LISTE D'APPLICATIONS PEDAGOGIQUES CYCLES 2 & 3
Mathboard : Application permettant de s'entraîner en mathématiques Une application pour faire des dictées de mots avec des enfants du CP au CM2. Les.
liste appli c c mv
DIRECCIÓN GENERAL DE ECONOMÍA SOCIAL Y AUTÓNOMOS C
C/ Jacinto Benavente 2 - C.P.: 47195 - Arroyo de la Encomienda (Valladolid). MODELO DE SUBSANACIÓN Y/O APORTACIÓN DE DATOS.
IAPA Subsanacion @ v ?blobheader=application/pdf;charset=UTF &blobheadername =Cache Control&blobheadername =Expires&blobheadername =Site&blobheadername =Content Disposition&blobheadervalue =no store,no cache,must revalidate&blobheadervalue = &blobheadervalue =Portal Informador&blobheadervalue =inline; filename=tramite &blobnocache=true
DSA 1-CP: Application Supplement-Coolaborative Process
CONSULTANT REQUEST DETAILS. 11. Is school district requesting use of DSA consultant for collaborative services? Yes. No. 12.
DSA CP
Application Note 600V CoolMOS CP
12 févr. 2007 MOSFET Selection for the Application Based on Loss Balance . ... Target applications for CoolMOSTM CP are server and telecom power supplies ...
Infineon ApplicationNote MOSFET CoolMOS CP AN v EN ?fileId=db a b b ac a
Consultation Paper
EBA/CP/2015/15. 22 September 2015. Consultation Paper. Guidelines on the application of the definition of default under. Article 178 of Regulation (EU) 575/
EBA CP (CP on GL on the application of the definition of default)
Solicitud de Número de Identidad de Extranjero (NIE) y Certificados
C.P.. Provincia. Teléfono móvil. E-mail. Representante legal en su caso. DNI/NIE/PAS. Título(4). 2) DATOS DEL REPRESENTANTE A EFECTOS DE PRESENTACIÓN DE LA
Formulario NIE y certificados
on the application of the existing Joint Committee Guidelines on
27 mars 2018 CP ON THE APPLICATION OF THE JC GUIDELINES ON COMPLAINTS-HANDLING TO THE NEW INSTITUTIONS. UNDER MCD AND PSD2.
e e aeef befaa e
Liste des applications éducatives suggérées aux parents Tablettes
exercices de maths et français pour les classes de. CP CE1
appli parents fevrier
vacon®20 cp/x multipurpose application manual
26 janv. 2015 MULTIPURPOSE APPLICATION. The VACON. ®. 20 CP/X drive contains a preloaded application for instant use. The parameters of this application ...
Vacon CP X Multipurpose Application Manual DPD H
Application for Custom Plates
CP-30 (9/20). П Check П Money Order Make check or money order payable to “Commissioner of Motor Vehicles”. Name (as it appears on credit card).
cp
20 cp/x
ac drives multipurpose application manual vacon • 0 Service support: find your nearest Vacon service center at www.vacon.com INDEXDocument ID: DPD00536H
Order code: DOC-APP03982+DLUK
Rev. H
Version release date: 26.1.15
Corresponds to application package ACIT1075V111.vcx1. Multipurpose Application.................................................................................2
1.1 Specific functions of Vacon Multipurpose application...................................................... 2
1.2 Example of control connections ....................................................................................... 3
1.3 Optional boards................................................................................................................. 5
1.3.1 Option board installation................................................................................................... 82. Description of Groups....................................................................................12
2.1 Keypad Reference: Menu REF ........................................................................................ 12
2.2 Monitor group: menu MON ............................................................................................. 13
2.3 Parameter Groups: Menu PAR ....................................................................................... 14
2.3.1 Group Basic Parameters: Menu PAR G1 ........................................................................ 15
2.3.2 Group Advanced Settings: Menu PAR G2........................................................................ 16
2.3.3 Group Analogue inputs: Menu PAR G3 ........................................................................... 18
2.3.4 Group Digital inputs: Menu PAR G4................................................................................ 19
2.3.5 Group Digital outputs: Menu PAR G5.............................................................................. 21
2.3.6 Group Analogue outputs: Menu PAR G6......................................................................... 22
2.3.7 Group Supervisions: Menu PAR G7................................................................................. 23
2.3.8 Group Motor Control: Menu PAR G8............................................................................... 24
2.3.9 Group Protections: Menu PAR G9................................................................................... 26
2.3.10 Group Autoreset: Menu PAR G10.................................................................................... 29
2.3.11 Group Fieldbus: Menu PAR G11...................................................................................... 30
2.3.12 Group PID-controller: Menu Par G12 ............................................................................. 31
2.3.13 Group temperature measurement: Menu Par G13........................................................ 32
2.4 System parameters, Faults and History faults: Menu SYS/FLT..................................... 333. Parameter description...................................................................................36
3.1 Basic Parameters............................................................................................................36
3.2 Advanced settings ...........................................................................................................37
3.3 Analogue inputs............................................................................................................... 46
3.4 Digital inputs ................................................................................................................... 50
3.5 Digital outputs................................................................................................................. 52
3.6 Analogue Output..............................................................................................................54
3.7 Supervisions.................................................................................................................... 55
3.8 Motor control................................................................................................................... 57
3.9 Protections...................................................................................................................... 61
3.10 Autoreset......................................................................................................................... 67
3.11 Fieldbus........................................................................................................................... 69
3.11.1 Fieldbus mapping............................................................................................................ 70
3.12 PID Control...................................................................................................................... 73
3.13 Temperature measurement ........................................................................................... 754. Fault tracing..................................................................................................78
vacon • 1Multipurpose Application vacon • 2
Service support: find your nearest Vacon service center at www.vacon.com 11. MULTIPURPOSE APPLICATION
The VACON
20 CP/X drive contains a preloaded application for instant use.
The parameters of this application are listed in chapter 2.3 of this manual and explained in more detail in chapter 2.1.1 Specific functions of Vacon Multipurpose application
The Vacon Multipurpose allows flexible use of VACON20 CP/X frequency converters.
