[PDF] prodimed PLEUROCATH® Seldinger. Pleural drainage using





Previous PDF Next PDF



PRODIMED

Drainage pleural selon la technique de Seldinger. PLEUROCATH® selon Seldinger. Description de la technique. Composition du set. • 1 Aiguille de ponction.



Drainage de la plèvre : les techniques et leurs pièges

les différentes techniques de drainage pleural de la moins invasive (exsufflation manuelle et Mise en place d'un pleurocath. Le cathéter est intro-.



PLEUROCATH®

3 mars 2021 PLEUROCATH® selon Seldinger. Drainage pleural selon la technique de Seldinger. Pour commander : 5 unités. Drain. Référence de commande.



prodimed

PLEUROCATH® Seldinger. Pleural drainage using the Seldinger technique. 5 units/box. Drain. Order. Reference. Internal. Reference. Drain length. Guide wire.



Drainage Thoracique

Quelle Technique? ? Exsufflation manuelle. ? Pleurocath. ? Technique de Seldinger. ? Mini-drain. ? Drainage à mandrin. ? Drainage à mandrin.



3 Le drainage thoracique [Mode de compatibilité]

DRAINS PERCUTANÉS: TECHNIQUE ?Technique mini invasive sur guide pour plus de sécurité et un plus grand ... Pleurocath Seldinger : PU droit



Le drainage thoracique aux urgences dans la prise en charge dun

5 avr. 2019 GESTE EN MÉDECINE D'URGENCE / TECHNIQUES IN EMERGENCY MEDICINE ... petits drains (Pleurocath® Prodimed



PLEUROCATH® SELDINGER

14 févr. 2019 2.2 Dénomination commerciale : PLEUROCATH Seldinger ... Les cathéters Pleurocath® Seldinger comportent : ... 5.1 Sécurité technique :.



Exsufflation dun PRemier épisode de pneumothorax spontané

Vidéothoracoscopie et techniques chirurgicales de type PleurocathR ou drains de faible calibre ... Une nouvelle approche d'une technique ancienne?



Untitled

techniques les moins invasives avant d'avoir si nécessaire



[PDF] Pleurocath® PRODIMED

Cette technique est applicable au lit du malade et permet même le drainage de la plèvre de façon atraumatique même en cas de cloisonnement pleural Elle ne 



[PDF] PLEUROCATH® - PRODIMED

3 mar 2021 · Cette technique est applicable au lit du malade et permet même le drainage de la plèvre de façon atraumatique même en cas de cloisonnement 



[PDF] Drainage de la plèvre : les techniques et leurs pièges - SRLF

Drainage techniques ranging from minimally invasive techniques such as manual exsufflation and small pig-tail catheters placed via the Seldinger techniques 



[PDF] PLEUROCATH® SELDINGER - Exhausmed

14 fév 2019 · Après 2 ou 3 jours d'utilisation il est possible de reculer le Pleurocath de 1 à 3 cm afin de changer la position des orifices d'aspiration b



PLEUROCATH® - PRODIMED - Catalogue PDF Brochure

Consultez l'intégralité du catalogue PLEUROCATH® de la société PRODIMED sur MedicalExpo Tous les catalogues et fiches techniques (PDF) PRODIMED



[PDF] Drainage pleural - HUG

Annule et remplace technique : Drainage thoracique de 2000 Techniques d'assistance : "Pose d'un drain thoracique de Monaldi" "Pose d'un pleurocath"



[PDF] Le drainage thoracique - CH Carcassonne

9 jan 2017 · procédure médicale (post ponction pleurale ou trans-thoracique post pose de VVC ou de Port-à-Cath ) Le pneumothorax traumatique peut être 



[PDF] Drainage pleural - SFAR

Le drainage pleural est un des gestes techniques les plus fréquents dans la pratique quotidienne de réanimation ou en service L'emploi d'un Pleurocath®



[PDF] Drainage thoracique aux urgences

techniques d'évacuation de la cavité pleurale D Pleurocath® Manual aspiration versus chest tube drainage in first episodes of



Le drainage thoracique aux urgences dans la prise en charge dun

5 avr 2019 · GESTE EN MÉDECINE D'URGENCE / TECHNIQUES IN EMERGENCY MEDICINE petits drains (Pleurocath® Prodimed Le Plessis Bouchard

  • Comment poser un Pleurx ?

    Mise en place :
    La mise en place du cathéter peut être faite en ambulatoire, sous anesthésie locale à l'aide d'une échographie ou d'une radiographie. Le cathéter est tunnelisé et fixé par le biais de deux sutures. Les fils de la cicatrice d'insertion (1) peuvent être enlevés après 10 jours.
  • Comment drainer une pleurésie ?

    Le liquide d'une pleurésie peut être difficile à ponctionner parce qu'il est épais, que la plèvre est cloisonnée en multiple logettes, c'est la cas des pleurésies purulentes, des hémothorax (sang et caillots dans la plèvre) un drainage avec un drain de gros calibre est nécessaire.
  • Comment se pratique le drainage pleural ?

