Jaugeur ENRAF modèle 854
17 juil. 1992 Le jaugeur ENRAF modèle 854 est utilisé pour le mesurage de la hauteur de liquide contenu dans un récipient-mesure.
Instruction manual Series 854 ATG level gauge
8 sept. 2013 This manual is intended for technicians involved with the commissioning and service of the Honeywell Enraf series 854 Advanced Technology Gauge.
ENRAF SERVO GAUGE 854 ATG
ENRAF SERVO GAUGE 854 ATG. Setting the standard in gauging. Trading Partner: Aliado Comercial: HOUSTON TX - USA + 1 281.469.1423 info@ferrumenergy.com.
Installation guide 854 XTG Level Gauge
The Honeywell Enraf 854 XTG is a servo gauge which measures the liquid level and can also be programmed to measure two additional interface levels. This
République Algérienne Démocratique et Populaire
Jaugeur ENRAF placé sur bac ……………………………. 16. Figure I.13 Le jaugeur de la série ENRAF 854 ATG est un dispositif très performant et précis et utiliser.
Automatisation dune unité de déchargement au centre de stockage
6 avr. 1982 a) La jauge 854. La jauge Enraf 854 ATG est une jauge servo-commandée qui permet de mesurer le niveau de liquide et peut également être ...
Servo Gauge 854 ATG
As tank gauging has evolved the series 854 ATG servo level I i.s. Output for Tank Side Indicator (TSI) and Enraf Bi Phase Mark (BPM) protocol.
Installation guide 854 Advanced Technology Gauge
The Honeywell Enraf 854 ATG is a servo gauge which measures the liquid level and can also be programmed to measure two additional interface levels. This
Système de téléjaugeage Rosemount™
Utilisez l'émulation de jauge pour remplacer La jauge radar/le transmetteur se compose d'une tête de ... Enraf® BPM Varec
portant agrément hors Code des
D six jaugeurs ENRAF type 854 ; ! six sondes de température multiPoint VITO ENRAF ;. ) six sondes atarmes de niveau très haut ALARMSCOUT ;.
ENRAF SERVO GAUGE 854 ATG
Setting the standard in gauging.
Trading Partner:
Aliado Comercial:
HOUSTON, TX - USA + 1 281.469.1423
info@ferrumenergy.com ferrumenergy .comNotes:
HART® is a registered trademark of the HART
Communications Foundation.
Foundation™ Fieldbus is a trademark of the
Fieldbus Foundation.
1Under reference conditions
2Mi nimum product density between layers:
100 kg/m3 (6.25 lb/ft3)*
3 (o ptional) with a density displacer and calibrated for density measurement 4With VITO temperature probe or spot (Pt100)
5Se rvo ATG can be used in safety rated loops
using alarm relays and/or analog output.Please refer to Safety Manual.*
6Di stances of more than 10 km possible
depending on amount of eld instruments and cabling topology. 7In e xtreme environments the accuracy
could be affected depending on the thermal expansion coefcient of the wetted parts.Technical Specifications
Data Communication
Honeywell Bi-phase mark (Pos 2 = E and I)
Baud rate 1200 / 2400 bps
Isolation voltage > 1,500 V
Lightning protection Full galvanic separation via isolating transformers Protocol Standard Honeywell eldbus (Serial, ASCII, GPU protocol)Common mode rejection > 150 dB
Cabling Two wires, twisted pair, Rmax = 200 / line, Cmax = 1 μF;Cable length: 10 km (6 mi) or more
*6RS-232C GPU protocol (Pos 2 = R)
Baud rate 1200 / 2400 / 4800 / 9600 / 19200 bps
Isolation voltage > 600 V
Lightning protection Opto-isolators
Protocol Serial ASCII GPU protocol
Cabling 3-wire RS-232; max cable length: 15 m (50 ft)RS-485 GPU protocol (Pos 2 = S)
Baud rate 1200 / 2400 / 4800 / 9600 / 19200 bps
Isolation voltage > 600 V
Lightning protection Opto-isolators
Protocol Serial ASCII GPU protocol
Cabling 3-wire EIA-485; max cable length: 1200 m (4000 ft)RS-232C Std. Modbus (Pos 2 = V)
Baud rate 1200 / 2400 / 4800 / 9600 / 19200 bps
Isolation voltage > 600 V
Lightning protection Opto-isolators
Protocol Std Modbus (refer to protocol manual for details) Cabling 3-wire RS-232; max cable length: 15 m (50 ft)RS-485 Std. Modbus (Pos 2 = W)
Baud rate 1200 / 2400 / 4800 / 9600 / 19200 bps
Isolation voltage > 600 V
Lightning protection Opto-isolators
Protocol Std Modbus (refer to protocol manual for details) Cabling 3-wire EIA-485; max cable length: 1200 m (4000 ft)Foundation
Fieldbus (Pos 2 = O)
Baud rate 31.25 kbps
Isolation voltage > 1500 V
Lightning protection Opto-isolators
Protocol FF (refer to protocol manual for details)Cabling Refer FF specications
Communication with TSI (Pos 2 = I)
Cabling 2-wire, intrinsically safe (Rmax = 5 (loop) / line, Cmax = 1.27μF)Communication with Portable Honeywell Terminal
Protocol Infra-red, serial
Options
Alarm relay outputs 2 x SPDT, galvanically isolated, Vmax = 50 Vac or 30 Vdc, Imax = 3 A; Pos 16 = W Density measurement With density PROMS (Pos 15 = D) and density displacer (Pos 22 = E or F) Analog level output 4 - 20 mA (accuracy ± 0.1% full scale); Pos 4 = V, W, X or YTemperature input and HART devices Spot RTD; 3 wire; Pos 4 = B, U or Y; VITO probes for average temperature and/or
water measurement, HART devices; Pos 4 = C, J, W, X or Y Cable entries Adapters available to t other sizes cable glandsContinued....
