Air Conditioning Sizing Chart - A Class
Room Class. Model. Capacity. A. B. C. D. Maximum Floor Area (m2). Ciara™ (DXK05ZTLA-WF). 1.5kW. Cooling. 15. 12. 10. 7. Heating. 19. 16. 13. 10. Avanti PLUS® (
SAFETY CONSIDERATIONS AND CHARGE SIZE GUIDANCE
the room volume calculation still applies. A practical example of a Location factory sealed single package air conditioning systems or heat pumps with a ...
Air Conditioner Sizing Worksheet
Step 1: Calculate the room area to pick the right sized AC unit. Measure the room and use the forms below to calculate the area. Square and Rectangular Rooms.
Room Size Chart
Air Circulation. High l/s. 149. 149. 150. 165. 176. 194. 305. 305. Compressor Type. Rotary. Rotary. Rotary. Rotary. Rotary. Rotary. Scroll. Rotary. Height mm.
Consumer Guide in Buying Room Air Conditioner ENERGY GUIDE
Sizing of Air Conditioner: Rough Estimate**. Local Calculation: Rough Estimate Method. Cooling Capacity= Size of Room (in sq. meter) x 500. Note: Use the next
Safety considerations and charge size guidance when using low
the room volume calculation still applies. A practical example of a location factory sealed single package air conditioning systems or heat pumps with a ...
HVAC Right-Sizing Part 1: Calculating Loads
28 apr 2011 What is HVAC supposed to do? • Keep the occupants of a home more comfortable by. – Adjusting internal temperatures. – Mixing air in rooms. – ...
Safety considerations and charge size guidance when using low
the room volume calculation still applies. A practical example of a location factory sealed single package air conditioning systems or heat pumps with a ...
ARC Technical Resources - Maximum refrigerant charge
Any room split
Non-dwelling Load Calculations
(5) The larger of the air-conditioning load or the space-heating load. 220.33 Optional Calculation — Two Dwelling Units. Where two dwelling units are
Air Conditioning Sizing Chart - A Class
Products are to be installed by a licensed and qualified person only. Selection Chart for Cooling and Heating. Room Class. Model. Capacity. A. B.
Strategy Guideline: Accurate Heating and Cooling Load Calculations
calculating peak heating and cooling loads as the first step of HVAC system to deliver conditioned air to the rooms of the house
Design Guide for Heating Ventilating
https://www.usbr.gov/tsc/techreferences/mands/mands-pdfs/HVACManl.pdf
Cooling Load Calculations and Principles R1.pdf
space air temperature. Space Heat Extraction Rate - the rate at which heat is removed from the conditioned space and is equal to the space cooling load if
HVAC Rule of Thumb Calculator
The floor input is only used to calculate the roof area which is used in the heating load calculations. Sample Office Building. Space. Area (ft2). HVAC Area (
Room Size Chart
Watts. -. -. -. 500-5300. 900-6700. 900-9100. 900-10600. 2200-11000. BTU/h. -. -. -. 1700-18100. 3100-22900. 3100-31000. 3100-36200. 7500-37500.
HOURLY ANALYSIS PROGRAM QUICK REFERENCE GUIDE
items program reports and program calculation procedures. ABOUT HAP buildings in order to determine required sizes for HVAC system components.
A/C Cooling Load calculation and measurement
(air conditioner) from the indoor space to outdoors. The actual electrical power used to operate the appliance is considerably less than the cooling power
HVAC – How to Size and Design Ducts
the plenum and into the conditioned space through supply registers. Calculate the friction head loss (in-H20) from moving 20000 cfm of air through 200.
Properly Sized Room Air Conditioners
Using the calculated area in square meters and the given chart determine the correct cooling capacity. Cooling capacity is measured in kilojoules per hour. (kJ
TypeINVERTER
Model No.Indoor Unit ASTA07JCC ASTA09JCC ASTA12JCC ASTA09LCC ASTA12LCC ASTA18LCC ASTA24LCC ASTA30LCC Outdoor Unit AOTR07JCC AOTR09JCC AOTR12JCC AOTR09LCC AOTR12LCC AOTR18LCC AOTR24LCC AOTR30LCT Reverse Cycle System No No No Yes Yes Yes Yes Yes Cooling CapacityWatts 2100 2600 3500 2600 3500 5200 7400 8000 BTU/h 7200 8900 11900 8900 11900 17700 25300 27300 RangeWatts 500-2800 500-3300 900-4000 500-3600 900-4300 900-5700 900-8000 2900-9000 BTU/h 1700-9600 1700-11300 3100-13700 1700-12300 3100-14700 3100-19400 3100-27300 9900-30700 Heating CapacityWatts - - - 3600 4800 6250 8500 9000BTU/h - - - 12300 16400 21300 29000 30700
RangeWatts - - - 500-5300 900-6700 900-9100 900-10600 2200-11000 BTU/h - - - 1700-18100 3100-22900 3100-31000 3100-36200 7500-37500 Power Supply Volts 240 240 240 240 240 240 240 240 Phase-Frequency Ph - Hz 1-50 1-50 1-50 1-50 1-50 1-50 1-50 1-50 Power Supply Attachment Indoor Indoor Indoor Indoor Indoor Indoor Outdoor OutdoorPlug Size (If Applicable) Amps 10 amp plug 10 amp plug 10 amp plug 10 amp plug 15 amp plug 15 amp plug NA NA
Cooling Amps 2.7 3.4 4.9 3 4.1 7.3 10.4 11.7
Running Current Range Amps TBA TBA TBA Max 6 Max 7 Max 9 Max 12 Max 17Heating Amps - - - 3.9 5.4 7.4 10.2 11.6
Range Amps - - - Max 8.5 Max 10 Max 13.5 Max 17.5 Max 19Cooling Watts 570 740 1110 655 920 1720 2460 2660
InputRange Watts TBA TBA TBA 250-1380 250-1610 90-2000 110-2620 580-3600Heating Watts - - - 845 1240 1730 2420 2640
Range Watts - - - 250-1960 250-2300 90-2660 110-3680 500-4300 Moisture Removal l/hr 1.0 1.3 1.8 1.3 1.8 2.8 3 3.4 E.E.R. Cooling 3.68 3.51 3.15 3.963 3.801 3.022 3.011 2.989C.O.P. Heating - - - 4.261 3.869 3.61 3.516 3.385
Star RatingCooling
Heating - - -?????? ?????? ????? ????? ??????
