Standard high efficiency EU4-pleated air filters housed in a dedicated EU4 ( standard) or EU5 air filters with or EC backward-curved centrifugal motor fan
Previous PDF | Next PDF |
[PDF] A Fläkt Woods Company Ventilateurs centrifuges industriels
Comment lire une désignation d'un ventilateur centrifuge ? Centripal EU 4 L D 560 RD 45 Adx Std
[PDF] Industrial Centrifugal Fans: Centripal EU - Condair
The Centripal EU range has been designed by Fläkt Solyvent Ventec to become the new European CENTRIPAL EU 4 - MD/LD/KD/HD - 2, 4 and 6 poles ∆
[PDF] Uniflair Air Cooled Room Cooling - Downloadschneider-electriccom
Standard high efficiency EU4-pleated air filters housed in a dedicated EU4 ( standard) or EU5 air filters with or EC backward-curved centrifugal motor fan
[PDF] Uniflair Air Cooled Room Cooling LDAV - Downloadschneider
Standard high efficiency EU4-pleated air filters housed in a dedicated EU4 ( standard) or EU5 air filters with or EC backward-curved centrifugal motor fan
[PDF] Centrifugal fans CAL - Novenco Building
Centrifugal fans type CAL Installation and maintenance 1 The CAL centrifugal fans must be in- stalled according to EU 4/2014: ECO design requirements
[PDF] CENTRIFUGAL FANS AND IN-LINE DUCT EXTRACTORS - Sodeca
SODECA has concentrated its activity on the production of industrial fans, ventilation systems and extractors for the removal of smoke in case of fire since 1983,
[PDF] Ventilation Guide wwwxpelaircom
Long life, energy saving dMEV centrifugal fans developing centrifugal fans, Xpelair can offer a ventilation Fresh air intake and dwelling extract filters (EU4)
[PDF] INDUSTRIAL AND BUILDING VENTILATION - Elicent
9 jui 2018 · HT ATEX - Backward curved blades centrifugal fans for dusty air (standard version with filter in polyester with efficiency 90 1 , class EU4)
[PDF] Centro de Medicina del Deporte - Mexique Et Amérique Centrale
[PDF] Centro de Yoza - Scoot
[PDF] centro di documentazione e laboratorio didattico
[PDF] Centro Interdipartimentale di Studi su Descartes e il Seicento
[PDF] Centro Italo-Tedesco per l`Eccellenza Europea Villa Vigoni
[PDF] Centro Nacional de Capacitación en Agua - Anciens Et Réunions
[PDF] Centro Operativo Risanamento Ambiente Lavoro
[PDF] centro raccolta differenziata - Anciens Et Réunions
[PDF] centro tessile - Golden Lady Company S.p.A.
[PDF] centro zaragoza - Insurance Association of Cyprus - Achats
[PDF] Centrobenessere - Bibione Palace Suite Hotel
[PDF] CENTROCAST TABLE - Conception
[PDF] Centronic SensorControl SC43 - Becker
[PDF] Centronic TimeControl TC42 - France
UniflairAir Cooled Room Cooling
IDAV IUAV IXAV
UniflairRoom CoolingIDAV/IUAV/IXAV
precisionair conditionersfor IT and mission criticalapplications.Cooling capacity: 50 ÷150 kW
Direct expansion air-cooled
Variable Speed Drive scroll compressors
Downflow, Upflowand Underfloor
configurationsRefrigerantR410A
EC fans
UniflairDirect Expansion Air Cooled Room
Cooling with Variable Speed Drive
compressors50 150 Kw
Electrical panel
Three-phase power supply 400 V/3 Ph+N/50 Hz for
all the units with a single or a double power supply Low voltage secondary circuit 24 Vac with isolation transformerMetal isolating screen for protection from live
componentsGeneral isolator with mechanical interlock
Thermo magnetic circuit-breakers for protection
Terminal board for no-voltage signal and control
contactsAir filters
Standard high efficiency EU4-pleated air filters housed in a dedicated plenum box (IDAV, IXAV models)Dirty filter differential pressure switch
Low airflow differential pressure switch
Brushless VSD scroll compressor
Discharge temperature control
High energy efficiency at partial load
Low starting current
No sliding contacts
System Architecture: standard features
New microprocessor controller
7-inch, touch-screen LCD display interface
Integrated management of the EEV and
refrigerating circuit parametersIntegrated Unloading logic on VSD units
Full management of the condenser status including
single fan statusGrouping logic integrated
RS485 and TCP/IP card bus integrated targeting
the main communication protocolsNative communication with StruxureWare system,
NetBotzremote sensors
USB and Service port integrated in the display
interfaceElectronically Commuted Radical fans
High-tech compound material impellers with
optimized flow controlHigh efficiency Green Tech EC motors
Low power consumption
High part-load efficiency
Fan speed regulation by Modbus signal
Regulate airflow based on actual thermal load
Easy serviceability with quick removal kit
