[PDF] Digital Panel Meters Autoranging Frequency Meter Type DI3-72 F1K





Previous PDF Next PDF



Panel Voltmeter - Ammeter - Frequency meter Direct or alternative

60Hz option for 400 Hz. - compatible with wave train



Panel Meters and Controllers Autoranging Frequency Meter Type

Autoranging Frequency Meter. Type DI3-72 F1K. Type Selection. Power supply. A: 24 VAC -15 -15% +10%



TRMS panel Voltmeter Ammeter

http://www.loreme.fr/fichtech/IPL36l_eng.pdf





Untitled

INPUT: AC 3PH 200-230V 50/60 Hz 0.9A. Identifying the Parts. Chapter 1 The frequency meter displays 0 to 60Hz at 0 to 3V. 10V X n45 setting. 1.00.



2558A AC Voltage Current Standard

Mode. : Internal / External / FREQUENCY METER. Internal : 50 / 60 / 400 Hz. VAR (40 to 1000 Hz 0.001 Hz resolution). External : EXT1 / EXT2. (Use the terminals 



crompton instruments - analogue meters for marine applications

• Burden frequency meter - reed type - 0.7 … 1.2 VA at nominal voltage 110-230 4) Specify frequency: 50/60 Hz. 3-phase 4-wire balanced or. 3-phase 4-wire ...



SPECIFICATION GUIDE ELECTRIC MOTORS

1 Connection to Different Frequencies. Three-phase motors wound for 50 Hz can also be connected to a 60 Hz network a ) By connecting a 50 Hz motor



crompton-instruments.com

60 Hz centre frequency. -0.15 accuracy. 55-65 Hz. •016-41S*-PNAN-AN. 400 Hz Class 2.5 frequency meter 0.5% of mid frequency. Scaling. To BS89



DIN panel meters – short scale

Interchangeable slide-in dials are used on the. E242 E243



Panel Meters and Controllers Autoranging Frequency Meter Type

3-dgt µP-based frequency indicator. • 1.0 to 999 Hz Autoranging Frequency Meter. Type DI3-72 F1K. Type Selection ... 50/60 Hz (standard). Options.



Analogue Instruments

Meter uses a 100 microamp 4000 ohm movement driven by an EMC hard frequency Frequency: 50/60Hz. Accuracy: Moving iron ammeter: Class 1.5. MDI: Class 3.



Untitled

5 to 120 HZ (Frequency setting: in increments of 0.25HZ at 0 to. 60HZ in increments of 0 5HZ at 0 to Connects to frequency meter



Digital Panel Meters Autoranging Frequency Meter Type DI3-72 F1K

3-dgt µP-based frequency indicator. • 1.0 to 999 Hz Autoranging Frequency Meter. Type DI3-72 F1K. Type Selection ... 50/60 Hz (standard). Options.



Untitled

Shows deceleration torque for an uncoupled motor decelerating from 60Hz w/ shortest Frequency (fault output). Meter. Contact Output. (output during run).



din panel meters - tes crompton instruments

50/60 Hz (Single frequencies 25 Hz - 1 kHz on request). PRODUCT CODES Meter uses a 100 microamps 4000 ohm movement driven by an EMC hard frequency.



crompton instruments - analogue meters for marine applications

Integrated selector switch reduces installation time and links the meter with some VT`s having primary voltage less then 1kV). Frequency. 50/60 Hz.



Untitled

(4) For JUSPEED-F with an operator's panel a frequency meter



Panel Voltmeter - Ammeter - Frequency meter Direct or alternative

The 94000CA is a digital meter for voltage or current measurement frequency range : 0...50...60Hz option for 400 Hz ... 94000-Hz (frequency meter).



crompton instruments - analogue meters for marine applications

Integrated selector switch reduces installation time and links the meter with some VT`s having primary voltage less then 1kV). Frequency. 50/60 Hz.

