Catalogue
???/???/???? Quelles garanties apporte-t-elle… ? Pourquoi choisir ISOVER ? TOITURE PAR. L'EXTÉRIEUR. COMBLES. PERDUS.
FAO Publications catalogue 2017
This online version of the FAO Catalogue 2017 This catalogue gives a general overview of FAO's work over ... is over 253 years old. ©FAO. Rome 2017 ...
Renovation of the block in Madrid in accordance with criteria of
Isover 2017) within the framework of 13th International houses does not exceed 15 kWh/m2 per year (Catalog of Isover products … ). As a result of.
Isover
mineral wool insulation ISOVER is made from the earth's or at the end of the catalogue in the chapter ISOVER. Products on page 23. fire reSiStAnce.
2017 Brochure - Sanofi
While the cure rate for the 300000 children and ado- lescents diagnosed each year with cancer is over 80% in de veloped countries
Catalogue 2017_310717_Final version (2) (db) (JA) (AH) (2)
Catalogue of national health and social care data collections: Version 3.0 Information can be lost documentation is poor
2017-2018 Texas A&M University-San Antonio Catalog - updated
???/???/???? University Catalog. 2017-2018. Accreditations Certifications and Approved Programs. Texas A&M University-San Antonio is accredited by the ...
A337422 ISOVER Thermal Performance Brochure-d2
2 2017 additional guidance for the Republic of Ireland has been issued in respect to timber framed elements for walls
ADN catalogue of questions 2017: General/Transport by dry cargo
ADN catalogue of questions 2017: General/Transport by dry cargo vessels/Transport by tank vessels the cargo tank is over 40 kPa. What should be done?
2017-general-catalog-.pdf
2 PEARL DRUMS 2017 GENERAL CATALOG. WWW.PEARLDRUM. Practice Time is Over It's Time to Get Serious • To elevate the playing field for today's advancing.
THERMAL WALL &
FLOOR SOLUTIONS
Wall & Floor Solutions
for Thermal PerformanceCONTENTS
Introduction ........................................................................ ......................3 Standards and Certication ..............................................................4 Fire Performance ........................................................................ ............5 Building Regulations ........................................................................ .....6Timber Frame External Wall
Masonry Separating Party Wall
Suspended Ground Floors ................................................................14Isover Metac Roll
...........16 Case Study ........................................................................ ......................18THERMAL WALL & FLOOR SOLUTIONS
THERMAL WALLS & FLOORS
ISOVER INSULATION & VARIO®
SYSTEM
Isover o ers one of the safest options for insulating walls & oors for thermal performance, both in NewBuild and Renovation projects.
Isover Metac is a high performance mineral wool insulation slab on a roll".When used in conjunction with our Vario
Airtightness and Moisture Control
System it o ers a market leading solution in terms of thermal, acoustic and safety performance. If also combined with Isover InLiner Board you have the complete mineral wool pitched roof solution. Isover InLiner Board is a super dense, rigid and high performance laminated insulation plasterboard.Metac insulation
MHigh performance thermal insulation
MVapour permeable insulation for maximum protection from moisture and condensation issues MA1 re rating (for Isover mineral wool) highest rating on the marketEN 13501-1
MAvoid slump during installation and life of the systemMFriction ts to aid in eliminating any air gaps
MExcellent Indoor Air Quality Euro ns Gold Comfort MMade from Recycled materials up to 75% recycled glassBREATHLR
LTABHLEMINA
LNWSATSIWE
EASY TOR
NAP OAENRGYSGEAREASAEYT
OY INRECYLDG
DAESCGADCOC2PR
TEDLOPTTHER
MALINEMHSSfiflfl
fi fi ?flfi??? fi?fiW/mK 0.031-0.036
ResidentialNew and Old
10+ YEARSEN ISO 1316
2EMS 551706 003EN ISO 9001: 2000
ISOVER SOLUTIONS GUIDE 20233
THERMAL WALL & FLOOR SOLUTIONS
STANDARDS AND
CERTIFICATION
Quality
We hold a Quality Management Standard EN ISO 9001: 2015 for manufacturing. CE All products are manufactured in accordance with the CE marking requirements under theConstruction Products Regulation
Product
StandardsAll products are manufactured in accordance with product standard: EN 13162:2012+A1:2015 and EN 13172 Evaluation of Conformity.Environment
Isover is an ISO 14001:2015 (Environmental Management System) accredited manufacturing facility. This accreditation ensures that all products are manufactured to the stringent standards set out by this management system.Indoor Air
Quality
Awarded the highest standard in indoor air quality - Euro ns Gold" Label The Gold Certi cate means that Isover mineral wool is certi ed as an outstanding material in terms of Indoor AirQuality emissions regulations.