Underfloor fan module (IXAV units)
Cooling coil
Heat exchanger coils designed for high sensible
heat ratio (SHR) and reduced pressure dropsMade from copper tubes mechanically expanded
on aluminum finsHydrophilic coil coating
FrameSelf-supporting frame in galvanized steel with
panelsExternal panels coated with RAL9003 epoxy-
polyester paintInternal panels with captive screws
Internally lined with heat and sound-proofing
insulationRefrigeration circuit inspection with unit active
Side panels with coil inspection opening
Mainconfigurableoptions
Power supply
Single power supply
Double power supply with automatic
commutation to provide redundancy and ensure a constant power supplyConstruction options
Downflow units (IDAV): top air return with
bottom or front discharge (without additional floor stands)Upflowunits (IUAV): front or bottom air return
with top dischargeUnderfloor units (IXAV): top air return with
bottom supply with multiple fan module configurationsStandard, cleanable or low conductibility
humidifier (cooling + humidification configuration)Condensate drain pump (cooling only and
cooling + dehumidification configurations)Standard electrical heaters with extended fins,
complete with double safety thermostat and manual resettingEU4 (standard) or EU5 air filters with or
without motorized damperPower phase capacitors (not available for
I*AV1511A models)
Energy meter and CO2emission calculator
Automatic Floor Pressurization System
through Active Floor Control (AFC)Additional accessories
Suction from the top and front discharge
plenums: they can be equipped with soundproofed insulation or with high efficiency air filtersBack and top suction direct free-cooling
plenumFloor stands (200mm height)
Floor stands with motorized damper (500mm
height)Motorized damper
Adjustable baseframe(200 600 mm)
Fire and smoke sensors
Water leak detector
Room air temperature / humidity sensor
Air-cooled remote condensers (OCC)
R410A refrigerant
Vertical or horizontal installation
Low-speed axial fans compliant with ERP2015
Versions with electronically commutated (EC)
motor to reduce the sound pressure level (optional)Fan speed regulator works exclusively via
Modbus commands
Coil protection treatment for aggressive
ambient (optional)Low temperature versions to operate down to -
40°C (optional)
Fan module configurations (only IXAV models)
Fan module with bottom supply
Fan module with rear supply
Fan module with front supply
Fan module with front and side supply
Fan module with fully open supply
Technical data IDAV / IUAV
1: Gross cooling capacities; fans must be deducted to obtain net cooling data.
2: Data refer to nominal conditions: Room at 35 °C 30% RH, condensing temperature 45 °C.
IDAV models1511A1922A2022A2422A2922A3822A
Fan typeEC backward-curved centrifugal motor fan
Power supplyV/ph/Hz400 / 3ph / 50 Hz
Fansnr.222223
Air flow m3/h168001680017000200002600027000
Gross total cooling capacity1,2kW65.676.280.0108.8124.0156.7 Gross sensible cooling capacity1,2kW 65.676.280.0108.8124.0156.7 Fan power consumption1,2kW2.412.412.023.034.184.28 Compressor Power ConsumptionkW12.713.913.820.321.631.4IUAV models1511A1922A2022A2422A2922A3822A
Fan typeEC backward-curved centrifugal motor fan
Power supplyV/ph/Hz400 / 3ph / 50 Hz
Fansnr.222223
Air flow m3/h168001680017000200002600027000
Gross total cooling capacity1,2kW65.676.280.0108.8124.0156.7 Gross sensible cooling capacity1,2kW 65.676.280.0108.8124.0156.7 Fan power consumption1,2kW2.412.412.023.034.184.28 Compressor Power ConsumptionkW12.713.913.820.321.631.4Dimensions
IDAV / IUAV models1511A1922A2022A2422A2922A3822A
Height (downflow
units)mm215021502150215021502150Height (upflow
units)mm195019501950195019501950Lengthmm177717772082208226502650
Depthmm900900900900900900
IXAV models2322A2622A4022A
Fan typeEC backward-curved centrifugal motor fan
Power supplyV/ph/Hz400 / 3ph / 50 Hz
Fansnr.223
Air flow m3/h188002340030000
Gross total cooling capacity1,2kW107.0121.8166.8
Gross sensible cooling capacity1,2kW 107.0121.8166.8Fan power consumption1,2kW2.643.694.44
Compressor Power ConsumptionkW20.421.731.3
Dimensions
IXAV models2322A2622A4022A
Height (without fan module)mm215021502150
Fan module heightmm565565565
Lengthmm177720822650
Depthmm900900900
Technical data IXAV
1: Gross cooling capacities; fans must be deducted to obtain net cooling data
2: Data refer to nominal conditions: Room at 35 °C 30% RH, condensing temperature 45 °C.
December2019
se.com/cooling© 2019 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
quotesdbs_dbs2.pdfusesText_4