Features
The drive can be controlled through I/O terminals, a fieldbus or the optional keypad.Two pro- grammable control places and sources for the frequency reference are available, for easy lo- cal/remote control. Frequency reference can be direct (analogue input, preset speeds, motor potentiometer, field- bus) or controlled by the internal PID regulator. PID setpoint and actual value are totally programmable. A "sleep" function is available, with possibility of pressure boost and check of the losses before entering the stand-by state. All the functionalities can be controlled through a fieldbus. The motor identification function allows automatic optimization of the voltage/frequency curve, for a optimal torque response also at low motor speed. It is possible to install one optional board for I/O or fieldbus expansion. Both AC induction motor and PM motor can be controlled. vacon • 3 Multipurpose Application 11.2 Example of control connections
Table 1. Connection example, standard I/O terminals.Standard I/O terminals
TerminalSignalDefault
ARS485Serial bus, negative
BRS485Serial bus, positive
1+10 Vref Reference output
2AI1+Analogue input,
voltage or currentSelectable with DIP switches, see VACON
20 CP/X
Installation ManualVoltage
3AI1-/GNDAnalogue input common
(current)624Vout 24V aux. voltage
7DIN COM Digital input common
8DI1 Digital input 1 Start FWD
9DI2 Digital input 2 Start REV
10DI3 Digital input 3Preset
Speed B0
4AI2+Analogue input,
voltage or current*Current5AI2-/GNDAnalogue input common
(current)13DO1- Digital Output Common
14DI4 Digital input 4Preset
Speed B1
15DI5 Digital input 5Fault
reset16DI6 Digital input 6 Ramp 2
18AO1+ Analogue signal (+output)Output
frequency20DO1+ Digital output +Ready
Reference potentiometer
vacon20 cp/x
ac drives multipurpose application manual vacon • 0 Service support: find your nearest Vacon service center at www.vacon.com INDEXDocument ID: DPD00536H
Order code: DOC-APP03982+DLUK
Rev. H
Version release date: 26.1.15
Corresponds to application package ACIT1075V111.vcx1. Multipurpose Application.................................................................................2
1.1 Specific functions of Vacon Multipurpose application...................................................... 2
1.2 Example of control connections ....................................................................................... 3
1.3 Optional boards................................................................................................................. 5
1.3.1 Option board installation................................................................................................... 82. Description of Groups....................................................................................12
2.1 Keypad Reference: Menu REF ........................................................................................ 12
2.2 Monitor group: menu MON ............................................................................................. 13
2.3 Parameter Groups: Menu PAR ....................................................................................... 14
2.3.1 Group Basic Parameters: Menu PAR G1 ........................................................................ 15
2.3.2 Group Advanced Settings: Menu PAR G2........................................................................ 16
2.3.3 Group Analogue inputs: Menu PAR G3 ........................................................................... 18
2.3.4 Group Digital inputs: Menu PAR G4................................................................................ 19
2.3.5 Group Digital outputs: Menu PAR G5.............................................................................. 21
2.3.6 Group Analogue outputs: Menu PAR G6......................................................................... 22
2.3.7 Group Supervisions: Menu PAR G7................................................................................. 23
2.3.8 Group Motor Control: Menu PAR G8............................................................................... 24
2.3.9 Group Protections: Menu PAR G9................................................................................... 26
2.3.10 Group Autoreset: Menu PAR G10.................................................................................... 29
2.3.11 Group Fieldbus: Menu PAR G11...................................................................................... 30
2.3.12 Group PID-controller: Menu Par G12 ............................................................................. 31
2.3.13 Group temperature measurement: Menu Par G13........................................................ 32
2.4 System parameters, Faults and History faults: Menu SYS/FLT..................................... 333. Parameter description...................................................................................36
3.1 Basic Parameters............................................................................................................36
3.2 Advanced settings ...........................................................................................................37
3.3 Analogue inputs............................................................................................................... 46
3.4 Digital inputs ................................................................................................................... 50
3.5 Digital outputs................................................................................................................. 52
3.6 Analogue Output..............................................................................................................54
3.7 Supervisions.................................................................................................................... 55
3.8 Motor control................................................................................................................... 57
3.9 Protections...................................................................................................................... 61
3.10 Autoreset......................................................................................................................... 67
3.11 Fieldbus........................................................................................................................... 69
3.11.1 Fieldbus mapping............................................................................................................ 70
3.12 PID Control...................................................................................................................... 73
3.13 Temperature measurement ........................................................................................... 754. Fault tracing..................................................................................................78
vacon • 1Multipurpose Application vacon • 2
Service support: find your nearest Vacon service center at www.vacon.com 1