings
Frame sizeUL type 1 (IP21) list priceUL type 12 (IP55) +B056 list priceLight duty (110% overload for 1 min)Heavy duty (150% overload for 1 min) I Ld A P Ld HPP Ld kWI 2Hd A P Hd HPP Hd kW ACS880-01-04A6-24.410.753.70.750.55R1$1,764 $2,137ACS880-01-06A6-26.31.51.14.610.75R1$1,779 $2,155
ACS880-01-07A5-27.121.56.61.51.1R1$1,814 $2,190
ACS880-01-10A6-210.132.27.521.5R1$1,831 $2,211
ACS880-01-16A8-2165410.633R2$1,961 $2,364
ACS880-01-24A3-223.17.55.516.854R2$2,262 $2,741
ACS880-01-031A-229.3107.524.37.55.5R3$2,590 $3,160ACS880-01-046A-244151138107.5R4$3,188 $3,889
ACS880-01-061A-2582015451511R4$3,855 $4,703
ACS880-01-075A-2712518.5612015R5$4,709 $5,651
ACS880-01-087A-2833022722518.5R5$5,633 $6,760
ACS880-01-115A-21094030873022R6$7,344 $8,770
ACS880-01-145A-213850371054030R6$8,803 $10,496
ACS880-01-170A-216260451455037R7$10,566 $12,541
ACS880-01-206A-219675551696045R7$13,201 $15,517
ACS880-01-274A-2
3260100752137555R8$15,724 $19,121
ACS880-01 Wall-mounted Single Drives
List prices
Notes:
3 For drives with enclosure class UL type 12 (IP55), the ratings apply at 40 o C ambient temperature. At higher temperature the derating is 1%/1 oC from 40 to 45
oC and 2.5%/1
oC from
45 to 55
o CGeneral Notes:
Ratings apply at an ambient temperature of 40°C (104°F) unless otherwise noted.To achieve the rated motor power given in the table, the rated current of the drive must be higher than or equal to the rated motor current.
I LD Continuous rms output current allowing 110% overload for 1 minute every 5 minutes. P LDTypical motor power in light-overload use.
I HD Continuous rms output current allowing 150% overload for 1 minute every 5 minutes. P HDTypical motor power in heavy-duty use.
ACS880, industrial drive 9 - 7Effective: 07/15/2015 CONFIDENTIAL: DO NOT COPY. DO NOT DISTRIBUTE U N = 500 VAC (range 380 to 500 VAC). Power ratings are valid at nominal voltage 480 VAC, 60 HzType code
Nominal ratings
Frame sizeUL type 1 (IP21) list priceUL type 12 (IP55) +B056 list priceLight duty (110% overload for 1 min)Heavy duty (150% overload for 1 min) I Ld A P Ld HPP Ld kWI 2Hd A P Hd HPP Hd kW ACS880, industrial drive 9 - 5Effective: 07/15/2015 CONFIDENTIAL: DO NOT COPY. DO NOT DISTRIBUTEACS880-01 Wall-mounted Single Drives
Data sheet
Input ratingsInput voltage range 208-240 V; 380-500 V; 525-690 VInput voltage tolerance +10%/-15%
PhaseThree phase
Frequency47 to 63 Hz
Short circuit rating (UL 508c)
100,000 rms symmetrical amperes up to 600 V when input cables protected by class T
or similar type fusesOutput ratings
Horsepower 0.75 - 350 HP @ 480 VAC
0.75 - 100 HP @ 230 VAC
5 - 250 HP @ 575/690 VAC
Overload capacity
Heavy duty = 150% for 60 seconds every 5 minutes
Light duty = 110% for 60 seconds every 5 minutes
Frequency0-500 Hz
Voltage0 to maximum input voltage (RMS)
Motor types
Asynchronous AC induction motors, permanent magnet synchronous motors and AC induction servomotorsProtective features
Overcurrent Excessive output current
DC overvoltage High DC bus
OvertempDrive heatsink above operating temperature, max ambient temperature exceededShort circuit Short on motor output terminals
UndervoltageLow voltage on drive input
Loss of reference Analog input programmed for 4-20 ma but signal less than 4 ma Motor overtemp Excessive estimated motor temperature Loss of keypad Drive will trip if under keypad control and keypad communication is lost Motor stallMotor cannot achieve commanded speed due to excessive load Ground faultGround fault detected in motor or motor cablingMotor phase faultLoss at one of the motor phases
Environmental
Temperature0 to 40°C (32 to 104°F). 0 to 55°C (32 to 131°F) w/ dera te. No frost allowed.CoolingForced air
EnclosureUL type 1 (IP21), UL type 12 (IP55)
AltitudeSea level to 3300 ft. (1000 m) Derate 1% per 330 ft. (100 m) up to 13,128 ft. (4000 m)
Humidity0 to 95% RH non-condensing
VibrationMax. 1 mm (0.04 in.) (5 to 13.2 Hz), max. 7 m/s2 (23 ft/s2) (13.2 to 100 Hz) sinusoidalKeypad display
