Standard high efficiency EU4-pleated air filters housed in a dedicated EU4 ( standard) or EU5 air filters with or EC backward-curved centrifugal motor fan
Previous PDF | Next PDF |
[PDF] A Fläkt Woods Company Ventilateurs centrifuges industriels
Comment lire une désignation d'un ventilateur centrifuge ? Centripal EU 4 L D 560 RD 45 Adx Std
[PDF] Industrial Centrifugal Fans: Centripal EU - Condair
The Centripal EU range has been designed by Fläkt Solyvent Ventec to become the new European CENTRIPAL EU 4 - MD/LD/KD/HD - 2, 4 and 6 poles ∆
[PDF] Uniflair Air Cooled Room Cooling - Downloadschneider-electriccom
Standard high efficiency EU4-pleated air filters housed in a dedicated EU4 ( standard) or EU5 air filters with or EC backward-curved centrifugal motor fan
[PDF] Uniflair Air Cooled Room Cooling LDAV - Downloadschneider
Standard high efficiency EU4-pleated air filters housed in a dedicated EU4 ( standard) or EU5 air filters with or EC backward-curved centrifugal motor fan
[PDF] Centrifugal fans CAL - Novenco Building
Centrifugal fans type CAL Installation and maintenance 1 The CAL centrifugal fans must be in- stalled according to EU 4/2014: ECO design requirements
[PDF] CENTRIFUGAL FANS AND IN-LINE DUCT EXTRACTORS - Sodeca
SODECA has concentrated its activity on the production of industrial fans, ventilation systems and extractors for the removal of smoke in case of fire since 1983,
[PDF] Ventilation Guide wwwxpelaircom
Long life, energy saving dMEV centrifugal fans developing centrifugal fans, Xpelair can offer a ventilation Fresh air intake and dwelling extract filters (EU4)
[PDF] INDUSTRIAL AND BUILDING VENTILATION - Elicent
9 jui 2018 · HT ATEX - Backward curved blades centrifugal fans for dusty air (standard version with filter in polyester with efficiency 90 1 , class EU4)
[PDF] Centro de Medicina del Deporte - Mexique Et Amérique Centrale
[PDF] Centro de Yoza - Scoot
[PDF] centro di documentazione e laboratorio didattico
[PDF] Centro Interdipartimentale di Studi su Descartes e il Seicento
[PDF] Centro Italo-Tedesco per l`Eccellenza Europea Villa Vigoni
[PDF] Centro Nacional de Capacitación en Agua - Anciens Et Réunions
[PDF] Centro Operativo Risanamento Ambiente Lavoro
[PDF] centro raccolta differenziata - Anciens Et Réunions
[PDF] centro tessile - Golden Lady Company S.p.A.
[PDF] centro zaragoza - Insurance Association of Cyprus - Achats
[PDF] Centrobenessere - Bibione Palace Suite Hotel
[PDF] CENTROCAST TABLE - Conception
[PDF] Centronic SensorControl SC43 - Becker
[PDF] Centronic TimeControl TC42 - France
UniflairAir Cooled Room Cooling
LDAVUniflairAir CooledRoom CoolingLDAV
precisionair conditionersfor IT and mission criticalapplications.Cooling capacity: 60 ÷140 kW
Air-cooled
Fixed speed scroll compressors
Downflowconfiguration
RefrigerantR410A
EC fans
UniflairDirect Expansion Air Cooled with Fixed
Speed scroll compressors
60 140 kW
Electrical panel
Three-phase power supply 400 V/3 Ph+N/50 Hz for
all the units with a single or a double power supply Low voltage secondary circuit 24 Vacwith isolation transformerMetal isolating screen for protection from live
componentsGeneral isolator with mechanical interlock
Thermo magnetic circuit-breakers for protection
Terminal board for no-voltage signal and control
contactsAir filters
Standard high efficiency EU4-pleated air filters housed in a dedicated plenum boxDirty filter differential pressure switch
Low airflow differential pressure switch
Fixed speed scroll compressor
High energy efficiency in full load
conditionsExtended operating conditions
Equipped with Intermediate Discharge
Valves (IDVs)
System Architecture: standard features
New microprocessor controller
7-inch, touch-screen LCD display interface
Integrated management of the EEV and
refrigerating circuit parametersFull management of the condenser status including
single fan statusGrouping logic integrated
RS485 and TCP/IP card bus integrated targeting
the main communication protocolsNative communication with StruxureWare system,
NetBotzremote sensors
USB and Service port integrated in the display
interfaceElectronically Commuted Radical fans
High-tech compound material impellers with
optimized flow controlHigh efficiency Green Tech EC motors
Low power consumption
High part-load efficiency
Fan speed regulation by Modbus signal
Regulate airflow based on actual thermal load
Easy serviceability with quick removal kit
Cooling coil
Heat exchanger coils designed for high sensible
heat ratio (SHR) and reduced pressure dropsMade from copper tubes mechanically expanded
on aluminum finsHydrophilic coil coating
FrameSelf-supporting frame in galvanized steel with
panelsExternal panels coated with RAL9003 epoxy-
polyester paintInternal panels with captive screws
Internally lined with heat and sound-proofing
insulationRefrigeration circuit inspection with unit active
Side panels with coil inspection opening
Mainconfigurableoptions
Power supply
Single power supply
Double power supply with automatic
commutation to provide redundancy and ensure a constant power supplyConstruction options
Top air return with bottom or front discharge
for downflow units (without additional floor stands)Standard, cleanable or low conductibility
humidifier (cooling + humidification configuration)Condensate drain pump (cooling only and
cooling + dehumidification configurations)Standard electrical heaters with extended fins,
complete with double safety thermostat and manual resettingEU4 (standard) or EU5 air filters with or
without motorized damperPower phase capacitors
Energy meter and CO2emission calculator
Automatic Floor Pressurization System
through Active Floor Control (AFC)Air-cooled remote condensers (OCC)
R410A refrigerant
Vertical or horizontal installation
Low-speed axial fans compliant with ERP2015
Versions with electronically commutated (EC)
motor to reduce the sound pressure level (optional)Fan speed regulator works exclusively via
Modbus commands
Coil protection treatment for aggressive
ambient (optional)Low temperature versions to operate down to -
40°C (optional)
Air-cooled remote condensers (OCC)
R410A refrigerant
Vertical or horizontal installation
Low-speed axial fans compliant with ERP2015
Versions with electronically commutated (EC)
motor to reduce the sound pressure level (optional)Fan speed regulator works exclusively via
Modbus commands
Coil protection treatment for aggressive
ambient (optional)Low temperature versions to operate down to -
40°C (optional)
Technical data LDAV
1: Gross cooling capacities; fans must be deducted to obtain net cooling data.
2: Data refer to nominal conditions: Room at 35 °C 30% RH, condensing temperature 45 °C.
LDAV models2422A2522A2722A3822A
Fan typeEC backward-curved centrifugal motor fan
Power supplyV/ph/Hz400 / 3ph / 50 Hz
Fansnr.2223
Air flow m3/h20000243002600027000
Gross total cooling capacity1,2kW97.5106.2115.8156.1 Gross sensible cooling capacity1,2kW 97.5106.2115.8156.1Fan power consumption1,2kW3.003.484.154.24
Compressor Power ConsumptionkW16.716.318.929.9
Dimensions
LDAV models2422A2522A2722A3822A
Heightmm2150215021502150
Lengthmm2082265026502650
Depthmm900900900900
December2019