BULLETIN OFFICIEL DES IMPÔTS
22 ?ub 2012 B.O.I.. Version imprimée: I.S.S.N. 0982 801 X. Direction générale des finances ... 5 F-5-12 ... NOR : BCR Z 12 00013 J. Bureau GF-1A.
DEÜ MÜHEND?SL?K FAKÜLTES? FEN ve MÜHEND?SL?K DERG?S?
1-12 Ocak 2000. ATIKSU M?KTARI VE BO?5 K?RL?L?K YÜKÜNÜN HAVALANDIRMA Yap?lan çal??malar sonucunda; BO?. 5.
SU K?RL?L??? KONTROLÜ YÖNETMEL???
f) Benzer nitelikte at?ksu üreten endüstriler ve yerle?imler için ortak at?ksu a) Kirlilik yükü ham BO?5 olarak 5-120 kg/gün aras?nda (E?de?er nüfus 84 ...
ATIKSU ARITMA TES?SLER? TASARIM REHBER?
12. 2.2.3. Kavramsal Tasar?m (veya baz? hallerde Avan Proje) . ve standart de?er olarak 65°F (yakla??k 18°C) ile 5 gün de?erlerinin kullan?lmas?na karar.
HAVALANDIRMA HAVUZU
15 Nis 2021 oldu?undan bunun BO?. 5 cinsinden e?de?eri a?a??da hesaplanm??t?r. •. Biyolojik olarak ayr??abilen k?s?m = 06 * 20 mg/lt = 12.
DEÜ MÜHEND?SL?K FAKÜLTES? FEN ve MÜHEND?SL?K DERG?S?
1-12 Ocak 2000. ATIKSU M?KTARI VE BO?5 K?RL?L?K YÜKÜNÜN HAVALANDIRMA Yap?lan çal??malar sonucunda; BO?. 5.
HAVALANDIRMA HAVUZU
19 Mar 2020 oldu?undan bunun BO?. 5 cinsinden e?de?eri a?a??da hesaplanm??t?r. •. Biyolojik olarak ayr??abilen k?s?m = 06 * 20 mg/lt = 12.
106 5. B?YOLOJ?K ARITMA H?zl? nüfus art??? ve endüstrile?me
12-16. 7-10. 1-5. 08-1
GÖKPINAR VE ÇÜRÜKSU ÇAYLARININ K?RL?L?K PARAMETRE VE
kimyasal oksijen ihtiyac? (KO?) ve biyolojik oksijen ihtiyac? (BO?5) 185. 16
106 5. B?YOLOJ?K ARITMA H?zl? nüfus art??? ve endüstrile?me
27 Kas 2019 f = BO?5'den BO?L'ye dönü?üm faktörü. Nitrifikasyon reaksiyonunun da sistemde gerçekle?mesi durumunda toplam oksijen.
DEÜ MÜHENDSLK FAKÜLTES
FEN ve MÜHENDSLK DERGS
Cilt: 2 Sayı: 1 sh. 1-12 Ocak 2000
ATIKSU MKTARI VE BO
5KRLLK YÜKÜNÜN, HAVALANDIRMA
HAVUZU LK YATIRIM VE ENERJ MALYETLERNE OLAN ETKLERNNNCELENMES
(INVESTIGATION OF EFFECTS OF FLOWRATE AND BOD 5LOADING ON
INVESTMENT AND ENERGY COSTS OF AERATION TANK)
Mustafa DERMENC*, Ahmet ALTIN*, Süreyya ALTIN*
ÖZET / ABSTRACT
Günümüzde atıksu arıtma tesislerinin tasarımında, atıksu debileri ve kirlilik yükleri genellikle yeterince
inceleme yapılmadan, belli emniyet payları bırakılarak tahmin edilmektedir. Ayrıca bu tasarımlarda, tesisin
edilen atıksu debileri ve kirlilik yüklerinin ve projelendirme parametrelerinin havalandırma havuzu ilk yatırım
ve enerji maliyetlerine olan etkileri aratırılmıtır.
Yapılan çalımalar sonucunda; BO5
, debi, F/M ve UAKM miktarındaki deiimlerin inaat maliyetlerini 5 A * B eklinde bir ilikinin mevcut olduu belirlenmitir. Burada verilen A ve B katsayılarının farklı BO 5 , F/M ve UAKM deerlerindekisayısal ifadeleri bulunmu ve aralarında Ln(B) = 4.097*ln(A) + (0.281) gibi bir baıntının var olduu
Sonuç olarak; arıtma tesislerinin tasarımında kullanılacak debi, kirlik yükü ve dier tasarım parametrelerinin
seçiminde oldukça titiz çalımaların yapı lması ve gereinden fazla bırakılan emniyet paylarından da mümkünThe wastewater flow rates and BOD5
loading to be used for the design of the wastewater treatment plantsare generally estimated within proper tolerance ranges without sufficient investigation. In addition the values of
some design parameters which differ depending on the type of the plant are selected considering the limit
values given in literature. In this study; the effects of the flow rates and BOD 5 loading estimated wide toleranceranges and design parameters on the investment and energy costs of the aeration tanks were investigated.
The studies revealed that the variations in BOD
5, flow rate, F/M ratio and MLVSS effect significantly the
investigation cost and there is a relation between the parameters which can be expressed as COST = (BOD
5 A B. The values of A and B were calculated for different BOD 5 , F/M and MLVSS amounts and relation betweenthem were determined as Ln(B) = 4.097*ln(A) + (0.281). In addition, equipment coasts of diffused aeration
systems are higher 30% ratio related on pollution load activities. Furthermore; it was observed that diffused
aeration systems energy coasts are 10% cheaper than mechanical aeration systems. It has been concluded that,
the determination of the flow rates, pollution loading and other design parameters for the treatment plant design
should be made sensitively and avoiding from wide tolerance ranges for these parameters will reduce significantly investment and energy costs of the treatment plant.ANAHTAR KELMELER / KEY WORDS
Havalandırma havuzu maliyeti, Debi-maliyet ilikisi, BO 5 -maliyet ilikisi, BO5 kirlilik yüküAeration tank cost, Flow rate-cost relation, BOD
5 -cost relation, BOD 5 loadingquotesdbs_dbs27.pdfusesText_33[PDF] BOI G-1-09
[PDF] BOI N° 131 du 27 DECEMBRE 2007 [BOI 4A-9-07 ] - BOFiP - Anciens Et Réunions
[PDF] BOI N° 28 du 9 FEVRIER 2000 [BOI 5F-7-00] - BOFiP-Impôts - France
[PDF] BOI N° 5 du 13 JANVIER 2006 [BOI 3A-3-06] - BOFiP-Impôts
[PDF] BOI N° 60 du 30 MARS 2004 [BOI 5D-2-04 ] - BOFiP-Impôts - France
[PDF] BOI N° 9 du 19 JANVIER 2007 [BOI 7S-1-07] - BOFiP-Impôts - Anciens Et Réunions
[PDF] BOI N° 94 du 21 juin 1985 [BOI 13D-3-85 ] - BOFiP-Impôts
[PDF] BOI-PAT-ISF-40-60-20130614 - France
[PDF] boi-rfpi-decla-30
[PDF] Boileau en Hollande - Poésie
[PDF] Boiler and Pressure Vessels Act
[PDF] Boiler B 10 / B 14
[PDF] Boilerplate considered harmful
[PDF] Boire - Manger - Bouger - Maison de la Nutrition