Display LCD graphical
Keys8 key keypad with tactile response
Functions
Output status monitoring, digital speed control, parameter setting and display, diagnostic and fault log display, motor run, local/remote toggle, graphical monitoring Remote mount Keypad may be mounted up to 9 ft. using appropriate cable (see Options for kit)TripLast three faults stored in fault history
Control
specificationsSwitching frequency 2.7 kHz (average)Accel/decel 0-1800 seconds
Speed control accuracy 10% of motor slip, DTC, no encoder Skip frequencies Three configurable bands 0-max speed PC setup software Drive composer, drive composer proMaximum output frequency 500 Hz
Selectable operating modes2-Wire, 3-Wire, Motor Potentiometer, Hand/Auto, PIDAnalog inputs
Two differential current or voltageŝ
Resolution11 bit + sign bit
Analog outputs
Two current outputsŝ
Frequency range0 to 300 Hz
Resolution11 bit + sign bit
Digital inputs
Six digital inputs15 V...24 VDC with internal or external supply Input impedance Pull-up or pull-down (PNP or NPN) (DI1 to DI5); NPN (DI6) Filtering.04 ms hardware filter, digital filtering up to 8 msDigital outputs
Three relay outputs Form C
Maximum switching voltage250 VAC/30 VDC
Maximum continuous current2 A/30 VDC or 250 VAC
SafetySafe torque off (STO) STO standard input; 17...30 VDC, 55 mA0.75 - 100 HP
208 - 240 VAC
0.75 - 350 HP
380 - 500 VAC 3 Phase - 50/60 Hz
5 - 200 HP
525 - 690 VAC
9 - 6 ACS880, industrial drive CONFIDENTIAL: DO NOT COPY. DO NOT DISTRIBUTE Effective: 07/15/2015
U N = 240 VAC (range 208 to 240 VAC). Power ratings are valid at nominal voltage 230 VAC, 60 HzType code
Nominal ratings
Frame sizeUL type 1 (IP21) list priceUL type 12 (IP55) +B056 list priceLight duty (110% overload for 1 min)Heavy duty (150% overload for 1 min) I Ld A P Ld HPP Ld kWI 2Hd A P Hd HPP Hd kW ACS880-01-04A6-24.410.753.70.750.55R1$1,764 $2,137ACS880-01-06A6-26.31.51.14.610.75R1$1,779 $2,155
ACS880-01-07A5-27.121.56.61.51.1R1$1,814 $2,190
ACS880-01-10A6-210.132.27.521.5R1$1,831 $2,211
ACS880-01-16A8-2165410.633R2$1,961 $2,364
ACS880-01-24A3-223.17.55.516.854R2$2,262 $2,741
ACS880-01-031A-229.3107.524.37.55.5R3$2,590 $3,160ACS880-01-046A-244151138107.5R4$3,188 $3,889
ACS880-01-061A-2582015451511R4$3,855 $4,703
ACS880-01-075A-2712518.5612015R5$4,709 $5,651
ACS880-01-087A-2833022722518.5R5$5,633 $6,760
ACS880-01-115A-21094030873022R6$7,344 $8,770
ACS880-01-145A-213850371054030R6$8,803 $10,496
ACS880-01-170A-216260451455037R7$10,566 $12,541
ACS880-01-206A-219675551696045R7$13,201 $15,517
ACS880-01-274A-2
3260100752137555R8$15,724 $19,121
ACS880-01 Wall-mounted Single Drives
List prices
Notes:
3 For drives with enclosure class UL type 12 (IP55), the ratings apply at 40 o C ambient temperature. At higher temperature the derating is 1%/1 oC from 40 to 45
oC and 2.5%/1
oC from
45 to 55
o CGeneral Notes:
Ratings apply at an ambient temperature of 40°C (104°F) unless otherwise noted.To achieve the rated motor power given in the table, the rated current of the drive must be higher than or equal to the rated motor current.
I LD Continuous rms output current allowing 110% overload for 1 minute every 5 minutes. P LDTypical motor power in light-overload use.
I HD Continuous rms output current allowing 150% overload for 1 minute every 5 minutes. P HDTypical motor power in heavy-duty use.
ACS880, industrial drive 9 - 7Effective: 07/15/2015 CONFIDENTIAL: DO NOT COPY. DO NOT DISTRIBUTE U N = 500 VAC (range 380 to 500 VAC). Power ratings are valid at nominal voltage 480 VAC, 60 HzType code
Nominal ratings
Frame sizeUL type 1 (IP21) list priceUL type 12 (IP55) +B056 list priceLight duty (110% overload for 1 min)Heavy duty (150% overload for 1 min) I Ld A P Ld HPP Ld kWI 2Hd A P Hd HPP Hd kW- acs880-01 manual français
- acs880-01 hardware manual
- acs880-01 catalogue
- acs880-01 manual svenska
- acs880-01 manual
- acs880-01 firmware manual
- acs880-01 dimensions
- acs880-01 datasheet