    Après le nettoyage et la désinfection de la zone choisie, il faut effectuer une anesthésie locale et mettre en place un champ stérile. Le médecin pratique ensuite au bistouri une incision de 1 à 1,5 cm et dégage en écartant les tissus un passage étroit jusqu'à la plèvre.
  • Le médecin, après une désinfection de la peau et, éventuellement, une légère anesthésie locale à la xylocaïne, introduit, de manière indolore, entre les deux côtes, dans la cavité pleurale contenant le liquide ou l'air, l'aiguille ou le trocart. À l'aide d'une seringue, il recueille le contenu de la plèvre.

PLEUROCATH

Pleural Drainage•

F A B R I Q U

É EN

F R A N C E M A D E IN FR A N C E

Full range

PLEUROCATH

Seldinger

Pleural drainage using the Seldinger technique

5 units/box

Drain Order

ReferenceInternal

Reference

Drain length

Guide wireDilatorNeedle

Fr (mm)PerforationcmDiameter

inch (mm)

Length

cm

External

diameter Fr

Length

cm

Diameter mm (G)

Length (mm)

6 (2.0)3 cm5343.207004541250.037

(0.95)307101.24 mm (18G) 55 mm

8 (2.7)8 cm5344.277003260

40
0.038 (0.97)709 11

1.42 mm (17G)

75 mm10 (3.3)8 cm5344.337003261

1212 (4.0)8 cm5344.407003262

12 (4.0)3 cm5354.40

(1)

7003263

(1) 0.035 (0.89)1.47 mm (17G) 90 mm
(1) A rounded, blunt-ended model provided with a Tuohy needle (with a curved end)

Composition of the kit

• 1 Scalpel • 1 Introducer needle

1 Multi-perforated drain with inte-

grated three-way tap • 1 Straight guide wire

1 6-13 mm conical connector for

aspiration nozzle • 1 10 ml Luer-Lok syringe • 1 Dilator • 1 versilic tube

Emballage pelable

Radio opaque

Pol yéthylène

Polyéthylène Glycol

1 3 3 2 4

Puncture the cavity using the

introducer needle and syringe.

Remove the introducer needle,

leaving the guide wire in place.

Insert the Pleurocath

following the guide wire.Insert the coiled guide wire into the introducer needle.

Use a dilator to increase the

size of the needle site.

The dilator should be inserted

using a slight rotational movement. The dilator is then removed.

Technique description

The syringe will ?ll with air in the case of pneumothorax or ?uid in the case of effusion

PLEUROCATH

Seldinger

Ref 5344.40

PLEUROCATH

, for safe and effective pleural drainage

PLEUROCATH

20 units/box

20 units/box

DrainOrder

ReferenceInternal

Reference

Drain length

Needle

Fr (mm)PerforationcmDiameter mm (G)

Length (mm)

8 (2.7)

10 cm5325.277003253

503.32 mm (10G)

77 mm

10 (3.3)5325.3370032554.00 mm (10G)

77 mm

10 (3.3)5325P33

(2)

70032564.00 mm (10G)

77 mm

DrainOrder

ReferenceInternal

Reference

Drain length

Needle

Fr (mm)PerforationcmDiameter mm (G)

Length (mm)

Neonatal drain6 (2.0)3 cm5323.207003250302.42 mm (13G) 57 mm
Neonatal drain8 (2.7)4 cm5324.277003252403.32 mm (10G) 77 mm
(2) P = Système anti-plicature

Composition of the kit

• 1 Introducer needle

1 Drain multi-perforated over

10 cm (inside a sheath in order

to guarantee asepsis during use, to detect positive or negative pressure and to identify the nature of the ?uid or air collected) • 1 Three-way tap

1 6-13 mm conical connector for

aspiration nozzle

PLEUROCATH

Ref 5325.27

Emballage pelable

Radio opaque

Pol yéthylène

Polyéthylène GlycolEmballage pelable

Radio opaque

Pol yéthylène

Polyéthylène Glycol

Emballage pelable

Radio opaque

Pol yéthylène

Polyéthylène Glycol

PLEUROCATH

, for safe and effective pleural drainage

Peelable packaging

RadiopaquePolyethylene

Polyéthylène Glycol

Guibout PLEUROCATH

PLEUROCATH

SAMU

DrainOrder

ReferenceInternal

Reference

Drain length

Needle

Fr (mm)PerforationcmDiamètre mm (G)

Long (mm)

8 (2.7)10 cm5375.277003264503.32 mm (10G)

77 mm

DrainOrder

ReferenceInternal

Reference

Drain length

Needle

Fr (mm)PerforationcmDiamètre mm (G)

Long (mm)

8 (2.7)4 cm5334.277003259403.32 mm (10G)