Technical Specifications ()
Measuring Specications
Measuring range
Standard 27 m (88 ft) Pos 12 = 2, A, B, C or D
Extended 37 m (121 ft) Pos 12 = 3, K, L, M or N;
35 m (115 ft) (with measuring wire up to 150 m (492 ft)) Pos 12 = 9;
For longer ranges, please contact factory
Measuring accuracy level
(27 m / 88 ft): < ± 0.4 mm (± 0.016") *1 ; (37 m / 121 ft): < ± 0.7 mm (± 0.028") *1Measuring accuracy interface
< ± 2 mm (± 0.08") *2Measuring accuracy servo density
< ± 3 kg/m 3 (± 0.19 lb/ft 3Measuring accuracy temperature
< ± 0.1 °C (± 0.18 °F) *1, *4Sensitivity
0.1 mm (± 0.004") *1Repeatability
0.1 mm (± 0.004") *1Mechanical
Flange
See 'Identification Code' Pos 8-10
Dimensions
See Dimensional Drawing"
Weight
Medium pressure version 16 kg (35 lb)
Chemical version 21 kg (46 lb)
High pressure version 26 kg (57 lb)
Cable entries
4 x ¾" NPT threaded (2* I.S. + 2* non-I.S.)
Process
Operating pressure
M and C versions
Up to 6 bar / 0.6 MPa (90 psi); Pos 8
H version
Up to 40 bar / 4 MPa (600 psi) (up to 25 bar / 2.5 MPa in acc. to PED); Pos 8Temperature
Max. process temperature
+200 °C (+392 °F), drum housing has to be kept below +65 °C (+149 °F)*7
Min. process temperature
-200 °C (-328 °F), drum housing has to be kept above -40 °C (-40 °F) *7Process Wetted Materials
Drum compartment
Cast aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3; Pos 8 = M Stainless steel ASTM A351, CF-8M, G-X6 CrNiMo 18 10 (1.4408); Pos 8 = H or CMeasuring drum, drum shaft
Stainless steel (1.4401) EN10088 AISI 316
Measuring wire
See Identication Code"; Pos 12
Magnet cap
Stainless steel (1.4401) EN10088 AISI 316
O-rings
Drum cover Silicone/FEP; others FPN (Viton
); Special O-ring (Perlas ) available for demanding chemical applications (such as Ammonia), part nr. S0854969Enclosure Materials
Servo comp. and cover
All types cast aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3Finish aluminum parts
Conforms to MIL-DTL-5541F
Environmental Safety
Ambient temperature
-40 °C to +65 °C (-40 °F to +149 °F)Storage temperature
-50 °C to +70 °C (-58 °F to +158 °F)Protection class
IP66 / IP67 according to EN 60529 (NEMA 4X)
Safety
Explosion proof
- II 1/ Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb or Ex d [ia Ga] IIB T6Ga/Gb or
Ex de [ia Ga] IIB T6 Ga/Gb; acc. to ATEX KEMA
- Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb or Ex d [ia Ga] IIB T6 Ga/Gb orEx de [ia Ga] IIB T6 Ga/Gb; acc. to IECEx KEMA
- II 1/ Ex de [ia Ga] IIB T6 Ga/Gb, acc. to Kosha certicate; - Class I, Division 1, Group C & D; acc. to FM - Class I, Group C & D acc. to CSA certicate - Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb or Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb; acc. to INMETRO TÜVConsult factory for other approvals and updates
quotesdbs_dbs3.pdfusesText_6[PDF] java books pdf
[PDF] java the complete reference 9th edition pdf
[PDF] java tp corrigé
[PDF] java tutorial pdf francais
[PDF] java tutorial points pdf
[PDF] javascript cours et exercices corrigés pdf
[PDF] javascript formulaire pdf
[PDF] jax physique 2013 results
[PDF] jax physique 2014 results
[PDF] jcc 2016 liste des film
[PDF] jcr 2017
[PDF] jcr impact factor 2016
[PDF] je communique en français 7éme année corrigé
[PDF] je communique en français 7éme année de l'enseignement de base