Fan Speeds 4 4 4 4 4 4 4 4
Air Circulation High l/s 149 149 150 165 176 194 305 305 Compressor Type Rotary Rotary Rotary Rotary Rotary Rotary Scroll RotaryHeight mm 257 257 275 275 275 275 320 320
I.U.Width mm 808 808 790 790 790 790 998 998
Depth mm 187 187 215 215 215 215 228 228
Dimensions Net Weight kg 8 8 8.5 9 9 9 14 14
and Weights Height mm 540 540 540 540 540 578 578 830O.U.Width mm 660 660 790 660 790 790 790 900
Depth mm 290 290 290 290 290 300 315 330
Net Weight kg 30 30 36 32 37 40 44 62
I.U. Sound Pressure Level dBA@1mtr 38 38 38 41 42 42 47 47 O.U. Sound Pressure Level dBA@1mtr 48 48 49 48 49 50 52 53 O.U. Sound Power Level dBA 65 65 67 65 67 68 68 69 Refrigerant Type R410A R410A R410A R410A R410A R410A R410A R410A Connection Pipe SizesGas mm 9.52 9.52 9.52 9.52 9.52 12.7 15.88 15.88Liquid mm 6.35 6.35 6.35 6.35 6.35 6.35 6.35 9.52
Pre Charged Length Metre 7.5 7.5 7.5 15 15 15 15 20Minimum Pipe Length Metre 3 3 3 3 3 3 3 5
Maximum Pipe Length Metre 15 15 15 20 20 20 30 50
Maximum Pipe Height Metre 10 10 10 15 15 15 20 30
Pipe Connection Methods Flare Flare Flare Flare Flare Flare Flare FlareOutdoor operating Temp.Cooling Degrees C 18 to 43 18 to 43 18 to 43 10 to 43 10 to 43 -10 to 43 -10 to 43 -10 to 43
Heating Degrees C - - - -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24WALL MOUNTED
10002000
Watts (W)
Square Metres (M2)0
10 15 20 25 30 35 40 45 50 55 60 65 70
30004000
5000
6000
7000
8000
Small Window Minimum
Large Window Minimum
10002000
Watts (W)
Square Metres (M2)0
10 15 20 25 30 35 40 45 50 55 60 65 70
30004000
5000
6000
7000
8000
10002000
Watts (W)
Square Metres (M2)0
10 15 20 25 30 35 40 45 50 55 60 65 70
30004000
5000
6000
7000
8000
10002000
Watts (W)
Square Metres (M2)0
10 15 20 25 30 35 40 45 50 55 60 65 70
30004000
5000
6000
7000
8000
CEILING INSULATED WINDOW NOT FACING WEST
CEILING INSULATED WINDOW FACING WEST
CEILING UNINSULATED WINDOW NOT FACING WEST
CEILING UNINSULATED WINDOW FACING WEST
Room SizeChart
Check your
requirementsSmall Window Maximum
Large Window Maximum
bkPlease refer to disclaimers on back cover
For future improvement, specifications
& designs of product are subject to change without notice. Heating and cooling capacities are based onAS/NZS 3823.
Cooling
Indoor Temp: 27°C DB/19°C WB
Outdoor Temp: 35°C DB
Heating
Indoor Temp: 20°C DB
Outdoor Temp: 7°C DB /6°C WB
Note:The appropriate load
will vary according to the region.Use only as a guide.
INVERTER
19FG7654_RETAIL_1.qxd 16/10/06 9:22 AM Page 20
quotesdbs_dbs17.pdfusesText_23[PDF] air conditioner tonnage calculator commercial
[PDF] air conditioner unit tonnage calculator
[PDF] air conditioning calculations rule of thumb
[PDF] air conditioning calculator
[PDF] air corsica
[PDF] air desmos
[PDF] air force acquisition process
[PDF] air force acronym dictionary
[PDF] air force approved acronyms 2019
[PDF] air force commendation medal
[PDF] air force customs and courtesies afi
[PDF] air force customs and courtesies calling the room to attention
[PDF] air force expeditionary service ribbon
[PDF] air force good conduct medal