77 mm

Composition of the kit

1 Detachable introducer needle with

hollow stylet. The stylet prevents coring during insertion

1 Drain multi-perforated over 10 cm

(inside a sheath in order to guarantee asepsis during use, to detect positive or negative pressure and to identify the nature of the ?uid or air collected) • 1 Three-way tap

1 6-13 mm conical connector for

aspiration nozzle • 1 12 ml Luer-Lok syringe

Composition of the kit

1 Detachable introducer needle with

hollow stylet

1 Drain multi-perforated over 10 cm

(inside a sheath in order to guarantee asepsis during use, to detect positive or negative pressure and to identify the nature of the ?uid or air collected) • 1 Two-way tap

1 6-13 mm conical connector for

aspiration nozzle

Emballage pelable

Radio opaque

Pol yéthylène

Polyéthylène Glycol

Emballage pelable

Radio opaque

Pol yéthylène

Polyéthylène Glycol

PLEUROCATH

SAMUGuibout PLEUROCATH

20 units/box

20 units/box

Pleurocath

range

A pneumothorax is classically drained via the 2

nd or 3 rd intercostal space along the midclavicular line, and liquid effusion via the 6 th or 7 th intercostal space along the midaxillary line. It can sometimes be necessary to choose a different drainage point in the event of local causes (trauma, scarring, etc.) or if the effusion has become partitioned. The medical device used to carry out drainage is also important to falicitate the procedure and ensure its safety.

Our Pleurocath

range allows you to choose the most suitable device for your procedure, ensuring it is carried out smoothly. The Pleurocath can be used with various techniques: Seldinger, "Guibout" (using a syringe to control the procedure) or classic technique.

Kit presentations

The

Pleurocath

is always presented as a kit. All the content of the kit allows you to perform your procedure using the proper materials.

Pleurocath

Seldinger technique

(3)

This technique tends to be used because of its simplicity and safety. It can be performed by the patient's bed and

allows the pleura to be drained automatically, even in the event of partitioned effusion.

It does not require extensive dissection of the intercostal space as the route prepared by the dilator is adjusted to

the diameter of the pleural catheter. This technique reduces the pain felt by the patient when placing the drain,

but also the risk of infection at the opening of the skin and unpleasant sequelae.

Choice of drain calibre and indication

(3)

extensive the pneumothorax is. To drain a haemothorax or in cases of purulent pleurisy, large-calibre drains may be

used.

Pleurocath

drains have calibres ranging from 6 to 12 Fr and can therefore treat all types of pneumothorax, including

?uid effusion that is extensive or of low-to-moderate viscosity.

Matériaux

Pleurocath

is available in: • Polyethylene: Being the most widely used plastic polymer nowadays, it has a simple chemical structure and is chemically inert. This is one of the polymers most widely used in the production of medical devices.• Polyurethane: Polyurethane is one of the most polyvalent polymers. It has higher mechanical qualities than silicone (with greater ?exibility and higher kink resistance).

Expertise

The Pleurocath

range for pleural drainage is a family of products recognised by specialists. Having been in use for several years, it draws on a signi?cant amount of experience.

Pleurocath

stands for ef?ciency and patient safety.

Numerous benefits

Benefits of Pleurocath

(3) Makris D. et Marquette C.-H. Drainage de la plèvre : les techniques et leurs pièges [Pleural drainage: techniques and their pitfalls]. Réanimation [Intensive

Care] (2009) 18 163-169.

6, rue Louis Armand

95130 LE PLESSIS BOUCHARD

Customer service

Tel. : +33 (0)1 44 95 17 00

Fax : +33 (0)1 44 95 14 90

Email : serviceclients@ccdlab.com

www.prodimed.com

Pleurocath lea?et - 02/21 - SAP : 3000392

This document is intented solely for the use of healthcare professionals. Class IIa, sterile medical devices - CE0459 - Manufacturer: PRODIMED Carefully read the instructions. Use before the expiry date indicated on the wrapping. Do not use if the wrapping or primary packaging is damaged. Peelable packaging - Latex-free - Radiopaque - Single-use medical devices. F A B R I Q U

É EN

F R A N C E M A D E IN FR A N C Equotesdbs_dbs35.pdfusesText_40
[PDF] drain pleural en aspiration douce

[PDF] le drapé dans l'art contemporain

[PDF] tous les drapeaux du monde pdf

[PDF] drapeau rouge blanc rouge horizontal

[PDF] les drapeaux du monde entier avec leur nom

[PDF] telecharger drapeaux du monde gratuit

[PDF] drapeau orange blanc vert vertical

[PDF] drapeau rouge blanc vert horizontal

[PDF] drapeau vert blanc rouge vertical

[PDF] drapeau noir jaune vert blanc rouge bleu

[PDF] drapeaux pdf

[PDF] drapeau course moto

[PDF] signification drapeau course automobile

[PDF] drapeau commissaire de piste achat

[PDF] drapeau casm moto cross