Specifications are subject to change without notice1•3-dgt µP-based frequency indicator

•1.0 to 999 Hz

•Autoranging capability

•72 x 72 mm

• Degree of protection (front): IP 50 (IP 65 on request)Product Description Model

Range code

Measurement

Power supply

Setpoints

Options

Ordering Key

DI3-72F1KAD0XX

3-dgt µP-based frequency

meter with autoranging capa- bility. The housing is for panelmounting and ensures a degree of protection (front) of

IP 50 (IP 65 on request).

Panel Meters and Controllers

Autoranging Frequency Meter

Type DI3-72 F1K

Type SelectionPower supply

A:

24 VAC, -15% +10%,

50/60 Hz

1)

B:48 VAC, -15% +10%,

50/60 Hz

1)

C:115 VAC, -15% +10%,

50/60 Hz

1)

D:230 VAC, -15% +10%,

50/60 Hz (standard)

Options

XX:

None (standard)

EX:Degree of protection

IP 65

Rated input500 VAC, 1 to 1000 Hz,

autorangingOverload protection

Continuous 1.2 x rated input

For 1 s 2 x rated input

Accuracy

Temperature drift± 100 ppm/ºC

Display7-segment LED, h 14.2 mm,

3 digits

Sampling rate1 time/s

Indication

Max. 999

Min. 0.00

Over range EEEInput voltage9 to 500 VAC

Input impedance500 kΩ

Input Specifications

1)

Power supply on request

AC supply230 VAC, -15% +10%,

50/60 Hz (standard)

24 VAC, 48 VAC, 115 VAC,

-15% +10%, 50/60 Hz (on request)

Power consumption3.2 VA

Supply Specifications

Operating temperature0 to 50°C (32 to 122°F) (R.H. < 90% non-condensing) Storage temperature-10 to 60°C (14 to 140°F) (R.H. < 90% non-condensing)

Insulation reference voltage 300 Vrmsto ground

Dielectric strength4000 Vrmsfor 1 minute

Noise rejection

CMRR 100 dB, 40 to 60 Hz

EMCIEC 60801-2, IEC 60801-3,

IEC 60801-4 (level 2),EN 50 081-1, EN 50 082-1

Safety standardsEN 61010-1, IEC 61010-1,

VDE 0411

ConnectorScrew-type

Housing

Dimensions 72 x 72 x 75 mm

Material ABS,

self-extinguishing: UL 94 V-0 Degree of protectionFront: IP 50 (IP 65 on request)

Weight approx.

ApprovalsCE, CSA

General Specifications

2Specifications are subject to change without notice

DI3-72 F1K

66.5 x 66.5

68 x 68

Dimensions (mm)

1 2345678

INNCIN

AIN

V/HzPower supply

IN + 60 mV

Wiring Diagram

Hz

Front Panel Description

1. Display

3-dgt (maximum read-out 999).

Alphanumeric indication by means of 7-segment display for: - Displaying of the measured value, over-range.1

Range Table

Measurement Dec. point Resolution

position

1.00 to 9.99 Hz 9.99 0.01 Hz

10.0 to 99.9 Hz 99.9 0.1 Hz

100 to 999 Hz 999 1 Hz

(Automatic selection)quotesdbs_dbs4.pdfusesText_7
[PDF] 60 hz frequency tolerance

[PDF] 60 hz to 50 hz

[PDF] 60 minute gentle flow yoga sequence

[PDF] 60 minute gentle yoga sequence

[PDF] 60 minutes australia cast

[PDF] 60 minutes australia coronavirus

[PDF] 60 minutes australia jeffrey epstein

[PDF] 60 minutes australia reporters

[PDF] 60 minutes australia sarah abo

[PDF] 60 minutes australia wet markets

[PDF] 60 minutes cast 1990

[PDF] 60 minutes cast 2000

[PDF] 60 minutes cast 2018

[PDF] 60 minutes cast death

[PDF] 60 minutes cast over the years