Durability
Fire Performance Euroclass classi cation of the product is related to the organic content, which cannot increase with time. Thermal conductivity of mineral wool products does not change with time, experience has shown the bre structure to be stable and the porosity contains no other gases than atmospheric air. (See std EN13162:2012 Annex ZA,Table ZA.1) Will not accelerate corrosion with steel, copper or aluminium. Will not sustain vermin, nor breed or promote fungi or bacteria.Responsibly
Sourced Our products have been manufactured to BES60001 to ensure their constituent materials have been responsibly sourced. fi?flflISOVER SOLUTIONS GUIDE 20234
THERMAL WALL & FLOOR SOLUTIONS
FIRE PERFORMANCE
IN TIMBER FRAME BUILDINGS
JULY 1ST 2017
EN Standards instead of BS
As of July 1st 2017, new Building Regulations require re protection of structural building elements in dwellings to be assessed under EN standards instead of British Standards (BS). The EN test uses a furnace that burns hotter/faster than the national" British Standard, BS 476 which means that building elements are subject to more onerous conditions and may need higher specications as a result.This construction is specic to the relevant test evidence including loading, insulation, noggings, restopping, xing centres
and counter battens. Designers must ensure the tested system is consistent with the built construction.
** OSB sheathing to cavity. Alternatives must be based on complete & relevant re test evidence. Gyproc® plasterboard linings on example timer frame constructionMOISTURRM
BRMINAALWSTEEELLAA
LSLS WLS LL IIAALTWSWWELS
MAALWSTEEELL
AALSLSL
AALSLL
L AAL TWSW WE E ATTHH
E ATTHEATTHLHH
E ATTH HHH€EATTHL
Supplementary
Guidance to TGD B
(Fire Safety) Vol 2, 2017.Issued Sept 2020.
Guidance on Timber
Frame Walls
The build-up including
linings must be carried out in the factory for all separating walls."Free Phone (ROI): 1800 744480
Free Phone (NI): 0845 3990159
Email: tech.ie@saint-gobain.com Visit the Technical Academy for our free courses on re:For full system description, please refer to our
Timber Frame Guide or contact the Saint-Gobain
(Isover) Technical Department.ISOVER SOLUTIONS GUIDE 20235
THERMAL WALL & FLOOR SOLUTIONS
0.16 Pitched Roof
0.25 Pitched Roof
ROI1800 744480 NI
0845 399 0159 EMAIL
tech.ie@saint-gobain.comBUILDING REGULATIONS
REPUBLIC OF IRELAND
The following is a guide to thermal building regulations for new & existing dwellings, delivering comfort and energy savings through eective thermal insulation.Republic of Ireland
New Dwellings TGD - Part L - 2019
Minimum standards for U-Values
Upper limit for air permeability is 5m/(h.m)
Republic of Ireland
Existing Dwellings TGD - Part L - 2019
Minimum standards for U-Values
For more information you can contact our technical team onfree phone (ROI) 1800 744480 or go to www.isover.ieFor more information you can contact our technical team on
free phone (ROI) 1800 744480 or go to www.isover.ie0.16(pitched
roof)0.16 (attics)0.20 (at roofs)
Average
U-Value
1.40 (Doors and Windows)
0.18 (ground oors)
0.15 (with underoor heating)0.18 (other exposed oors)
0.18 (with underoor heating)
0.18 (walls)
0.18 (walls)
0.18 (walls)
0.25 (pitched roof)Average
U-Value
1.40 (Doors and Windows)
0.16 (attics)
0.25 (?at roofs)
0.45 (?oors)
0.25 (?oors)
0.35 (walls)
0.35/0.55
(walls)0.35 (walls)
ISOVER SOLUTIONS GUIDE 20236
THERMAL WALL & FLOOR SOLUTIONS
0.20 Pitched Roof
0.18 Pitched Roof
BUILDING REGULATIONS
NORTHERN IRELAND
The following is a guide to thermal building regulations for new & existing dwellings, delivering comfort and energy savings through eective thermal insulation.Northern Ireland
Existing Dwellings - DFP
Technical Booklet F1:2012
Minimum standards for U-Values
These regulations are split across
quotesdbs_dbs50.pdfusesText_50[PDF] catalogue lit en bois pdf
[PDF] catalogue marjane casablanca
[PDF] catalogue marjane septembre 2017
[PDF] catalogue metod ikea 2017
[PDF] catalogue metro boisson
[PDF] catalogue meuble bois pdf
[PDF] catalogue pax 2016
[PDF] catalogue peinture maison pdf
[PDF] catalogue points leclerc
[PDF] catalogue renault symbol pdf
[PDF] catalogue salon moderne pdf
[PDF] catalogue tiguan 2016
[PDF] catalogue tiguan 2017
[PDF] catalogue vacaf 2017 en ligne